Objective: To evaluate the peripapillary RNFL thickness and optic nerve functions in fellow eye of NMO with unilateral optic neuritis.
Materials and Methods: A comparative cross-sectional study was conducted in 2 tertiary hospitals from August 2017 to May 2019. RNFL thickness and optic nerve functions were evaluated. Statistical analysis was performed using Statistical Package for Social Science version 24.
Results: A total of 26 NMO patients and 26 controls were involved in this study. The median age (IQR) of NMO patients was 32.5 (12) years old. The RNFL thickness was significantly reduced in NMO patients with non-ON eyes as compared to control group. Best corrected visual acuity between the 2 groups were comparable (0.20 vs 0.00, p=0.071). Contrast sensitivity was also reduced in NMO patients (non-ON eyes) at all 5 spatial frequencies. In NMO group, 34.6% have normal colour vision. The mean deviation (MD) of Humphrey visual field (HVF) was higher in NMO group (p<0.001). There was a moderate correlation between RNFL thickness and contrast sensitivity. Weak correlation was found between the RNFL thickness with visual acuity and mean deviation of visual field test.
Conclusion: Our study showed that the fellow eye of NMO patients with unilateral ON revealed a significant reduction in RNFL thickness and all the optic nerve functions have subtle early changes that signify a subclinical retinal damage.
MATERIALS AND METHODS: Using a stainless-steel mold, disc-shaped wax patterns with dimensions of 10 mm in diameter and 2 mm thick (in accordance with ADA Specification No. 12) were created and prepared for a total of 75 acrylic samples. Dimensions of all 75 acrylic samples were checked with a digital Vernier caliper. About 25 samples of denture base material were immersed in three different chemical disinfectants: Group I: immersed in chlorhexidine gluconate solution, group II: immersed in sodium hypochlorite solution, and group III: immersed in glutaraldehyde solution. All samples were scrubbed daily for 1 minute with the appropriate disinfectant and submerged for 10 minutes in the same disinfectant. Between disinfection cycles, samples were kept in distilled water at 37°C. Color stability was measured using a reflection spectrophotometer. Surface roughness values were measured by a profilometer at baseline following 15 days and 30 days.
RESULTS: After 15 days, the color stability was better in chlorhexidine gluconate solution group (4.88 ± 0.24) than sodium hypochlorite solution (4.74 ± 0.18) and glutaraldehyde solution group (4.46 ± 0.16). The mean surface roughness was less in glutaraldehyde solution group (2.10 ± 0.19), followed by chlorhexidine gluconate solution group (2.48 ± 0.09) and sodium hypochlorite solution group (2.64 ± 0.03). After 30 days, the color stability was significantly better in chlorhexidine gluconate solution group (4.40 ± 0.02), followed by sodium hypochlorite solution (4.06 ± 0.16) and glutaraldehyde solution group (3.87 ± 0.17). The mean surface roughness was significantly lesser in glutaraldehyde solution group (2.41 ± 0.14), followed by chlorhexidine gluconate solution group (2.94 ± 0.08) and sodium hypochlorite solution group (3.02 ± 0.13).
CONCLUSION: In conclusion, the color stability was significantly better in chlorhexidine gluconate solution group than sodium hypochlorite solution and glutaraldehyde solution group. But the surface roughness was significantly lesser in the glutaraldehyde solution group, followed by the chlorhexidine gluconate and sodium hypochlorite solution group.
CLINICAL SIGNIFICANCE: The maintenance of the prosthesis requires the use of a denture disinfectant; therefore, it is crucial to select one that is effective but would not have a negative impact on the denture base resin's inherent characteristics over time. How to cite this article: Kannaiyan K, Rakshit P, Bhat MPS, et al. Effect of Different Disinfecting Agents on Surface Roughness and Color Stability of Heat-cure Acrylic Denture Material: An In Vitro Study. J Contemp Dent Pract 2023;24(11):891-894.