METHODS: An international, multidisciplinary panel of 23 experts in orbital tumor surgery was formed. A modified Delphi method was used to develop the cavernous hemangioma exclusively endonasal resection (CHEER) staging system with a total of 2 rounds being completed.
RESULTS: Tumors medial to a plane along the long axis of the optic nerve may be considered amenable for an exclusively endonasal resection. In select cases, tumors may extend inferolaterally if the tumor remains below a plane from the contralateral naris through the long axis of the optic nerve (ie, plane of resectability [POR]). This definition reached consensus with 91.3% of panelists in agreement. Five stages were designed based on increasing technical resection difficulty and potential for morbidity. Stages were based on the relationship of the tumor to the extraocular muscles, the inferomedial muscular trunk of the ophthalmic artery (IMT), and orbital foramina. Staging by anatomic location also reached consensus with 87.0% of panelists in agreement. Size was not included in the staging system due to the lack of agreement on the contribution of size to resection difficulty.
CONCLUSION: Endoscopic orbital tumor surgery is a nascent field with a growing, yet heterogeneous, body of literature. The CHEER staging system is designed to facilitate international, high-quality, standardized studies establishing the safety, efficacy, and outcomes of endonasal resection of OCH.
OBJECTIVES: To evaluate and compare the depth and distances from various points of the orbital rim to the fissures and foramina of the orbital apex between genders in the local population.
METHODOLOGY: Linear measurements were conducted on 60 orbits from 30 patients who had undergone head computed tomography scan. These measurements were done utilizing the multiplanar reconstruction modes on computed tomography images with minimum slice thickness of 1 mm.
RESULTS: Males have statistically significant larger orbits than females with higher mean measurements in all parameters, except for the distance from posterior ethmoidal foramen to the optic canal which was the same. However, there were no significant differences in all parameters between the right and left orbits.
CONCLUSION: This study provides the absolute limit of safe internal orbital dissection in respect to the local population. Despite males having larger orbits than females, it is clinically negligible.
RESULTS: In each group, there were 12 males (60%) and average age was not significantly different (p = 0.682-0.987). Using Chinese subjects as a reference, in Chinese, Malay, Indian and Caucasian subjects, mean trigone thickness was 13.68, 14.02, 11.60 (p orbital depth was 27.54, 24.97, 22.12 (p = 0.001) and 25.93 mm and diagonal orbital depth was 34.19, 33.27, 29.48 (p = 0.01) and 34.63 mm respectively.
CONCLUSIONS: Indian and, to a lesser extent, Caucasian subjects have smaller trigones compared to their Chinese and Malay counterparts. Indian subjects also have shallower orbits and due care should be taken during decompression surgery.