  1. Ho JPY, Merican AM, Hashim MS, Abbas AA, Chan CK, Mohamad JA
    J Arthroplasty, 2017 10;32(10):3176-3183.
    PMID: 28579444 DOI: 10.1016/j.arth.2017.04.060
    BACKGROUND: The posterior tibial slope (PTS) is an important consideration in knee arthroplasty. However, there is still no consensus for the optimal slope. The objectives of this study were (1) to reliably determine the native PTS in this population using 3-dimensional computed tomography scans and (2) to determine the normal reference range for PTS in this population.

    METHODS: One hundred computed tomography scans of disease-free knees were analyzed. A 3-dimensional reconstructed image of the tibia was generated and aligned to its anatomic axis in the coronal and sagittal planes. The tibia was then rotationally aligned to the tibial plateau (tibial centroid axis) and PTS was measured from best-fit planes on the surface of the proximal tibia and individually for the medial and lateral plateaus. This was then repeated with the tibia rotationally aligned to the ankle (transmalleolar axis).

    RESULTS: When rotationally aligned to the tibial plateau, the mean PTS, medial PTS, and lateral PTS were 11.2° ± 3.0 (range, 4.7°-17.7°), 11.3° ± 3.2 (range, 2.7°-19.7°), and 10.9° ± 3.7 (range, 3.5°-19.4°), respectively. When rotationally aligned to the ankle, the mean PTS, medial PTS, and lateral PTS were 11.4° ± 3.0 (range, 5.3°-19.3°), 13.9° ± 3.7 (range, 3.1°-24.4°), and 9.7° ± 3.6 (range, 0.8°-17.7°), respectively.

    CONCLUSION: The PTS in the normal Asian knee is on average 11° (mean) with a reference range of 5°-17° (mean ± 2 standard deviation). This has implications to surgery and implant design.

    Matched MeSH terms: Tomography, X-Ray Computed/methods; Imaging, Three-Dimensional/methods
  2. Menon PS, Said FA, Mei GS, Berhanuddin DD, Umar AA, Shaari S, et al.
    PLoS One, 2018;13(7):e0201228.
    PMID: 30052647 DOI: 10.1371/journal.pone.0201228
    This work investigates the surface plasmon resonance (SPR) response of 50-nm thick nano-laminated gold film using Kretschmann-based biosensing for detection of urea and creatinine in solution of various concentrations (non-enzymatic samples). Comparison was made with the presence of urease and creatininase enzymes in the urea and creatinine solutions (enzymatic samples), respectively. Angular interrogation technique was applied using optical wavelengths of 670 nm and 785 nm. The biosensor detects the presence of urea and creatinine at concentrations ranging from 50-800 mM for urea samples and 10-200 mM for creatinine samples. The purpose of studying the enzymatic sample was mainly to enhance the sensitivity of the sensor towards urea and creatinine in the samples. Upon exposure to 670 nm optical wavelength, the sensitivity of 1.4°/M was detected in non-enzymatic urea samples and 4°/M in non-enzymatic creatinine samples. On the other hand, sensor sensitivity as high as 16.2°/M in urea-urease samples and 10°/M in creatinine-creatininase samples was detected. The enhanced sensitivity possibly attributed to the increase in refractive index of analyte sensing layer due to urea-urease and creatinine-creatininase coupling activity. This work has successfully proved the design and demonstrated a proof-of-concept experiment using a low-cost and easy fabrication of Kretschmann based nano-laminated gold film SPR biosensor for detection of urea and creatinine using urease and creatininase enzymes.
    Matched MeSH terms: Clinical Chemistry Tests/methods; Surface Plasmon Resonance/methods
  3. Hung SKY, Hiew FL, Viswanathan S, Puvanarajah S
    J Peripher Nerv Syst, 2018 Sep;23(3):183-189.
    PMID: 30027593 DOI: 10.1111/jns.12282
    Intravenous immunoglobulin (IVIG), corticosteroids and therapeutic plasma exchange (TPE) are evidence-based conventional treatments for chronic inflammatory demyelinating polyneuropathy (CIDP). In many centres, unconventional treatments are frequently used as alternatives. We evaluated the outcome of conventional and unconventional therapies in 31 CIDP patients. Overall response rate with conventional first-line immunotherapies was 77% (20/26), comparable between IVIG and corticosteroids (80% vs 70%). Use of TPE was limited. Treatment response among typical and atypical CIDP were comparable (76 vs 80%). Non-responders were patients with progressive form of typical CIDP and DADS. Majority (21/26, 81%) of patients with persistent neurological deficits received maintenance therapy. Two subgroups of patients frequently treated with maintenance immunosuppressants were those with improving or stable disease following first-line treatment (12, 57%) and those with progressive form of CIDP (2, 10%). Primary indications for immunosuppressant use were corticosteroids-sparing and additional immunosuppression effects. Nine (64%) patients with improving or stable disease given azathioprine were taken off corticosteroids after a median duration of 14 months (range 12-108). Two (14%) eventually achieved cure or clinical remission without treatment. Maintenance IVIg was given to 6 (29%) relapsing CIDP patients; none of achieved cure or remission after similar median duration of treatment. Less potent immunosuppressant drugs (azathioprine, mycophenolate mofetil, and methotrexate) were frequently used, with moderate adverse effect profiles. In resource limited setting, unconventional treatments were commonly used among CIDP patients with different clinical course of progression. In most cases, careful risk-benefit re-assessment is required to justify its further use.
    Matched MeSH terms: Immunotherapy/methods*; Plasma Exchange/methods
  4. A A, R N, K P, Bing CH, R R
    Mar Pollut Bull, 2018 Aug;133:655-663.
    PMID: 30041362 DOI: 10.1016/j.marpolbul.2018.06.033
    The concentrations of nine trace metals (Cr, Mn, Co, Ni, Cu, Zn, Rb, Cd, and Pb) were measured in different tissues of two pelagic and five demersal fish species collected from the Miri coast, Sarawak. The sequence of accumulation of trace metals in different tissues were: liver > gill > gonad > muscle. Zn (301.00 μg g-1) and Cd (0.10 μg g-1) was the maximum and minimum accumulated elements. According to the Hazard Index calculation, none of the elements will pose any adverse health effects to humans for both ingestion rates (normal and habitual fish consumers) proposed by USEPA, except for Pb and Cd in certain fish species. On the basis of the results, the level of elements in the edible muscle tissues of all the analyzed fish species from the Miri coast are below the maximum permissible limits of Malaysian and International seafood guideline values and safe for consumers.
    Matched MeSH terms: Risk Assessment/methods*; Ecotoxicology/methods
  5. Ali Z, Alsulaiman M, Muhammad G, Elamvazuthi I, Al-Nasheri A, Mesallam TA, et al.
    J Voice, 2017 May;31(3):386.e1-386.e8.
    PMID: 27745756 DOI: 10.1016/j.jvoice.2016.09.009
    A large population around the world has voice complications. Various approaches for subjective and objective evaluations have been suggested in the literature. The subjective approach strongly depends on the experience and area of expertise of a clinician, and human error cannot be neglected. On the other hand, the objective or automatic approach is noninvasive. Automatic developed systems can provide complementary information that may be helpful for a clinician in the early screening of a voice disorder. At the same time, automatic systems can be deployed in remote areas where a general practitioner can use them and may refer the patient to a specialist to avoid complications that may be life threatening. Many automatic systems for disorder detection have been developed by applying different types of conventional speech features such as the linear prediction coefficients, linear prediction cepstral coefficients, and Mel-frequency cepstral coefficients (MFCCs). This study aims to ascertain whether conventional speech features detect voice pathology reliably, and whether they can be correlated with voice quality. To investigate this, an automatic detection system based on MFCC was developed, and three different voice disorder databases were used in this study. The experimental results suggest that the accuracy of the MFCC-based system varies from database to database. The detection rate for the intra-database ranges from 72% to 95%, and that for the inter-database is from 47% to 82%. The results conclude that conventional speech features are not correlated with voice, and hence are not reliable in pathology detection.
    Matched MeSH terms: Diagnosis, Computer-Assisted/methods*; Speech Production Measurement/methods*
  6. Darajeh N, Idris A, Fard Masoumi HR, Nourani A, Truong P, Rezania S
    Int J Phytoremediation, 2017 May 04;19(5):413-424.
    PMID: 27748626 DOI: 10.1080/15226514.2016.1244159
    Artificial neural networks (ANNs) have been widely used to solve the problems because of their reliable, robust, and salient characteristics in capturing the nonlinear relationships between variables in complex systems. In this study, ANN was applied for modeling of Chemical Oxygen Demand (COD) and biodegradable organic matter (BOD) removal from palm oil mill secondary effluent (POMSE) by vetiver system. The independent variable, including POMSE concentration, vetiver slips density, and removal time, has been considered as input parameters to optimize the network, while the removal percentage of COD and BOD were selected as output. To determine the number of hidden layer nodes, the root mean squared error of testing set was minimized, and the topologies of the algorithms were compared by coefficient of determination and absolute average deviation. The comparison indicated that the quick propagation (QP) algorithm had minimum root mean squared error and absolute average deviation, and maximum coefficient of determination. The importance values of the variables was included vetiver slips density with 42.41%, time with 29.8%, and the POMSE concentration with 27.79%, which showed none of them, is negligible. Results show that the ANN has great potential ability in prediction of COD and BOD removal from POMSE with residual standard error (RSE) of less than 0.45%.
    Matched MeSH terms: Waste Disposal, Fluid/methods*; Environmental Restoration and Remediation/methods*
  7. Radzuan MN, Banat IM, Winterburn J
    Bioresour Technol, 2017 Feb;225:99-105.
    PMID: 27888734 DOI: 10.1016/j.biortech.2016.11.052
    In this research we assess the feasibility of using palm oil agricultural refinery waste as a carbon source for the production of rhamnolipid biosurfactant through fermentation. The production and characterization of rhamnolipid produced by Pseudomonas aeruginosa PAO1 grown on palm fatty acid distillate (PFAD) under batch fermentation were investigated. Results show that P. aeruginosa PAO1 can grow and produce 0.43gL(-1) of rhamnolipid using PFAD as the sole carbon source. Identification of the biosurfactant product using mass spectrometry confirmed the presence of monorhamnolipid and dirhamnolipid. The rhamnolipid produced from PFAD were able to reduce surface tension to 29mNm(-1) with a critical micelle concentration (CMC) 420mgL(-1) and emulsify kerosene and sunflower oil, with an emulsion index up to 30%. Results demonstrate that PFAD could be used as a low-cost substrate for rhamnolipid production, utilizing and transforming it into a value added biosurfactant product.
    Matched MeSH terms: Biotechnology/methods*; Mass Spectrometry/methods
  8. Raghavendra U, Rajendra Acharya U, Gudigar A, Hong Tan J, Fujita H, Hagiwara Y, et al.
    Ultrasonics, 2017 05;77:110-120.
    PMID: 28219805 DOI: 10.1016/j.ultras.2017.02.003
    Thyroid is a small gland situated at the anterior side of the neck and one of the largest glands of the endocrine system. The abrupt cell growth or malignancy in the thyroid gland may cause thyroid cancer. Ultrasound images distinctly represent benign and malignant lesions, but accuracy may be poor due to subjective interpretation. Computer Aided Diagnosis (CAD) can minimize the errors created due to subjective interpretation and assists to make fast accurate diagnosis. In this work, fusion of Spatial Gray Level Dependence Features (SGLDF) and fractal textures are used to decipher the intrinsic structure of benign and malignant thyroid lesions. These features are subjected to graph based Marginal Fisher Analysis (MFA) to reduce the number of features. The reduced features are subjected to various ranking methods and classifiers. We have achieved an average accuracy, sensitivity and specificity of 97.52%, 90.32% and 98.57% respectively using Support Vector Machine (SVM) classifier. The achieved maximum Area Under Curve (AUC) is 0.9445. Finally, Thyroid Clinical Risk Index (TCRI) a single number is developed using two MFA features to discriminate the two classes. This prototype system is ready to be tested with huge diverse database.
    Matched MeSH terms: Image Interpretation, Computer-Assisted/methods*; Ultrasonography/methods*
  9. Ng KT, Chook JB, Oong XY, Chan YF, Chan KG, Hanafi NS, et al.
    Sci Rep, 2016 10 10;6:34855.
    PMID: 27721388 DOI: 10.1038/srep34855
    Human rhinovirus (HRV) is the major aetiology of respiratory tract infections. HRV viral load assays are available but limitations that affect accurate quantification exist. We developed a one-step Taqman assay using oligonucleotides designed based on a comprehensive list of global HRV sequences. The new oligonucleotides targeting the 5'-UTR region showed high PCR efficiency (E = 99.6%, R2 = 0.996), with quantifiable viral load as low as 2 viral copies/μl. Assay evaluation using an External Quality Assessment (EQA) panel yielded a detection rate of 90%. When tested on 315 human enterovirus-positive specimens comprising at least 84 genetically distinct HRV types/serotypes (determined by the VP4/VP2 gene phylogenetic analysis), the assay detected all HRV species and types, as well as other non-polio enteroviruses. A commercial quantification kit, which failed to detect any of the EQA specimens, produced a detection rate of 13.3% (42/315) among the clinical specimens. Using the improved assay, we showed that HRV sheds in the upper respiratory tract for more than a week following acute infection. We also showed that HRV-C had a significantly higher viral load at 2-7 days after the onset of symptoms (p = 0.001). The availability of such assay is important to facilitate disease management, antiviral development, and infection control.
    Matched MeSH terms: Reverse Transcriptase Polymerase Chain Reaction/methods; Real-Time Polymerase Chain Reaction/methods*
  10. Fahmy O, Schubert T, Khairul-Asri MG, Stenzl A, Gakis G
    Int J Urol, 2017 04;24(4):320-323.
    PMID: 28208217 DOI: 10.1111/iju.13307
    The surgical treatment of a long proximal ureteral stricture is a challenging situation for reconstructive surgeons. Despite the underlying morbidities, ileal interposition and autotransplantation are the options available to treat complex cases of long segment ureteral stricture. Buccal mucosa has shown excellent results in urethroplasty. However, its use in ureteral reconstruction is infrequent. We report on a 64-year-old female patient with multiple comorbidities and prior abdominal surgeries for Crohn's disease who underwent a successful total substitution of a long segment of the proximal ureter using buccal mucosa. Regular postoperative isotope scans showed improvement in renal function. Based on the pleasant outcome of this case and review of the literature, buccal mucosa might be a viable option with low morbidity in selected cases.
    Matched MeSH terms: Urologic Surgical Procedures/methods*; Reconstructive Surgical Procedures/methods*
  11. Watts G
    Lancet, 2016 Sep 24;388(10051):1274.
    PMID: 27673462 DOI: 10.1016/S0140-6736(16)31669-5
    Matched MeSH terms: Anesthesia, General/methods; Anesthesiology/methods
  12. Krishna Moorthy PS, Sivalingam S, Dillon J, Kong PK, Yakub MA
    Interact Cardiovasc Thorac Surg, 2019 02 01;28(2):191-198.
    PMID: 30085022 DOI: 10.1093/icvts/ivy234
    OBJECTIVES: Contemporary experience in mitral valve (MV) repair for children with rheumatic heart disease (RHD) is limited, despite the potential advantages of repair over replacement. We reviewed our long-term outcomes of rheumatic MV repair and compared them with the outcomes of MV replacement in children with RHD.

    METHODS: This study is a review of 419 children (≤18 years) with RHD who underwent primary isolated MV surgery between 1992 and 2015, which comprised MV repair (336 patients; 80.2%) and MV replacement (83 patients; 19.8%). The replacement group included mechanical MV replacements (MMVRs) (n = 69 patients; 16.5%) and bioprosthetic MV replacements (n = 14 patients; 3.3%). The mean age with standard deviation at the time of operation was 12.5 ± 3.5 (2-18) years. Mitral regurgitation (MR) was predominant in 390 (93.1%) patients, and 341 (81.4%) patients showed ≥3+ MR. The modified Carpentier reconstructive techniques were used for MV repair.

    RESULTS: Overall early mortality was 1.7% (7 patients). The mean follow-up was 5.6 years (range 0-22.3 years; 94.7% complete). Survival of patients who underwent repair was 93.9% both at 10 and 20 years, which was superior than that of replacement (P 

    Matched MeSH terms: Heart Valve Prosthesis Implantation/methods*; Mitral Valve Annuloplasty/methods*
  13. Shanmugapriya, Huda HA, Vijayarathna S, Oon CE, Chen Y, Kanwar JR, et al.
    Adv Exp Med Biol, 2018 9 28;1087:95-105.
    PMID: 30259360 DOI: 10.1007/978-981-13-1426-1_8
    Circular RNAs characterize a class of widespread and diverse endogenous RNAs which are non-coding RNAs that are made by back-splicing events and have covalently closed loops with no polyadenylated tails. Various indications specify that circular RNAs (circRNAs) are plentiful in the human transcriptome. However, their participation in biological processes remains mostly undescribed. To date thousands of circRNAs have been revealed in organisms ranging from Drosophila melanogaster to Homo sapiens. Functional studies specify that these transcripts control expression of protein-coding linear transcripts and thus encompass a key component of gene expression regulation. This chapter provide a comprehensive overview on functional validation of circRNAs. Furthermore, we discuss the recent modern methodologies for the functional validation of circRNAs such as RNA interference (RNAi) gene silencing assay, luciferase reporter assays, circRNA gain-of-function investigation via overexpression of circular transcript assay, RT-q-PCR quantification, and other latest applicable assays. The methods described in this chapter are demonstrated on the cellular model.
    Matched MeSH terms: In Situ Hybridization/methods; Reverse Transcriptase Polymerase Chain Reaction/methods
  14. Idros N, Chu D
    ACS Sens, 2018 09 28;3(9):1756-1764.
    PMID: 30193067 DOI: 10.1021/acssensors.8b00490
    Heavy metals are highly toxic at trace levels and their pollution has shown great threat to the environment and public health worldwide where current detection methods require expensive instrumentation and laborious operation, which can only be accomplished in centralized laboratories. Herein, we report a low-cost, paper-based microfluidic analytical device (μPAD) for facile, portable, and disposable monitoring of mercury, lead, chromium, nickel, copper, and iron ions. Triple indicators or ligands that contain ions or molecules are preloaded on the μPADs and upon addition of a metal ion, the colorimetric indicators will elicit color changes observed by the naked eyes. The color features were quantitatively analyzed in a three-dimensional space of red, green, and blue or the RGB-space using digital imaging and color calibration techniques. The sensing platform offers higher accuracy for cross references, and is capable of simultaneous detection and discrimination of different metal ions in even real water samples. It demonstrates great potential for semiquantitative and even qualitative analysis with a sensitivity below the safe limit concentrations, and a controlled error range.
    Matched MeSH terms: Colorimetry/methods*; Microfluidic Analytical Techniques/methods
  15. Mendes K, Harmanjeet H, Sedeeq M, Modi A, Wanandy T, Zaidi STR, et al.
    Perit Dial Int, 2018 07 10;38(6):430-440.
    PMID: 29991562 DOI: 10.3747/pdi.2017.00274
    BACKGROUND: Infections caused by ceftazidime-resistant Pseudomonas and extended-spectrum beta-lactamase (ESBL)-producing gram-negative bacteria are increasing worldwide. Meropenem and piperacillin/tazobactam (PIP/TZB) are recommended for the treatment of peritoneal dialysis-associated peritonitis (PDAP) caused by ceftazidime-resistant Pseudomonas and other resistant gram-negative bacteria. Patients may also receive intraperitoneal heparin to prevent occlusion of their catheters. However, the stability of meropenem or PIP/TZB, in combination with heparin, in different types of peritoneal dialysis (PD) solutions used in clinical practice is currently unknown. Therefore, we investigated the stability of meropenem and PIP/TZB, each in combination with heparin, in different PD solutions.

    METHODS: A total of 15 PD bags (3 bags for each type of PD solution) containing meropenem and heparin and 24 PD bags (3 bags for each type of PD solution) containing PIP/TZB and heparin were prepared and stored at 4°C for 168 hours. The same bags were stored at 25°C for 3 hours followed by 10 hours at 37°C. An aliquot withdrawn before storage and at defined time points was analyzed for the concentration of meropenem, PIP, TZB, and heparin using high-performance liquid chromatography. Samples were also analysed for particle content, pH and color change, and the anticoagulant activity of heparin.

    RESULTS: Meropenem and heparin retained more than 90% of their initial concentration in 4 out of 5 types of PD solutions when stored at 4°C for 168 hours, followed by storage at 25°C for 3 hours and then at 37°C for 10 hours. Piperacillin/tazobactam and heparin were found to be stable in all 8 types of PD solutions when stored under the same conditions. Heparin retained more than 98% of its initial anticoagulant activity throughout the study period. No evidence of particle formation, color change, or pH change was observed at any time under the storage conditions employed in the study.

    CONCLUSIONS: This study provides clinically important information on the stability of meropenem and PIP/TZB, each in combination with heparin, in different PD solutions. The use of meropenem-heparin admixed in pH-neutral PD solutions for the treatment of PDAP should be avoided, given the observed suboptimal stability of meropenem.

    Matched MeSH terms: Chromatography, High Pressure Liquid/methods; Peritoneal Dialysis/methods
  16. Acharya UR, Raghavendra U, Koh JEW, Meiburger KM, Ciaccio EJ, Hagiwara Y, et al.
    Comput Methods Programs Biomed, 2018 Nov;166:91-98.
    PMID: 30415722 DOI: 10.1016/j.cmpb.2018.10.006
    BACKGROUND AND OBJECTIVE: Liver fibrosis is a type of chronic liver injury that is characterized by an excessive deposition of extracellular matrix protein. Early detection of liver fibrosis may prevent further growth toward liver cirrhosis and hepatocellular carcinoma. In the past, the only method to assess liver fibrosis was through biopsy, but this examination is invasive, expensive, prone to sampling errors, and may cause complications such as bleeding. Ultrasound-based elastography is a promising tool to measure tissue elasticity in real time; however, this technology requires an upgrade of the ultrasound system and software. In this study, a novel computer-aided diagnosis tool is proposed to automatically detect and classify the various stages of liver fibrosis based upon conventional B-mode ultrasound images.

    METHODS: The proposed method uses a 2D contourlet transform and a set of texture features that are efficiently extracted from the transformed image. Then, the combination of a kernel discriminant analysis (KDA)-based feature reduction technique and analysis of variance (ANOVA)-based feature ranking technique was used, and the images were then classified into various stages of liver fibrosis.

    RESULTS: Our 2D contourlet transform and texture feature analysis approach achieved a 91.46% accuracy using only four features input to the probabilistic neural network classifier, to classify the five stages of liver fibrosis. It also achieved a 92.16% sensitivity and 88.92% specificity for the same model. The evaluation was done on a database of 762 ultrasound images belonging to five different stages of liver fibrosis.

    CONCLUSIONS: The findings suggest that the proposed method can be useful to automatically detect and classify liver fibrosis, which would greatly assist clinicians in making an accurate diagnosis.

    Matched MeSH terms: Image Interpretation, Computer-Assisted/methods; Image Processing, Computer-Assisted/methods
  17. Nguyen TDP, Tran TNT, Le TVA, Nguyen Phan TX, Show PL, Chia SR
    J Biosci Bioeng, 2019 Apr;127(4):492-498.
    PMID: 30416001 DOI: 10.1016/j.jbiosc.2018.09.004
    Nowadays, the pretreatment of wastewater prior to discharge is very important in various industries as the wastewater without any treatment contains high organic pollution loads that would pollute the receiving waterbody and potentially cause eutrophication and oxygen depletion to aquatic life. The reuse of seafood wastewater discharge in microalgae cultivation offers beneficial purposes such as reduced processing cost for wastewater treatment, replenishing ground water basin as well as financial savings for microalgae cultivation. In this paper, the cultivation of Chlorella vulgaris with an initial concentration of 0.01 ± 0.001 g⋅L-1 using seafood sewage discharge under sunlight and fluorescent illumination was investigated in laboratory-scale without adjusting mineral nutrients and pH. The ability of nutrient removal under different lighting conditions, the metabolism of C. vulgaris and new medium as well as the occurrence of auto-flocculation of microalgae biomass were evaluated for 14 days. The results showed that different illumination sources did not influence the microalgae growth, chemical oxygen demand (COD) and biochemical oxygen demand (BOD) significantly. However, the total nitrogen (total-N) and total phosphorus (total-P) contents of microalgae were sensitive to the illumination mode. The amount of COD, BOD, total-N and total-P were decreased by 88%, 81%, 95%, and 83% under sunlight mode and 81%, 74%, 79%, and 72% under fluorescent illumination, respectively. Furthermore, microalgae were auto-flocculated at the final days of cultivation with maximum biomass concentration of 0.49 ± 0.01 g⋅L-1, and the pH value had increased to pH 9.8 ± 0.1 under sunlight illumination.
    Matched MeSH terms: Water Purification/methods*; Cell Culture Techniques/methods
  18. Jamalludin Z, Jong WL, Malik RA, Rosenfeld AB, Ung NM
    Phys Med, 2020 Jan;69:52-60.
    PMID: 31830631 DOI: 10.1016/j.ejmp.2019.11.025
    PURPOSE: Dose to the rectum during brachytherapy treatment may differ from an approved treatment plan which can be quantified with in vivo dosimetry (IVD). This study compares the planned with in vivo doses measured with MOSkin and PTW 9112 rectal probe in patients undergoing CT based HDR cervical brachytherapy with Co-60 source.

    METHODS: Dose measurement of a standard pear-shaped plan carried out in phantom to verify the MOSkin dose measurement accuracy. With MOSkin attached to the third diode, RP3 of the PTW 9112, both detectors were inserted into patients' rectum. The RP3 and MOSkin measured doses in 18 sessions as well as the maximum measured doses from PTW 9112, RPmax in 48 sessions were compared to the planned doses.

    RESULTS: Percentage dose differences ΔD (%) in phantom study for two MOSkin found to be 2.22 ± 0.07% and 2.5 ± 0.07%. IVD of 18 sessions resulted in ΔD(%) of -16.3% to 14.9% with MOSkin and ΔD(%) of -35.7% to -2.1% with RP3. In 48 sessions, RPmax recorded ΔD(%) of -37.1% to 11.0%. MOSkin_measured doses were higher in 44.4% (8/18) sessions, while RP3_measured were lower than planned doses in all sessions. RPmax_measured were lower in 87.5% of applications (42/47).

    CONCLUSIONS: The delivered doses proven to deviate from planned doses due to unavoidable shift between imaging and treatment as measured with MOSkin and PTW 9112 detectors. The integration of MOSkin on commercial PTW 9112 surface found to be feasible for rectal dose IVD during cervical HDR ICBT.

    Matched MeSH terms: Brachytherapy/methods*; Radiotherapy Planning, Computer-Assisted/methods
  19. Amri NA, Quar TK, Chong FY
    Am J Audiol, 2019 Dec 16;28(4):877-894.
    PMID: 31600460 DOI: 10.1044/2019_AJA-18-0156
    Purpose This study examined the current pediatric amplification practice with an emphasis on hearing aid verification using probe microphone measurement (PMM), among audiologists in Klang Valley, Malaysia. Frequency of practice, access to PMM system, practiced protocols, barriers, and perception toward the benefits of PMM were identified through a survey. Method A questionnaire was distributed to and filled in by the audiologists who provided pediatric amplification service in Klang Valley, Malaysia. One hundred eight (N = 108) audiologists, composed of 90.3% women and 9.7% men (age range: 23-48 years), participated in the survey. Results PMM was not a clinical routine practiced by a majority of the audiologists, despite its recognition as the best clinical practice that should be incorporated into protocols for fitting hearing aids in children. Variations in practice existed warranting further steps to improve the current practice for children with hearing impairment. The lack of access to PMM equipment was 1 major barrier for the audiologists to practice real-ear verification. Practitioners' characteristics such as time constraints, low confidence, and knowledge levels were also identified as barriers that impede the uptake of the evidence-based practice. Conclusions The implementation of PMM in clinical practice remains a challenge to the audiology profession. A knowledge-transfer approach that takes into consideration the barriers and involves effective collaboration or engagement between the knowledge providers and potential stakeholders is required to promote the clinical application of evidence-based best practice.
    Matched MeSH terms: Audiology/methods; Prosthesis Fitting/methods
  20. Ngoo KS, Honda M, Kimura Y, Yumioka T, Iwamoto H, Morizane S, et al.
    Int J Med Robot, 2019 Aug;15(4):e2018.
    PMID: 31115140 DOI: 10.1002/rcs.2018
    BACKGROUND: The aim of this study is to investigate the impact of robotic-assisted radical prostatectomy (RARP) on the health-related quality of life (HRQOL).

    METHODS: We prospectively reviewed HRQOL parameters using Short-Form Health Survey, patient self-reporting of urinary incontinence and International Index of Erectile Function, among patients who underwent RARP between 2010 and 2016.

    RESULTS: Among 249 men studied, all had significantly worse HRQOL domain scores at 1 month post operatively but 24 months after surgery, all domains reached or surpassed their baseline values. Only Bodily Pain, General Health, Role-Emotional, Mental Health domains, and Mental Health Composite were significantly improved. Improvement in urinary continence was mirrored by improvements in both Mental and Physical Component Scores.

    CONCLUSIONS: Within a 2-year post-operative period, men who underwent RARP had regained their overall quality of life. The recovery of urinary continence significantly impacted the mental, physical, emotional, and social well-being of those patients.

    Matched MeSH terms: Prostatectomy/methods*; Robotic Surgical Procedures/methods*