Displaying publications 1 - 20 of 91 in total

Abstract:
Sort:
  1. de Moraes Porto IC, Honório NC, Amorim DA, de Melo Franco AV, Penteado LA, Parolia A
    J Conserv Dent, 2014 Jan;17(1):65-9.
    PMID: 24554865 DOI: 10.4103/0972-0707.124151
    The radiopacity of contemporary adhesive systems has been mentioned as the indication for replacement of restorations due to misinterpretation of radiographic images.
    Matched MeSH terms: Adhesives
  2. de Moraes IQS, do Nascimento TG, da Silva AT, de Lira LMSS, Parolia A, Porto ICCM
    Restor Dent Endod, 2020 Aug;45(3):e31.
    PMID: 32839712 DOI: 10.5395/rde.2020.45.e31
    Matrix metalloproteinases (MMPs) are enzymes that can degrade collagen in hybrid layer and reduce the longevity of adhesive restorations. As scientific understanding of the MMPs has advanced, useful strategies focusing on preventing these enzymes' actions by MMP inhibitors have quickly developed in many medical fields. However, in restorative dentistry, it is still not well established. This paper is an overview of the strategies to inhibit MMPs that can achieve a long-lasting material-tooth adhesion. Literature search was performed comprehensively using the electronic databases: PubMed, ScienceDirect and Scopus including articles from May 2007 to December 2019 and the main search terms were "matrix metalloproteinases", "collagen", and "dentin" and "hybrid layer". MMPs typical structure consists of several distinct domains. MMP inhibitors can be divided into 2 main groups: synthetic (synthetic-peptides, non-peptide molecules and compounds, tetracyclines, metallic ions, and others) and natural bioactive inhibitors mainly flavonoids. Selective inhibitors of MMPs promise to be the future for specific targeting of preventing dentin proteolysis. The knowledge about MMPs functionality should be considered to synthesize drugs capable to efficiently and selectively block MMPs chemical routes targeting their inactivation in order to overcome the current limitations of the therapeutic use of MMPs inhibitors, i.e., easy clinical application and long-lasting effect.
    Matched MeSH terms: Adhesives
  3. Zuber SH, Hashikin NAA, Mohd Yusof MF, Aziz MZA, Hashim R
    Appl Radiat Isot, 2021 Apr;170:109601.
    PMID: 33515930 DOI: 10.1016/j.apradiso.2021.109601
    Experimental particleboards are made from Rhizophora spp. wood trunk with three different percentages of lignin and soy flour (0%, 6% and 12%) as adhesives. The objective was to investigate the equivalence of Rhizophora spp. particleboard as phantom material with human soft tissue using Computed Tomography (CT) number. The linear and mass attenuation coefficient of Rhizophora spp. particleboard at low energy range was also explored using X-ray Fluorescence (XRF) configuration technique. Further characterization of the particleboard was performed to determine the effective atomic number, Zeff using Energy Dispersive X-Ray (EDX) method. Adhesive-bonded Rhizophora spp. particleboard showed close similarities with water, based on the average CT numbers, electron density calibration curve and the analysis of CT density profile, compared to the binderless particleboard. The effective atomic number obtained from the study indicated that the attenuation properties of all the particleboards at different percentages of adhesives were almost similar to water. The mass attenuation coefficient calculated from XRF configuration technique showed good agreement with water from XCOM database, suggesting its potential as phantom material for radiation study.
    Matched MeSH terms: Adhesives
  4. Yap FC, Wong WL, Maule AG, Brennan GP, Chong VC, Lim LH
    Sci Rep, 2017 Mar 22;7:44980.
    PMID: 28327603 DOI: 10.1038/srep44980
    Although there have been extensive studies on the larval adhesion of acorn barnacles over the past few decades, little is known about stalked barnacles. For the first time, we describe the larval adhesive systems in the stalked barnacle, Octolasmis angulata and the findings differ from previous reports of the temporary (antennulary) and cement glands in thoracican barnacles. We have found that the temporary adhesives of cyprid are produced by the clustered temporary adhesive glands located within the mantle, instead of the specialised hypodermal glands in the second antennular segment as reported in the acorn barnacles. The temporary adhesive secretory vesicles (TASV) are released from the gland cells into the antennule via the neck extensions of the glands, and surrounded with microtubules in the attachment disc. Cement glands undergo a morphological transition as the cyprid grows. Synthesis of the permanent adhesives only occurs during the early cyprid stage, and is terminated once the cement glands reach maximum size. Evidence of the epithelial invaginations on the cement glands supports the involvement of exocytosis in the secretion of the permanent adhesives. This study provides new insight into the larval adhesives system of thoracican barnacles.
    Matched MeSH terms: Adhesives/chemistry*
  5. Yanti Johari, Zaihan Ariffin, Haslina Taib, Norehan Mokhtar
    MyJurnal
    Resin-bonded fibre-reinforced composite bridges provide many advantages over the conventional
    bridges or implant treatment in the management of a traumatically or congenitally missing anterior tooth.
    Furthermore, there is an increasing demand towards providing a metal free resin-bonded bridges over the alloybased
    restorations in order to meet the aesthetic needs especially in the anterior region. Advances in the
    adhesive technology and tooth colored materials offer improved bonding system and better aesthetic outcome.
    Nevertheless, careful selection of cases to receive this type of approach is also one of the key factor to ensure
    the clinical survival of fibre-reinforced composite bridges. This report aims to present the use of fibre-reinforced
    composite to construct indirect cantilever fibre-reinforced composite bridges as part of minimum intervention
    dentistry.
    Matched MeSH terms: Adhesives
  6. Yahya, N.A., Lui, J.L., Chong, K.W.A., Abu Kasim, N.H., Radzi, Z., Lim, C.M.
    Ann Dent, 2008;15(1):11-19.
    MyJurnal
    The objective of this study was to investigate the effect of various luting cement systems on bond strength of fibre-reinforced posts to root canal dentine. 40 extracted single rooted sound premolar teeth were root filled, decoronated and randomly divided into four groups. Fibre posts, Aestheti- Plus™ (Bisco,Inc. Schaumburg, IL, USA) were cemented using four luting cements: Group A (control): Elite 100® Zinc phosphate (GC Corp, Japan), Group B: Calibra ™ Esthetic Resin Cement (Dentsply Caulk, USA), Group C: RelyX ARC Adhesive Resin (3M ESPE), Group D: RelyX Unicem Aplicap (3M ESPE). Each root was sliced into 2 discs representing the coronal and middle portions of the root canal giving rise to 20 specimens per group. Bond strength was determined using push-out tests and data was analyzed using SPSS version 14.0. The mean bond strength of Group A to Aestheti-Plus™ post was 7.71 MPa (±2.51) and Group B was 5.69 MPa (±3.23). Group C exhibited the lowest mean bond strength, 4.29 MPa (±3.53) while the highest bond strength was obtained from Group D, 7.98 MPa (±2.61). One way ANOVA showed significant interaction between all groups (p=.OOI). Post-hoc Bonferroni test reve;iled that bond strength of Group C was significantly lower compared to Group A (p=.008) and D (p=.004). In conclusion, the mean bond strength of Aestheti- Plus™ post to root canal dentine was highest when cemented with RelyX Unicem resin cement followed by Elite 100® zinc phosphate cement, Calibra and RelyX ARC resin cements. However, the bond strengths of Cali bra and RelyX Unicem resin cements were not significantly different from Elite 100® zinc phosphate cement.
    Matched MeSH terms: Adhesives
  7. Xue YT, Chen MY, Cao JS, Wang L, Hu JH, Li SY, et al.
    Mil Med Res, 2023 Mar 23;10(1):15.
    PMID: 36949519 DOI: 10.1186/s40779-023-00451-1
    BACKGROUND: Reconstruction of damaged tissues requires both surface hemostasis and tissue bridging. Tissues with damage resulting from physical trauma or surgical treatments may have arbitrary surface topographies, making tissue bridging challenging.

    METHODS: This study proposes a tissue adhesive in the form of adhesive cryogel particles (ACPs) made from chitosan, acrylic acid, 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The adhesion performance was examined by the 180-degree peel test to a collection of tissues including porcine heart, intestine, liver, muscle, and stomach. Cytotoxicity of ACPs was evaluated by cell proliferation of human normal liver cells (LO2) and human intestinal epithelial cells (Caco-2). The degree of inflammation and biodegradability were examined in dorsal subcutaneous rat models. The ability of ACPs to bridge irregular tissue defects was assessed using porcine heart, liver, and kidney as the ex vivo models. Furthermore, a model of repairing liver rupture in rats and an intestinal anastomosis in rabbits were established to verify the effectiveness, biocompatibility, and applicability in clinical surgery.

    RESULTS: ACPs are applicable to confined and irregular tissue defects, such as deep herringbone grooves in the parenchyma organs and annular sections in the cavernous organs. ACPs formed tough adhesion between tissues [(670.9 ± 50.1) J/m2 for the heart, (607.6 ± 30.0) J/m2 for the intestine, (473.7 ± 37.0) J/m2 for the liver, (186.1 ± 13.3) J/m2 for muscle, and (579.3 ± 32.3) J/m2 for the stomach]. ACPs showed considerable cytocompatibility in vitro study, with a high level of cell viability for 3 d [(98.8 ± 1.2) % for LO2 and (98.3 ± 1.6) % for Caco-2]. It has comparable inflammation repair in a ruptured rat liver (P = 0.58 compared with suture closure), the same with intestinal anastomosis in rabbits (P = 0.40 compared with suture anastomosis). Additionally, ACPs-based intestinal anastomosis (less than 30 s) was remarkably faster than the conventional suturing process (more than 10 min). When ACPs degrade after surgery, the tissues heal across the adhesion interface.

    CONCLUSIONS: ACPs are promising as the adhesive for clinical operations and battlefield rescue, with the capability to bridge irregular tissue defects rapidly.

    Matched MeSH terms: Adhesives*; Tissue Adhesives*
  8. Wong CF, Yuen KH, Peh KK
    Int J Pharm, 1999 Mar 25;180(1):47-57.
    PMID: 10089291
    A method using a texture analyzer equipment and chicken pouch as the biological tissue was investigated for measuring the bioadhesive properties of polymers under simulated buccal conditions. The method was evaluated using two polymers, namely Carbopol 974P and Methocel K4M while the instrument variables studied included the contact force, contact time and speed of withdrawal of the probe from the tissue. The parameters measured were the work of adhesion and peak detachment force. Longer contact time and faster probe speed not only gave better reproducibility of results, but also better sensitivities for both parameters measured. On the other hand, a certain level of contact force was found essential for achieving good bioadhesion, above which there was no further contribution to the bioadhesion process. When the method was applied to determine the bioadhesiveness of several polymers, the values obtained for the work of adhesion and peak detachment force were quite consistent in the ranking of the polymers. The Carbopols were found to have the highest values, followed by gelatin, sodium carboxymethyl celluloses and hydroxypropylmethyl celluloses. On the other hand, Alginic acid, Eudragit RLPO and RSPO, and Chitosan appeared to have low bioadhesive values.
    Matched MeSH terms: Adhesives*
  9. Win, S. Y., Win, T. T., Maung, Y. M., Soe, K. K. K., Kyaw, T. T., Tan, C. K., et al.
    MyJurnal
    Dye-sensitized solar cell (DSSC) is the third generation of thin film solar cell. In this work, carrot fruit dye was prepared and used in DSSC as a sensitizer. TiO2–ZrO2 fine binary oxide was mechanochemically prepared and made paste. TiO2–ZrO2 paste (colloidal) was deposited onto FTO/glass in two ways, i.e. as single and double coatings by rolling method. It was immersed in the carrot solution to get dyed cell. The dyed TiO2-ZrO2-FTO/glass cell was offset with the FTO/glass cell coated with adhesive carbon paste. Photovoltaic properties of prepared TiO2–ZrO2 DSSC cell were measured. Results showed that the efficiency of double coating cell was greater than that of the single coating cell. According to the fill factor from the experiments, both the DSSC cells were acceptable for industrial requirement. Hence, it can be concluded that the results obtained were acceptable in the use of cost-effective and eco-favourable dye-sensitized solar cell.
    Matched MeSH terms: Adhesives
  10. Vakili AH, Selamat MR, Moayedi H
    ScientificWorldJournal, 2013;2013:547615.
    PMID: 23864828 DOI: 10.1155/2013/547615
    Use of dispersive clay as construction material requires treatment such as by chemical addition. Treatments to dispersive clay using pozzolan and Portland cement, singly and simultaneously, were carried out in this study. When used alone, the optimum amount of pozzolan required to treat a fully dispersive clay sample was 5%, but the curing time to reduce dispersion potential, from 100% to 30% or less, was 3 month long. On the other hand, also when used alone, a 3% cement content was capable of reducing dispersion potential to almost zero percent in only 7 days; and a 2% cement content was capable of achieving similar result in 14 days. However, treatment by cement alone is costly and could jeopardize the long term performance. Thus, a combined 5% pozzolan and 1.5% cement content was found capable of reducing dispersion potential from 100% to zero percent in 14 days. The results indicate that although simultaneous treatment with pozzolan and cement would extend the required curing time in comparison to treatment by cement alone of a higher content, the task could still be carried out in a reasonable period of curing time while avoiding the drawbacks of using either pozzolan or cement alone.
    Matched MeSH terms: Adhesives/chemistry*
  11. Teoh MK, Bucknall TE
    Med J Malaysia, 1989 Jun;44(2):122-8.
    PMID: 2696870
    The use of tissue adhesives has been widely studied since the 1960s. Since then they have found use in specialties like plastic surgery, neurosurgery, ENT surgery and dental surgery. Several papers have reported their safe use, both clinically and experimentally, particularly of the newer homologue n-butyl/2-cyanoacrylate (Histoacryl). In this study 43 patients (46 wounds) whose operations involved a groin incision were randomised into two groups for skin closure either with Dexon subcuticular suture (23 wounds) or Histoacryl glue (23 wounds). We found that both sets of wounds healed well with no wound infections or excessive inflammation when assessed at one week and four weeks. However the glued wounds had consistently better cosmesis scores (mean score 4.71 at four weeks) compared to the subcuticular Dexon wounds (mean score 4.00 at four weeks) and P value of less than 0.05. We feel that there is a place for tissue adhesives in skin closure for some general surgical wounds.
    Matched MeSH terms: Tissue Adhesives/therapeutic use*
  12. Teoh LY, Chong SS, Hoh SY, Teoh MS, Ng KL
    Asian J Surg, 2019 May;42(5):634-640.
    PMID: 30446424 DOI: 10.1016/j.asjsur.2018.09.014
    OBJECTIVES: Monofilament sutures, both absorbable and non-absorbable, have been used for wound closure. Tissue adhesive has been used in closure of clean, low tension wounds. However, there have been very few published studies on the aesthetic outcomes in neck surgeries. The aim of this study is to compare the patients' and doctors' satisfaction scores in the aesthetic outcome between both methods of closure of thyroidectomy wounds using validated scoring systems.

    METHODS: A double-blinded randomised controlled trial comparing the aesthetic outcome between tissue adhesive and conventional suture was conducted among patients undergoing thyroid and parathyroid surgeries. Ninety-six patients were randomised into two treatment groups. Patients' wounds were scored by an independent observer using the SBSES score at 6 weeks postoperatively and observer component of the POSAS score at 3 months.

    RESULTS: Forty-nine patients were randomised to the tissue adhesive group while forty-seven patients received the conventional method. There was no statistical difference in the aesthetic outcome using the patient's scoring system between both arms, with a median score of 9 (p = 0.25, SD ± 6.5). The observer's satisfaction score using POSAS was also not statistically significant (median score of 14 (p = 0.77, SD ± 6.2)). No significance was found in the observer's median score using the SBSES scoring system either (score 3, p = 0.12, SD ± 1.3). However, there was significant reduction in the duration of closure using glue (4.42 mins vs 6.36 mins, p 

    Matched MeSH terms: Tissue Adhesives*
  13. Tee YN, Kumar PV, Maki MAA, Elumalai M, Rahman SAKMEH, Cheah SC
    Curr Pharm Biotechnol, 2021;22(7):969-982.
    PMID: 33342408 DOI: 10.2174/1389201021666201218124450
    BACKGROUND: Recombinant Keratinocyte Growth Factor (rHuKGF) is a therapeutic protein used widely in oral mucositis after chemotherapy in various cancers, stimulating lung morphogenesis and gastrointestinal tract cell proliferation. In this research study, chitosan-rHuKGF polymeric complex was implemented to improve the stability of rHuKGF and used as rejuvenation therapy for the treatment of oral mucositis in cancer patients.

    OBJECTIVE: Complexation of rHuKGF with mucoadhesive low molecular weight chitosan to protect rHuKGF from proteolysis and investigate the effect of chitosan-rHuKGF complex on the proliferation rate of FHs 74 Int cells.

    METHODS: The interaction between chitosan and rHuKGF was studied by molecular docking. Malvern ZetaSizer Nano Zs and Fourier-Transform Infrared spectroscopy (FTIR) tests were carried out to characterize the chitosan-rHuKGF complex. In addition, SDS-PAGE was performed to investigate the interaction between chitosan-rHuKGF complex and pepsin. The effect of chitosan-rHuKGF complex on the proliferation rate of FHs 74 Int cells was studied by MTT assay.

    RESULTS: Chitosan-rHuKGF complex was formed through the hydrogen bonding proven by the docking studies. A stable chitosan-rHuKGF complex was formed at pH 4.5 and was protected from proteolysis and assessed by SDS PAGE. According to the MTT assay results, chitosan-rHuKGF complex increased the cell proliferation rate of FHs 74 Int cells.

    CONCLUSION: The developed complex improved the stability and the biological function of rHuKGF.

    Matched MeSH terms: Adhesives/metabolism; Adhesives/pharmacology; Adhesives/chemistry*
  14. Tan HL, Nah SA, Budianto II, Sehat S, Tamba R
    J Pediatr Surg, 2012 Dec;47(12):2294-7.
    PMID: 23217892 DOI: 10.1016/j.jpedsurg.2012.09.022
    Octyl cyanoacrylate has been used for many years for simple skin closure, but its use in hypospadias repair and as a urethral stent fixator has not been previously reported. We report our experience.
    Matched MeSH terms: Tissue Adhesives/therapeutic use*
  15. Tan EW, Tan KY, Phang LV, Kumar PV, In LLA
    PLoS One, 2019;14(7):e0219912.
    PMID: 31335895 DOI: 10.1371/journal.pone.0219912
    Vaccine administration via the oral route is preferable to parenteral routes due to ease of administration. To date, most available oral vaccines comprises of live attenuated pathogens as oppose to peptide-based vaccines due to its low bioavailability within the gastrointestinal (GI) tract. Over the years, probiotic-based peptide delivery vehicles comprising of lactic acid bacteria such as Lactococcus lactis has emerged as an interesting alternative due to its generally recognized as safe (GRAS) status, a fully sequenced genome, transient gut colonization time, and is an efficient cellular factory for heterologous protein production. However, its survivability through the GI tract is low, thus better delivery approaches are being explored to improve its bioavailability. In this study, we employ the incorporation of a double coated mucoadhesive film consisting of sodium alginate and Lycoat RS 720 film as the inner coat. The formulated film exhibits good mechanical properties of tensile strength and percent elongation for manipulation and handling with an entrapment yield of 93.14±2.74%. The formulated mucoadhesive film is subsequently loaded into gelatin capsules with an outer enteric Eudragit L100-55 coating capable of a pH-dependent breakdown above pH 5.5 to protect against gastric digestion. The final product and unprotected controls were subjected to in vitro simulated gastrointestinal digestions to assess its survivability. The product demonstrated enhanced protection with an increase of 69.22±0.67% (gastric) and 40.61±8.23% (intestinal) survivability compared to unprotected controls after 6 hours of sequential digestion. This translates to a 3.5 fold increase in overall survivability. Owing to this, the proposed oral delivery system has shown promising potential as a live gastrointestinal vaccine delivery host. Further studies involving in vivo gastrointestinal survivability and mice immunization tests are currently being carried out to assess the efficacy of this novel oral delivery system in comparison to parenteral routes.
    Matched MeSH terms: Adhesives/chemistry
  16. Talib AAA, Jumahat A, Jawaid M, Sapiai N, Leao AL
    Materials (Basel), 2021 Feb 02;14(3).
    PMID: 33540915 DOI: 10.3390/ma14030701
    Basalt fibre is a promising mineral fibre that has high potential to replace synthetic based glass fibre in today's stringent environmental concern. In this study, friction and wear characteristics of glass and basalt fibres reinforced epoxy composites were studied and comparatively evaluated at two test stages. The first stage was conducted at fixed load, speed and distance under three different conditions; adhesive, abrasive and erosive wear, wherein each composite specimens slide against steel, silicon carbide, and sand mixtures, respectively. The second stage was conducted involving different types of adhesive sliding motions against steel counterpart; unidirectional and reciprocating motion, with the former varied at pressure-velocity (PV) factor; 0.23 MPa·m/s and 0.93 MPa·m/s, while the latter varied at counterpart's configuration; ball-on-flat (B-O-F) and cylinder-on-flat (C-O-F). It was found that friction and wear properties of composites are highly dependent on test conditions. Under 10 km test run, Basalt fibre reinforced polymer (BFRP) composite has better wear resistance against erosive sand compared to Glass fibre reinforced polymer (GFRP) composite. In second stage, BFRP composite showed better wear performance than GFRP composite under high PV of unidirectional sliding test and under B-O-F configuration of reciprocating sliding test. BFRP composite also exhibited better friction properties than GFRP composite under C-O-F configuration, although its specific wear rate was lower. In scanning electron microscopy examination, different types of wear mechanisms were revealed in each of the test conducted.
    Matched MeSH terms: Adhesives
  17. Sulong MZ, Setchell DJ
    J Prosthet Dent, 1991 Dec;66(6):743-7.
    PMID: 1805022
    Adhesive bond strength studies for the tray adhesive of an addition vinyl polysiloxane (President) impression material were conducted with an acrylic resin, chromium-plated brass, and plastic trays. Tensile and shear stress studies were performed on the Instron Universal testing machine. Acrylic resin specimens roughened with 80-grit silicon carbide paper exhibited appreciably higher bond strengths compared with different types of tray material and methods of surface preparation.
    Matched MeSH terms: Adhesives/chemistry*
  18. Sulaiman S, Yunus H, Sohadi R
    Med Vet Entomol, 1987 Jul;1(3):273-8.
    PMID: 2979541
    1. Seven types of water-insoluble adhesives were evaluated in sticky traps for collecting adults of Musca domestica L. and Chrysomya megacephala (Fabricius) or mosquito larvae (Aedes aegypti (L.) and Culex quinquefasciatus Say). 2. Adhesive viscosity affected the tackiness of the glues and this determined their trapping efficiency in air or water. 3. From the 'Hyvis' range of adhesives tested, 'Hyvis 200' was most effective for trapping adult flies. 4. With 24 h exposure to fourth instar Ae.aegypti larvae in tapwater, submerged plates coated with 'Hyvis 10', 'Hyvis 30' or 'Hyvis 200' formulations trapped the majority of larvae. In polluted water the highest rates of trapping were 17.3% of Ae.aegypti and 18.7% of Cx quinquefasciatus with 'Hyvis 200'. Floating traps were consistently less productive than submerged traps under laboratory conditions. 5. In a heavily polluted natural breeding-site of Cx quinquefasciatus, floating traps were more productive than submerged sticky traps with four of seven adhesives tested, the most efficient being 'Hyvis 200' (4.2 mosquitoes per hour) and Hyvis:polyethylene 90:10 (4.5/h). Despite the relative inefficiency of aquatic traps, emergent adults, pupae and second to fourth instars of larvae were collected quickly from the habitat.
    Matched MeSH terms: Adhesives*
  19. Sulaiman O, Hashim R, Wahab R, Ismail ZA, Samsi HW, Mohamed A
    Bioresour Technol, 2006 Dec;97(18):2466-9.
    PMID: 16524726
    Studies were carried out on heat treatment of bamboo species Gigantochloa scortechinii Gamble using palm oil. The samples were laminated and glued. The adhesion results showed that the delamination of glue line increased as the temperature and duration of oil heat treatment increased. Maximum load and shear strength of the glue line reduced as the heat treatment become more severe. It was found that the palm oil used as the heating medium penetrated in some parts of the cell wall as well as in the cell lumen of the bamboo.
    Matched MeSH terms: Adhesives
  20. Soubam T, Gupta A, Jamari SS
    Environ Sci Pollut Res Int, 2023 Dec;30(60):124610-124618.
    PMID: 35610450 DOI: 10.1007/s11356-022-20788-9
    Synthetic adhesives used in the production of plywood are a matter of concern because of the emission of carcinogenic gas formaldehyde, increased environmental pollution, and the depletion of fossil fuels. In this study, a bioadhesive composed of natural rubber latex (NRL) and rice starch was developed. However, rice starch has low moisture resistance, resulting in low adhesion. Thus, to enhance the effectiveness of NRL-blended rice starch-based bioadhesive, rice starch was cross-linked with polymeric 4,4″-diphenylmethane diisocyanate (pMDI) resin, which is an environment-friendly, formaldehyde free, and moisture resistant that is highly compatible with starch. The chemical interaction, viscosity, solid content, and gel time of the developed NRL-isocyanate cross-linked rice starch-based bioadhesive was investigated. The efficacy of the formulated bioadhesive was demonstrated by the fabrication of plywood. The presence of isocyanate and urethane capabilities in the bioadhesive formulations was confirmed by Fourier transform infrared spectroscopy (FTIR). The bioadhesive type Iso-A was discovered to have the highest viscosity of 8270 mPa.s, whereas Iso-B has the shortest gel time of 3.46 min and the highest solid content of 44%; the higher solid content accelerates the gel time. In terms of physical and mechanical properties of plywood, Iso-B has the lowest thickness swelling (TS) value of 13%, lowest water absorption (WA) value of 52% and shear strength value of 1.92 MPa, which corresponds to the ISO 12466-2-2007 standard requirements. Based on the results, NRL-blended isocyanate starch-based bioadhesive could be a good potential raw material for eco-friendly plywood industries with adequate accuracy.
    Matched MeSH terms: Adhesives/chemistry
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links