METHODOLOGY: STROBE guidelines were used to design a study using 60 periodontal ligament samples obtained from healthy lower premolars where extraction was indicated for orthodontic reasons. Prior to extraction 40 of these premolars were equally divided into four groups and root canals were prepared using different systems: Mtwo, Reciproc Blue, HyFlex EDM and Plex-V. Ten premolars were prepared with hand files and served as a positive control group. The remaining 10 premolars where extracted without treatment and served as a negative control group. All periodontal ligament samples were processed to measure the expression of SP, CGRP and their receptors by radioimmunoassay. Kruskal-Wallis and Duncan tests were performed to determine statistically significant differences between the groups for each variable.
RESULTS: Greater expression of all the peptides measured were found in the hand-file preparation group, followed by the Reciproc Blue, Mtwo, HyFlex EDM and Plex-V groups. The lower SP, CGRP and their receptors values were for the intact teeth control group. Kruskal-Wallis test showed statistically significant differences amongst groups (p
MATERIALS AND METHODS: A cross-sectional study was conducted to evaluate the perceptions of nurses (n = 45) and students (n = 6) when performing patient transfers from bed to wheelchair and vice versa using the NEAR-1 compared to an existing floor lift, walking belt, and manual transfer. Participants filled out surveys evaluating the perceived task demands and usability of the NEAR-1, as well as open-ended interviews.
RESULTS: The use of the NEAR-1 significantly reduced the mean of all NASA-TLX constructs (p
MATERIALS AND METHODS: Sixty single-rooted permanent human teeth were chosen after considering the inclusion and exclusion criteria. The teeth were divided into two groups (n = 30). The test group was instrumented with TN files and the other with XPS according to manufacturer's instructions. CBCT images were taken before and after instrumentation to record the root canal distances from mesial, distal, buccal, and lingual borders of the root at 3, 5, and 7 mm distances from the root apex using a specific formula. Statistical analysis was done using the Statistical Package for the Social Sciences software program, version 20.0. The data were analyzed using the unpaired t test.
RESULTS: Both TN and XPS were safe for use in oval-shaped canals with moderate root curvature. However, the XPS showed higher buccolingual transportation as compared with TN at 3 mm from the apex and higher mesiodistal transportation at 3 and 5 mm levels from the apex as compared with TN.
CONCLUSION: Canal transportation has been detected in both systems; however, the values obtained were within the safe range (<0.3 mm). Overall, no significant difference was observed between TN and XPS (p > 0.05) in their canal transportation tendencies and centering ability.
CLINICAL SIGNIFICANCE: The study assesses the canal centering and transportation tendencies of the recently launched TN rotary system in extracted teeth with a combination of morphologies. The findings of the study are significant clinically as minimum transportation of the canal, minimal dentin removal, efficient disinfection, and three-dimensional obturation of the root canal are considered important factors in deciding the prognosis of endodontic therapy.
AIMS: The aim of this study was to look into the current perceptions and awareness about file separation during endodontic treatment among the dental house officers (DHOs).
MATERIALS AND METHODS: A novel validated questionnaire comprising of 15 close-ended questions was distributed anonymously via Google Forms through email to 1100 DHOs across Pakistan. The questionnaire consisted of two parts: the first component (Section I) collected demographic data and the second component (Section II) investigated the causes of EFS during root canal treatment. Following the completion of socioeconomic information, including age and gender, the DHOs were asked to answer a few questions about the various reasons for endodontic instrument fracture.
RESULTS: A total of 800 responses were recorded, with an effective rate of 72.8%. The majority of the DHOs (p value < 0.001) perceived that endodontic instrument fracture occurred in the posterior (61.5%) and apical third of the canal (50.5%) and in older permanent dentition (67.3%), possibly due to patient anxiety (62%). Better choice of instrument (61.15%), operators' experience (95.3%), knowledge (87.5%), and proper root canal cleaning (91.1%) are believed to be the vital steps in reducing endodontic file separation/fracture. Furthermore, majority of them (p value < 0.001) perceived that stainless steel was a superior alloy for filing instruments. Manual files tend to be more prone to fractures due to repeated use than rotary files.
CONCLUSION: This study demonstrated that young DHOs had adequate knowledge and awareness regarding the potential predisposing factors and handling techniques for EFS. This study thereby provides an evaluating tool to access the insights of the current perceptions and awareness of DHOs concerning EFS.
METHODS: This study, involving a series of N-of-1 trials, included 21 participants who had a history of neuropathic plantar forefoot ulcers. Participants were recruited from two public hospitals and one private podiatry clinic in Sydney, New South Wales, Australia. This trial is non-randomised and unblinded. Participants will be recruited from three sites, including two high-risk foot services and a private podiatry clinic in Sydney, Australia. Mobilemat™ and F-Scan® plantar pressure mapping systems by TekScan® (Boston, USA) will be used to measure barefoot and in-shoe plantar pressures. Participants' self-reports will be used to quantify the wearing period over a certain period of between 2 and 4 weeks during the trial. Participant preference toward footwear, insole design and quality-of-life-related information will be collected and analysed. The descriptive and inferential statistical analyses will be performed using IBM SPSS Statistics (version 27). And the software NVivo (version 12) will be utilised for the qualitative data analysis.
DISCUSSION: This is the first trial assessing footwear and insole interventions in people with diabetes by using a series of N-of-1 trials. Reporting self-declared wearing periods and participants' preferences on footwear style and aesthetics are the important approaches for this trial. Patient-centric device designs are the key to therapeutic outcomes, and this study is designed with that strategy in mind.
TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry (ANZCTR) ACTRN12620000699965p. Registered on June 23, 2020.
DESIGN: For each participant, the output of the initial hearing aid fitting was compared to DSL v5.0 Child prescriptive targets and again after the fitting was adjusted using coupler-based verification and RECD measures. Outcomes for initial and adjusted fittings were examined using the Speech Intelligibility Index (SII), Parent's Evaluation of Aural/Oral Performance of Children (PEACH) rating scale, and speech perception tests in quiet and noise.
STUDY SAMPLE: Sixty-eight children aged 3 months to 17 years with moderate to profound hearing loss participated in the study.
RESULTS: Fit-to-targets improved significantly after hearing aids were adjusted to match targets to within 5 dB RMSE. Adjusted hearing aids provided increased aided audibility compared to initial fittings and resulted in improved speech perception scores and parent-reported hearing performance. Fifty percent of the children aged 6 to 17 years preferred their adjusted fitting compared to 10% who preferred their initial fitting.
CONCLUSIONS: Improvement in fit-to-target to a validated paediatric prescriptive formula using best practice procedures can result in improved auditory outcomes and possible self-reported satisfaction.
METHODS: We analysed the total visits and discharge rates during periods of using the nebulizer and current pMDI-VMMS methods. The acceptance of pMDI-VMMS by patients and assistant medical officers (AMOs) were assessed by questionnaire.
RESULTS AND DISCUSSION: We analysed 3184 ED visits and responses from 103 patients and 32 AMOs. The direct discharge rate was similar for both nebulizer (n = 2162, 92.5%) and pMDI-VMMS method (n = 768, 90.7%) (p-value = 0.120). Twenty-eight patients (27.2%) favoured the pMDI-VMMS over the nebulizer, whereas 36 patients (35.0%) had no preference for either method. Sixty-four patients (62.1%) felt that the current pMDI-VMMS method was better or at least as effective in relieving their symptoms as a nebulizer. The current method was favoured over the nebulizer by twenty-seven AMOs (84.4%). Twenty-eight (87.5%) AMOs suggested that the current method was more effective than the nebulizer.
WHAT IS NEW AND CONCLUSION: The bronchodilator delivered via pMDI-VMMS appeared to be comparable to nebulizer in treating mild to moderate asthma and COPD exacerbations in the outpatient ED. Most patients and AMOs accepted the use of pMDI-VMMS in the outpatient ED during the current COVID-19 pandemic. The Venturi mask modified spacer can be a cheap and effective alternative to the commercial spacer in a resource-limited situation.