Displaying publications 41 - 60 of 118 in total

Abstract:
Sort:
  1. Ooi PC, Mohammad Haniff MAS, Mohd Razip Wee MF, Goh BT, Dee CF, Mohamed MA, et al.
    Sci Rep, 2019 May 01;9(1):6761.
    PMID: 31043694 DOI: 10.1038/s41598-019-43279-3
    In the interest of the trend towards miniaturization of electronic gadgets, this study demonstrates a high-density data storage device with a very simple three-stacking layer consisting of only one charge trapping layer. A simple solution-processed technique has been used to fabricate the tristable non-volatile memory. The three-stacking layer was constructed in between two metals to form a two-terminal metal-insulator-metal structure. The fabricated device showed a large multilevel memory hysteresis window with a measured ON/OFF current ratio of 107 that might be attributed to the high charge trapped in molybdenum disulphide (MoS2) flakes-graphene quantum dots (GQDs) heterostructure. Transmission electron microscopy was performed to examine the orientation of MoS2-GQD and mixture dispersion preparation method. The obtained electrical data was used further to speculate the possible transport mechanisms through the fabricated device by a curve fitting technique. Also, endurance cycle and retention tests were performed at room temperature to investigate the stability of the device.
    Matched MeSH terms: Electronics
  2. Nurjuliana M, Che Man YB, Mat Hashim D, Mohamed AK
    Meat Sci, 2011 Aug;88(4):638-44.
    PMID: 21420795 DOI: 10.1016/j.meatsci.2011.02.022
    The volatile compounds of pork, other meats and meat products were studied using an electronic nose and gas chromatography mass spectrometer with headspace analyzer (GCMS-HS) for halal verification. The zNose™ was successfully employed for identification and differentiation of pork and pork sausages from beef, mutton and chicken meats and sausages which were achieved using a visual odor pattern called VaporPrint™, derived from the frequency of the surface acoustic wave (SAW) detector of the electronic nose. GCMS-HS was employed to separate and analyze the headspace gasses from samples into peaks corresponding to individual compounds for the purpose of identification. Principal component analysis (PCA) was applied for data interpretation. Analysis by PCA was able to cluster and discriminate pork from other types of meats and sausages. It was shown that PCA could provide a good separation of the samples with 67% of the total variance accounted by PC1.
    Matched MeSH terms: Electronics
  3. Noorsal E, Sooksood K, Bihr U, Becker J, Ortmanns M
    PMID: 23366775 DOI: 10.1109/EMBC.2012.6346814
    This paper describes how to employ distributed clock gating to achieve an overall low power design of a programmable waveform generator intended for a neural stimulator. The power efficiency is enabled using global timing control combined with local amplitude distribution over a bus to the local stimulator frontends. This allows the combination of local and global clock gating for complete sub-blocks of the design. A counter and a shifter employed at the local digital stimulator reduce the design complexity for the waveform generation and thus the overall power consumptions. The average power results indicate that 63% power can be saved for the global stimulator control unit and 89-96% power can be saved for the local digital stimulator by using the proposed approach. The circuit has been implemented and successfully tested in a 0.35 µm AMS HVCMOS technology.
    Matched MeSH terms: Electronics, Medical*
  4. Nima Ghamarian, Azmah Hanim, M.A., Nahavandi, M., Zulkarnain Zainal, Lim, Hong Ngee
    MyJurnal
    In the recent years, electronic packaging provides significant research and development challenges
    across multiple disciplines such as performance, materials, reliability, thermals and interconnections.
    New technologies and techniques frequently adopted can be implemented in soldering alloys of
    semiconductor sectors in terms of optimisation. Wetting contact angle or wettability of solder alloys
    is one of the important factors which has got the attention of scholars. Hence in this study, due to the
    remarkable similarity over classical solder alloys (Pb-Sn), Bi-Ag solder was investigated. Data were
    collected through the effects of aging time variation and different weight percentages of Ag in solder
    alloys. The contact angle of the alloys with Cu plate was measured by optical microscopy. Artificial
    neural networks (ANNs) were applied on the measured datasets to develop a numerical model for further
    simulation. Results of the experiments and simulations showed that the coefficient of determination (R2
    )
    is around 0.97, which signifies that the ANN set up is appropriate for the evaluation.
    Matched MeSH terms: Electronics
  5. Nasir S, Hussein MZ, Zainal Z, Yusof NA
    Materials (Basel), 2018 Feb 13;11(2).
    PMID: 29438327 DOI: 10.3390/ma11020295
    Carbon in its single entity and various forms has been used in technology and human life for many centuries. Since prehistoric times, carbon-based materials such as graphite, charcoal and carbon black have been used as writing and drawing materials. In the past two and a half decades or so, conjugated carbon nanomaterials, especially carbon nanotubes, fullerenes, activated carbon and graphite have been used as energy materials due to their exclusive properties. Due to their outstanding chemical, mechanical, electrical and thermal properties, carbon nanostructures have recently found application in many diverse areas; including drug delivery, electronics, composite materials, sensors, field emission devices, energy storage and conversion, etc. Following the global energy outlook, it is forecasted that the world energy demand will double by 2050. This calls for a new and efficient means to double the energy supply in order to meet the challenges that forge ahead. Carbon nanomaterials are believed to be appropriate and promising (when used as energy materials) to cushion the threat. Consequently, the amazing properties of these materials and greatest potentials towards greener and environment friendly synthesis methods and industrial scale production of carbon nanostructured materials is undoubtedly necessary and can therefore be glimpsed as the focal point of many researchers in science and technology in the 21st century. This is based on the incredible future that lies ahead with these smart carbon-based materials. This review is determined to give a synopsis of new advances towards their synthesis, properties, and some applications as reported in the existing literatures.
    Matched MeSH terms: Electronics
  6. Nadia Ahmad NF, Nik Ghazali NN, Wong YH
    Biosens Bioelectron, 2021 May 30;189:113384.
    PMID: 34090154 DOI: 10.1016/j.bios.2021.113384
    The advanced stimuli-responsive approaches for on-demand drug delivery systems have received tremendous attention as they have great potential to be integrated with sensing and multi-functional electronics on a flexible and stretchable single platform (all-in-one concept) in order to develop skin-integration with close-loop sensation for personalized diagnostic and therapeutic application. The wearable patch pumps have evolved from reservoir-based to matrix patch and drug-in-adhesive (single-layer or multi-layer) type. In this review, we presented the basic requirements of an artificial pancreas, surveyed the design and technologies used in commercial patch pumps available on the market and provided general information about the latest wearable patch pump. We summarized the various advanced delivery strategies with their mechanisms that have been developed to date and representative examples. Mechanical, electrical, light, thermal, acoustic and glucose-responsive approaches on patch form have been successfully utilized in the controllable transdermal drug delivery manner. We highlighted key challenges associated with wearable transdermal delivery systems, their research direction and future development trends.
    Matched MeSH terms: Electronics
  7. NURUL FITRIYAH ROSLAN, WAN MARIAM WAN MUDA
    MyJurnal
    Battery Monitoring System (BMoS) is an electronic system that monitors rechargeable battery cells or packs with various parameters, such as battery voltage, current and State-of-Charge (SoC). This system can be used to avoid overcharging or over-discharging of batteries to increase its shelf life. However, BMoS on the market is very expensive and not suitable for low cost embedded systems. As the Arduino Uno is widely used for low cost microcontroller boards, easy programming environment, and open-source platforms for building electronic projects, therefore, this study focuses on Arduino Uno BMoS based system. This system consists of current and voltage sensors, an Arduino Uno microcontroller and a liquid crystal display (LCD). In order to develop this system, there are three objectives to be achieved. First, the relationship between input and output of the sensors must be derived mathematically. The mathematical expression obtained can be verified by connecting and disconnecting the circuit with load and monitoring the value of output sensors. Then, a complete prototype of the BMoS was developed by connecting the LCD, current and voltage sensors to the Arduino Uno microcontroller. The complete prototype was tested using an 11.1 V of Lithium-ion battery and a DC motor as a load. From the results, the current sensor shows zero value when no load is connected as no current flow. The LCD also displays 11.1V of battery voltage when fully charged. Using the developed system, the user can monitor the current, the voltage and the SoC of the battery to ensure the battery is not overcharged and overused. The development of the BMoS can help to monitor the operation and performance of the batteries in any electronic systems. At the end of this study, the complete BMoS prototype gives benefits to the user and makes work easier.
    Matched MeSH terms: Electronics
  8. N. Sulaiman, B. Y. Majlis
    ASM Science Journal, 2013;7(1):27-36.
    MyJurnal
    Measurement of low magnetic field has played an important role in many electronics applications such as navigation, military, non-destructive test, traffic detection as well as medical diagnosis and treatment. The presence of magnetic field, particularly its strength and direction, can be measured using magnetometer. There are many types of magnetometers being investigated through the years and one of the prominent types is fluxgate magnetometer. The main components of fluxgate magnetometer consisting of driving coils, sensing coils and magnetic core are developed by MEMS silicon processing technology. In this paper, an investigation on physical characteristics of the three-dimensional coil structure for a micro-scaled fluxgate magnetometer is presented. The physical characteristics such as width of the coil, distance between successive coils, and gap between the top and bottom coils which would influence the magnetic energy in magnetometer is discussed. In this work, finite-element method simulations to investigate the physical characteristics of the sensing coils were carried out, where the parameter of interest is the coils’ inductance as well as the magnetic flux density. Based on the simulation results, the varying of physical characteristics of the coils had its effects particularly in coil inductance, magnetic flux density, and magnetic energy. It could also be seen that the simulated results agreed with the theoretical aspects of magnetism in a coil. From the investigations, suitable coil dimensions were proposed.
    Matched MeSH terms: Electronics
  9. Musa RM, Hassan I, Abdullah MR, Latiff Azmi MN, Abdul Majeed APP, Abu Osman NA
    Front Public Health, 2022;10:835119.
    PMID: 36033746 DOI: 10.3389/fpubh.2022.835119
    The non-complexity of tennis, coupled with its health benefits, renders it appealing and encourages varying competitions at different levels of age, gender, and expertise. However, the rapid increase in the participation rates witnesses a surge in injury occurrences, prompting the need for in-depth analysis to facilitate immediate intervention. We employed a media content analysis technique in which tennis-associated articles published in the last 5 years were examined. A total of 207 news reports were gathered and screened for analysis. Subsequently, 71 articles were excluded from the study due to content duplications or summary updates of existing news articles, while 23 news articles were also excluded from the study due to inappropriateness. Finally, 113 news reports directly related to injury in tennis were coded and analyzed. We examined various types of injuries reported from the screened articles with respect to their status (fresh, recurrent, and recovery) across expertise levels i.e., elite, or amateur. Similarly, the incidence of injury occurrences based on the types of tournaments the players engage in was also investigated. A chi-square analysis was employed to achieve the objectives of the study. Occurrences of tennis-associated injuries are disseminated across expertise levels [ χ ( 18 ) 2 = 16.542; p = 0.555], with knee, hip, elbow, and shoulder injuries being highly prevalent in both elite and amateur players. Nevertheless, it was noted that elite players suffered a staggering 72.60% of injury-related problems, while amateur players sustained 27.40% of injuries. Moreover, the status of injury spreads based on types of tournaments [ χ ( 4 ) 2 = 3.374; p = 0.497], with higher occurrences of fresh and recurrent injuries, while low recovery rates were observed. The findings further demonstrated that injuries are sustained regardless of tournament types [ χ ( 36 ) 2 = 39.393; p = 0.321]. However, most of the injuries occurred at international tournaments (85%). Whereas, only 5.30% of the injuries occurred at national/regional tournaments while 9.70% were unidentified. It could be deduced from the findings of this investigation that elite players are more prone to injuries compared with amateur players. Furthermore, the most common tennis-related injuries affect the lower, trunk, and upper regions of the body, respectively. A large number of the reported tennis injuries are fresh and recurrent, with a few recoveries. The international tennis tournaments are highly attributed to injury occurrences as opposed to the national/regional tournaments. The application of the media-based data mining technique is non-trivial in projecting injury-related problems that could be used to facilitate the development of an injury index peculiar to the tennis sport for prompt intervention.
    Matched MeSH terms: Electronics
  10. Muhammad Zubir Yusof, Nik Ahmad Kamal Nik Mahmod, Nor Azlina A. Rahman, Ailin Razali, Niza Samsuddin, Nik Mohamed Nizan Nik Mohamed, et al.
    MyJurnal
    Occupational diseases are one of the major health problems related to workplace hazards.
    However, the epidemiological data for this problem is scarce especially among Small and
    Medium Industry (SMI) workers. These workers are vulnerable to occupational health problem
    due to lack of knowledge and implementation of health and safety in the workplace. In Malaysia,
    most of the SMI workers have limited coverage for basic occupational health services which
    may worsen their health. Thus, this article aims to provide a review on the burden of
    occupational health problems among them. The electronic and library searches were used to
    extract the information from both published and unpublished articles that were not limited to any
    year of publication until 2017. One hundred and ninety-six published articles and 198
    unpublished articles were retrieved from the database. Only 19 published articles and 25
    unpublished articles met the eligibility criteria. Prevalence data of occupational
    diseases/poisoning, including overall and body specific (musculoskeletal disorders) was
    extracted in raw data from the eligible studies. Prevalent statistics on occupational
    musculoskeletal diseases (1.3% - 97.6%), noise-induced hearing loss (29.4% - 73.3%),
    occupational skin diseases (10.5% - 84.3%), respiratory (1.9% - 92.2%) and occupational
    poisoning (14.9% - 17.7%) among the working population is different within published papers
    compared to unpublished ones. In Malaysia, there are no specific statistic that give a true picture
    of the burden of occupational diseases in the SMI. However, this review concludes that
    musculoskeletal diseases are significant occupational problems among SMI workers.
    Matched MeSH terms: Electronics
  11. Muhammad F, Tahir M, Zeb M, Kalasad MN, Mohd Said S, Sarker MR, et al.
    Sci Rep, 2020 Mar 16;10(1):4828.
    PMID: 32179797 DOI: 10.1038/s41598-020-61602-1
    This paper reports the potential application of cadmium selenide (CdSe) quantum dots (QDs) in improving the microelectronic characteristics of Schottky barrier diode (SBD) prepared from a semiconducting material poly-(9,9-dioctylfluorene) (F8). Two SBDs, Ag/F8/P3HT/ITO and Ag/F8-CdSe QDs/P3HT/ITO, are fabricated by spin coating a 10 wt% solution of F8 in chloroform and 10:1 wt% solution of F8:CdSe QDs, respectively, on a pre-deposited poly(3-hexylthiophene) (P3HT) on indium tin oxide (ITO) substrate. To study the electronic properties of the fabricated devices, current-voltage (I-V) measurements are carried out at 25 °C in dark conditions. The I-V curves of Ag/F8/P3HT/ITO and Ag/F8-CdSe QDs/P3HT/ITO SBDs demonstrate asymmetrical behavior with forward bias current rectification ratio (RR) of 7.42 ± 0.02 and 142 ± 0.02, respectively, at ± 3.5 V which confirm the formation of depletion region. Other key parameters which govern microelectronic properties of the fabricated devices such as charge carrier mobility (µ), barrier height (ϕb), series resistance (Rs) and quality factor (n) are extracted from their corresponding I-V characteristics. Norde's and Cheung functions are also applied to characterize the devices to study consistency in various parameters. Significant improvement is found in the values of Rs, n, and RR by 3, 1.7, and 19 times, respectively, for Ag/F8-CdSe QDs/P3HT/ITO SBD as compared to Ag/F8/P3HT/ITO. This enhancement is due to the incorporation of CdSe QDs having 3-dimensional quantum confinement and large surface-to-volume area. Poole-Frenkle and Richardson-Schottky conduction mechanisms are also discussed for both of the devices. Morphology, optical bandgap (1.88 ± 0.5 eV) and photoluminescence (PL) spectrum of CdSe QDs with a peak intensity at 556 nm are also reported and discussed.
    Matched MeSH terms: Electronics
  12. Muhammad Azwadi Sulaiman, Hutagalung, Sabar D., Zainal A. Ahmad
    MyJurnal
    CaCu3Ti4O12 (CCTO) has attracted a great attention for electronic devices miniaturization due to its
    very high dielectric constant properties at a wide range of frequency and nearly constant over broad temperature range. The origins of the giant dielectric constant have been speculated from electrical heterogeneous of interior elements of the CCTO ceramics. Four origins were suggested contributed to the electrical heterogeneous. In this study heat treatment were done with the electrode contact in Argon gas environment and the electrical properties over very wide frequency of CCTO ceramics were investigated. Cylindrical CCTO pellets samples were prepared by solid state reaction method and single phase of XRD pattern was obtained after sintering processes. Electrical impedance responds were measured at frequency from 100 Hz to 1 GHz for the samples for untreated and heat treated at 200ºC, 250ºC, 300ºC, 350ºC and 400ºC of CCTO. Improvement to the dielectric constant can be seen for 350ºC and 400ºC samples and dielectric loss were improved for 200ºC and 300ºC samples for overall frequency. The variations were discussed based on oxygen deficiency content and resistivity of the elements inside of CCTO structure.
    Matched MeSH terms: Electronics
  13. Mohd Pisal MH, Osman AF, Jin TS, Rahman RA, Alrashdi AA, Masa A
    Polymers (Basel), 2021 Feb 17;13(4).
    PMID: 33671304 DOI: 10.3390/polym13040600
    Carbonized natural filler can offer the production of low cost composites with an eco-friendliness value. The evolving field of electronics encourages the exploration of more functions and potential for carbonized natural filler, such as by modifying its surface chemistry. In this work, we have performed surface modification on carbonized wood fiber (CWF) prior to it being used as filler in the ethylene vinyl acetate (EVA) composite system. Zinc chloride (ZnCl2) with various contents (2 to 8 wt%) was used to surface modify the CWF and the effects of ZnCl2 composition on the surface morphology and chemistry of the CWF filler were investigated. Furthermore, the absorptive, mechanical, thermal, and electrical properties of the EVA composites containing CWF-ZnCl2 were also analyzed. SEM images indicated changes in the morphology of the CWF while FTIR analysis proved the presence of ZnCl2 functional groups in the CWF. EVA composites incorporating the CWF-ZnCl2 showed superior mechanical, thermal and electrical properties compared to the ones containing the CWF. The optimum content of ZnCl2 was found to be 6 wt%. Surface modification raised the electrical conductivity of the EVA/CWF composite through the development of conductive deposits in the porous structure of the CWF as a channel for ionic and electronic transfer between the CWF and EVA matrix.
    Matched MeSH terms: Electronics
  14. Mohd Hassan S, Sulaiman Z, Tengku Ismail TA
    Malays Fam Physician, 2021 Mar 25;16(1):18-30.
    PMID: 33948139 DOI: 10.51866/rv0997
    Objective: This article aims to review the literature published over the past five decades related to the experiences of women who have undergone induced lactation.

    Methods: A comprehensive electronic search was conducted using PubMed, the Library of Congress, Google Scholar, SAGE, and ScienceDirect. The following search keywords were used: adoptive breastfeeding, induced lactation, non-puerperal lactation, extraordinary breastfeeding, and milk kinship. The search was restricted to articles written in English and published from 1956 to 2019. All study designs were included except for practice protocols.

    Results: A total of 50 articles about induced lactation were retrieved. Of these, 17 articles identified the experiences of women who underwent induced lactation. The articles included original papers (n=7), reviews (n=5), and case reports (n=5). Four articles were specifically related to Malaysia, and the others were international. These 17 articles concerning the experiences of women who induced lactation will be reviewed based on four themes related to inducing lactation: (a) understanding women's perception of satisfaction, (b) emotional aspects, (c) enabling factors, and (d) challenges.

    Conclusion: Identifying a total of only 17 articles on induced lactation published over the last 53 years suggests that the subject is understudied. This review provides emerging knowledge regarding the experiences of women who have induced lactation in terms of satisfaction, emotions, enabling factors and challenges related to inducing lactation.

    Matched MeSH terms: Electronics
  15. Mohamad Faisal Asmadi, Hasnain Abdullah, Mas Izzaty Binti Fazin, Ahmad Rashidy Razali, Mohd Nasir Taib, Azizah Ahmad, et al.
    ESTEEM Academic Journal, 2020;16(2):21-30.
    MyJurnal
    Today, electromagnetic wave theory is commonly used in many engineering devices. However, such devices produce electromagnetic (EM) radiation, damaging people's health and the impact of other electronic device's operation. Therefore, Microwave Absorber has been widely used in anechoic chamber to measure equipment radiation and prevent unwanted radiation and electromagnetic interference. This research investigates the absorption performance of pyramidal absorbers with a slotted method design. This research used rectangular and triangular slotted on the hollow pyramidal absorber. There are six types of slotted: Design 1, Design 2, and Design 3
    which have triangular shapes, and Design 4, Design 5, and Design 6, have rectangular shapes. The pyramidal absorber is produced using CST Microwave Studio Suite. Afterward, the fabrication process is performed using cardboard and coated with Powdered Activated Carbon (PAC). Measurement had been done successfully via far-field measurement using an arch method at 1 GHz to 12 GHz. The slotted pyramidal absorber's absorptivity was taken in each frequency band and was tabulated in figure 10. The result is compared with their maximum absorption in each of the four frequency bands. Comparison based on slot design, triangular and rectangular each had its own advantages at a certain frequency. However, small rectangular slot of Design 1 shows consistent absorption performance at all frequency band.
    Matched MeSH terms: Electronics
  16. Mimala Arasaratnam, Zailina Hashim, Shamsul Bahari Shamsudin
    MyJurnal
    A cross-sectional study was conducted on 83 female electronics factory workers. The respondents comprised 50 exposed workers who use lead alloy solder and 33 unexposed workers. The objective of this study was to assess the lead exposure of these workers. Breathing zone were sampled using air sampling pumps. Dust samples were collected by wipe method. Venous blood collected and blood pressure were measured. All lead analyses were carried out with Graphite Furnace Atomic Absorption Spectrophotometer. The mean air lead for exposed workers (57 0. ± 0.93 μg/m³) was significantly higher than the unexposed workers (0.0067 ± 0.0045μg/m³) (p
    Matched MeSH terms: Electronics
  17. Mendel B, Christianto, Setiawan M, Prakoso R, Siagian SN
    Curr Cardiol Rev, 2021 Jun 03.
    PMID: 34082685 DOI: 10.2174/1573403X17666210603113430
    BACKGROUND: Junctional ectopic tachycardia (JET) is an arrhythmia originating from the AV junction, which may occur following congenital heart surgery, especially when the intervention is near the atrioventricular junction.

    OBJECTIVE: The aim of this systematic review and meta-analysis is to compare the effectiveness of amiodarone, dexmedetomidine and magnesium in preventing JET following congenital heart surgery.

    METHODS: This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement, where 11 electronic databases were searched from date of inception to August 2020. The incidence of JET was calculated with the relative risk of 95% confidence interval (CI). Quality assessment of the included studies was assessed using the Consolidated Standards of Reporting Trials (CONSORT) 2010 statement.

    RESULTS: Eleven studies met the predetermined inclusion criteria and were included in this meta-analysis. Amiodarone, dexmedetomidine and magnesium significantly reduced the incidence of postoperative JET [Amiodarone: risk ratio 0.34; I2= 0%; Z=3.66 (P=0.0002); 95% CI 0.19-0.60. Dexmedetomidine: risk ratio 0.34; I2= 0%; Z=4.77 (P<0.00001); 95% CI 0.21-0.52. Magnesium: risk ratio 0.50; I2= 24%; Z=5.08 (P<0.00001); 95% CI 0.39-0.66].

    CONCLUSION: All three drugs show promise in reducing the incidence of JET. Our systematic review found that dexmedetomidine is better in reducing the length of ICU stays as well as mortality. In addition, dexmedetomidine also has the least pronounced side effects among the three. However, it should be noted that this conclusion was derived from studies with small sample sizes. Therefore, dexmedetomidine may be considered as the drug of choice for preventing JET.

    Matched MeSH terms: Electronics
  18. May Honey Ohn
    MyJurnal
    This systematic review was aimed to evaluate the effectiveness of technology-enhanced learning (TEL) used in medical teaching for undergraduate medical students. The objectives are to (a) identify various teaching modalities which are used to enhance TEL; (b) evaluate whether TEL is more effective than traditional learning (TL) in cognitive and affective learning domain outcome. The empirical studies were searched in the following databases: Google Scholar, MEDLINE, ERIC, ProQuest, Cochrane Library and Scopus. All papers published from 2008 to 2018 were included. From eligible studies, the study design, study field, study population, intervention methods, type of assessment and learning achievement were abstracted and summarized the information. The search results were independently reviewed by two authors. From a pool of 1384 articles, 43 eligible articles were identified, enrolling 7292 undergraduate medical students examining comparative study between TEL and traditional learning. The results showed that there was a high degree of heterogeneity seen amongst the included studies in terms of TEL modalities used. The majority of intervention studies favoured online resources, while the rest used various offline multimedia electronic devices, virtual simulations and blended modes. Overall findings showed promising data that TEL is better than TL with regards to knowledge gain and skill acquisition, as well as providing higher student satisfaction. In all, the findings present blended learning in a positive and promising light in time, particularly where systematic reviews on technology-enhanced learning in the field of the undergraduate medical programme have produced mixed result.REVIEW ARTICLEA Systematic Literature Review on Technology-Enhanced Learning in Medical EducationMay Honey Ohn1*, Bareth Ravindran2, Chan Zhi Wei3, Khin Maung Ohn4, Ng Pey Luen5Borneo Journal of Medical Sciences 14 (1) January, 2020: 3 – 171 Emergency Department, Sandwell & West Birmingham NHS Trust, United Kingdom2 Surgical Department, Hospital Tuanku Ja’afar Seremban, Kuala Lumpur, Malaysia3 Orthopaedics Department, Hospital Sungai Buloh, Kuala Lumpur, Malaysia4 Department of Surgery, Faculty of Medicine and Health Sciences, Universiti Malaysia Sabah, Kota Kinabalu, Sabah, Malaysia5 Radiology Department, Hospital Queen Elizabeth II, Sabah, Malaysia* Corresponding author’s email: mayhoney.ohn@gmail.com Received: 14 July 2019 Accepted: 5 November 2019Borneo Journal of Medical SciencesBJMSKeywords: blended learning, technology-enhanced learning, medical education, hybrid learning, undergraduate medical students
    Matched MeSH terms: Electronics
  19. Mahmud I, Sultana S, Rahman A, Ramayah T, Cheng Ling T
    Waste Manag Res, 2020 Dec;38(12):1438-1449.
    PMID: 32364437 DOI: 10.1177/0734242X20914753
    Each year Bangladesh produces around 400,000 metric tonnes of e-waste. E-waste accumulation is expected to increase by 20% annually. In order to facilitate e-waste recycling, it is crucial to identify the factors. In this study, building on the stimulus-organism-response framework, we develop a research model to explore the effect of information publicity, ascription of responsibility and convenience of recycling on the recycling attitude, subjective norm, personal norm and perceived behaviour control which lead to recycling intention. Data were gathered from 127 small and medium electronics store managers. The structural equation modelling technique was used to test the paths. The result suggests a significant influence of the element of stimulus (S) on the element of organism (O). The relationship between the element of organism (O) and the element of response (R) is partial. This paper contributes to the body of work dedicated to helping us better understand the recycling behaviour from the stimulus-organism-response perspective. From the viewpoint of practice, this research sheds light on some of the challenges that the implementer might face when making strategy and policy for e-waste management in Bangladesh.
    Matched MeSH terms: Electronics
  20. Low Qin Jian, Teo Kuo Zhau, Mohd Nadzri Misni, Cheo Seng Wee
    MyJurnal
    Computed tomography pulmonary angiogram (CTPA) is widely used in the investigation of suspected pulmonary embolism. CTPA is not without adverse effects as it involves intravenous contrast injection and radiation exposure. The annual incidence of pulmonary embolism is 60 – 70 per 100,000 populations and CTPA remains the commonest imaging modality1. This study aims to audit all CTPA performed at Hospital Sultanah Nora Ismail, Batu Pahat, Johor for the entire year of 2018 to illustrate the demographic data, symptoms, risk factors, clinical scoring system applied and patients’ outcome. A retrospective study was conducted to audit all CTPA performed between 1st January to 31st December 2018 via the radiology department electronic records and patients’ records. There were a total of 60 CTPA performed in the entire year of 2018 with 16 positive and 44 negative scans. Among the 16 positive scans, 7 (44%) had a Wells score above 6, 6 (38%) had a Wells score between 2 – 6 and 3 (18%) had a Wells score less than 2. Out of the 16 positive scans, 4 (25%) were known malignancy and 1 was a known case of anti-phospholipid syndrome. All 60 patients had electrographs and arterial blood gases performed prior to CTPA. D dimer was performed in 15 cases (5%). Among the 16 positive scan patients, 4 (25%) passed away during the same admission directly or indirectly related to pulmonary embolism. This annual computed tomography audit report will assist clinicians in making better diagnostic decision when dealing with patients with suspected pulmonary embolism.
    Matched MeSH terms: Electronics