Displaying publications 61 - 80 of 118 in total

Abstract:
Sort:
  1. Bin Rafiq MKS, Amin N, Alharbi HF, Luqman M, Ayob A, Alharthi YS, et al.
    Sci Rep, 2020 Jan 21;10(1):771.
    PMID: 31964954 DOI: 10.1038/s41598-020-57596-5
    Radio frequency (RF) magnetron sputtering was used to deposit tungsten disulfide (WS2) thin films on top of soda lime glass substrates. The deposition power of RF magnetron sputtering varied at 50, 100, 150, 200, and 250 W to investigate the impact on film characteristics and determine the optimized conditions for suitable application in thin-film solar cells. Morphological, structural, and opto-electronic properties of as-grown films were investigated and analyzed for different deposition powers. All the WS2 films exhibited granular morphology and consisted of a rhombohedral phase with a strong preferential orientation toward the (101) crystal plane. Polycrystalline ultra-thin WS2 films with bandgap of 2.2 eV, carrier concentration of 1.01 × 1019 cm-3, and resistivity of 0.135 Ω-cm were successfully achieved at RF deposition power of 200 W. The optimized WS2 thin film was successfully incorporated as a window layer for the first time in CdTe/WS2 solar cell. Initial investigations revealed that the newly incorporated WS2 window layer in CdTe solar cell demonstrated photovoltaic conversion efficiency of 1.2% with Voc of 379 mV, Jsc of 11.5 mA/cm2, and FF of 27.1%. This study paves the way for WS2 thin film as a potential window layer to be used in thin-film solar cells.
    Matched MeSH terms: Electronics
  2. Ying Qian Ong, Sakinah Harith, Mohd Razif Shahril, Norshazila Shahidan
    MyJurnal
    Treatment effectiveness depends on the knowledge, attitude, and practice (KAP) of osteoarthritis (OA) patients to- wards their assigned treatment. This study aimed to explore the KAP towards non-surgical intervention among OA patients. A methodological framework proposed by Arksey and O’Malley (2005) was implemented. An electronic database search of English-language academic articles was conducted using PubMed and ScienceDirect databases encompassing 1998 to 2018 period of time, resulting in a total of 26 studies. OA patients were knowledgeable about the disease and exercise management. However, they were lack of knowledge on drug therapy and complementary strategies. The attitude towards non-surgical interventions was ambivalence. Lastly, the practice section mainly fo- cused on patients’ compliance and behaviour towards different conservative managements, namely physiotherapy, medications, and complementary and alternative medicines (CAMs) which influenced by both knowledge level and attitudes. In conclusion, a higher knowledge level and positive attitude will result in good practice.
    Matched MeSH terms: Electronics
  3. Ahmad Badruddin Ghazali, Nur Imanina Abdullah Thaidi
    MyJurnal
    The purpose of this study was to integrate the available data published to date on susuk or charm needles into a com- prehensive analysis of their clinical/radiological features. An electronic search was undertaken in September 2019. Eligibility criteria included publications having enough clinical and radiological to confirm a definite diagnosis. The initial literature search resulted in 48 publications. Ten publications were excluded for duplicates, and another 17 excluded after a screening of the abstract. Besides, the screening of the abstract shows that five publications were not meeting the inclusion criteria, resulting in a total of 14 publications of susuk that were included in the systematic review. Bias analysis was conducted according to Oxford Center for Evidence-Based Medicine. The resulting total of 78 cases from the selected publications were analysed, showing a wide age range with different distribution among gender and ethnicity. Three cases reported in the literature having symptoms related to susuk. Susuk can be seen as an incidental finding during a routine radiographic assessment, and clinicians should be able to differentiate it from other radiopaque foreign bodies. The practice is not limited to South East Asian population and can be seen in wide racial profiles.
    Matched MeSH terms: Electronics
  4. Venkiteswaran A, Tandon S
    J Int Soc Prev Community Dent, 2021 04 15;11(2):115-124.
    PMID: 34036071 DOI: 10.4103/jispcd.JISPCD_320_20
    Aim: This narrative aims to outline the use of hypnosis in managing dental anxiety in during dental treatment. The PICO used to answer the objectives are (P) dental patients, (I) hypnosis, (C) conventional behaviour management techniques & (O) reduced pain/anxiety.

    Materials and Methods: An electronic search of three databases; PubMed, Scopus and EBSCOhost was conducted using the keywords "hypnosis or hypnotherapy" AND "dentistry or dental" between the year 2000 and 2020. A total of 19 studies were selected based on eligibility. Data extracted were study subject, design of study, parameters used to assess, type of hypnosis script used and the study outcome.

    Results: The studies show that hypnosis is effective in pain management and dental anxiety. It can also be used for improving compliance in patients who are wearing orthodontic appliances (Trakyali et al, 2008) and reducing salivary flow during dental treatment (Satlz et al, 2014).

    Conclusion: Hypnosis has the potential to be a useful tool in the management of children and adults.

    Matched MeSH terms: Electronics
  5. Tawfik EA, Cartwright MS, Grimm A, Boon AJ, Kerasnoudis A, Preston DC, et al.
    Muscle Nerve, 2021 05;63(5):651-656.
    PMID: 33382094 DOI: 10.1002/mus.27163
    Neuromuscular ultrasound is a rapidly evolving specialty with direct application for patient care. Competency assessment is an essential standard needed to ensure quality for practitioners, particularly for those newly acquiring skills with the technique. Our aim was to survey experts' opinions regarding physician competency assessment of neuromuscular ultrasound and to identify minimal competency of knowledge and skills. The opinions of 18 experts were obtained through the Delphi method using two consecutive electronic surveys. A high degree of consensus was achieved on items regarding framework and the conduct of neuromuscular ultrasound assessment and the knowledge and skills that a candidate needs to attain minimal competency in neuromuscular ultrasound. In this study, a group of neuromuscular ultrasound experts developed a general framework for neuromuscular ultrasound competency assessment and recommended testable areas of knowledge and skills suitable for establishing minimal competency.
    Matched MeSH terms: Electronics
  6. Nadia Ahmad NF, Nik Ghazali NN, Wong YH
    Biosens Bioelectron, 2021 May 30;189:113384.
    PMID: 34090154 DOI: 10.1016/j.bios.2021.113384
    The advanced stimuli-responsive approaches for on-demand drug delivery systems have received tremendous attention as they have great potential to be integrated with sensing and multi-functional electronics on a flexible and stretchable single platform (all-in-one concept) in order to develop skin-integration with close-loop sensation for personalized diagnostic and therapeutic application. The wearable patch pumps have evolved from reservoir-based to matrix patch and drug-in-adhesive (single-layer or multi-layer) type. In this review, we presented the basic requirements of an artificial pancreas, surveyed the design and technologies used in commercial patch pumps available on the market and provided general information about the latest wearable patch pump. We summarized the various advanced delivery strategies with their mechanisms that have been developed to date and representative examples. Mechanical, electrical, light, thermal, acoustic and glucose-responsive approaches on patch form have been successfully utilized in the controllable transdermal drug delivery manner. We highlighted key challenges associated with wearable transdermal delivery systems, their research direction and future development trends.
    Matched MeSH terms: Electronics
  7. Samsudin MFR, Ullah H, Tahir AA, Li X, Ng YH, Sufian S
    J Colloid Interface Sci, 2021 Mar 15;586:785-796.
    PMID: 33198982 DOI: 10.1016/j.jcis.2020.11.003
    Herein, we performed an encyclopedic analysis on the photoelectrocatalytic hydrogen production of BiVO4/g-C3N4 decorated with reduced graphene oxide (RGO) or graphene quantum dots (GQDs). The differences between RGO and GQDs as an electron mediator was revealed for the first time in the perspective of theoretical DFT analysis and experimental validation. It was found that the incorporation of GQDs as an electron mediator promotes better photoelectrocatalytic hydrogen performance in comparison to the RGO. The addition of GQD can significantly improve the activity by 25.2 and 75.7% in comparison to the BiVO4/RGO/g-C3N4 and binary composite samples, respectively. Correspondingly, the BiVO4/GQD/g-C3N4 attained the highest photocurrent density of 19.2 mA/cm2 with an ABPE of 0.57% without the presence of any sacrificial reagents. This enhancement is stemming from the low photocharge carrier transfer resistance which was further verified via DFT study. The DFT analysis revealed that the BiVO4/GQD/g-C3N4 sample shared their electronic cloud density through orbital hybridization while the BiVO4/RGO/g-C3N4 sample show less mutual sharing. Additionally, the charge redistribution of the GQDs-composite at the heterostructure interface articulates a more stable and stronger heterojunction than the RGO-composite. Notably, this study provides new insights on the effect of different carbonaceous materials (RGO and GQDs) which are often used as an electron mediator to enhance photocatalytic activity.
    Matched MeSH terms: Electronics
  8. Fum WKS, Wong JHD, Tan LK
    Phys Med, 2021 Apr;84:228-240.
    PMID: 33849785 DOI: 10.1016/j.ejmp.2021.03.004
    PURPOSE: This systematic review aims to understand the dose estimation approaches and their major challenges. Specifically, we focused on state-of-the-art Monte Carlo (MC) methods in fluoroscopy-guided interventional procedures.

    METHODS: All relevant studies were identified through keyword searches in electronic databases from inception until September 2020. The searched publications were reviewed, categorised and analysed based on their respective methodology.

    RESULTS: Hundred and one publications were identified which utilised existing MC-based applications/programs or customised MC simulations. Two outstanding challenges were identified that contribute to uncertainties in the virtual simulation reconstruction. The first challenge involves the use of anatomical models to represent individuals. Currently, phantom libraries best balance the needs of clinical practicality with those of specificity. However, mismatches of anatomical variations including body size and organ shape can create significant discrepancies in dose estimations. The second challenge is that the exact positioning of the patient relative to the beam is generally unknown. Most dose prediction models assume the patient is located centrally on the examination couch, which can lead to significant errors.

    CONCLUSION: The continuing rise of computing power suggests a near future where MC methods become practical for routine clinical dosimetry. Dynamic, deformable phantoms help to improve patient specificity, but at present are only limited to adjustment of gross body volume. Dynamic internal organ displacement or reshaping is likely the next logical frontier. Image-based alignment is probably the most promising solution to enable this, but it must be automated to be clinically practical.

    Matched MeSH terms: Electronics
  9. Muhammad Azwadi Sulaiman, Hutagalung, Sabar D., Zainal A. Ahmad
    MyJurnal
    CaCu3Ti4O12 (CCTO) has attracted a great attention for electronic devices miniaturization due to its
    very high dielectric constant properties at a wide range of frequency and nearly constant over broad temperature range. The origins of the giant dielectric constant have been speculated from electrical heterogeneous of interior elements of the CCTO ceramics. Four origins were suggested contributed to the electrical heterogeneous. In this study heat treatment were done with the electrode contact in Argon gas environment and the electrical properties over very wide frequency of CCTO ceramics were investigated. Cylindrical CCTO pellets samples were prepared by solid state reaction method and single phase of XRD pattern was obtained after sintering processes. Electrical impedance responds were measured at frequency from 100 Hz to 1 GHz for the samples for untreated and heat treated at 200ºC, 250ºC, 300ºC, 350ºC and 400ºC of CCTO. Improvement to the dielectric constant can be seen for 350ºC and 400ºC samples and dielectric loss were improved for 200ºC and 300ºC samples for overall frequency. The variations were discussed based on oxygen deficiency content and resistivity of the elements inside of CCTO structure.
    Matched MeSH terms: Electronics
  10. Chuan MW, Wong KL, Riyadi MA, Hamzah A, Rusli S, Alias NE, et al.
    PLoS One, 2021;16(6):e0253289.
    PMID: 34125874 DOI: 10.1371/journal.pone.0253289
    Silicene has attracted remarkable attention in the semiconductor research community due to its silicon (Si) nature. It is predicted as one of the most promising candidates for the next generation nanoelectronic devices. In this paper, an efficient non-iterative technique is employed to create the SPICE models for p-type and n-type uniformly doped silicene field-effect transistors (FETs). The current-voltage characteristics show that the proposed silicene FET models exhibit high on-to-off current ratio under ballistic transport. In order to obtain practical digital logic timing diagrams, a parasitic load capacitance, which is dependent on the interconnect length, is attached at the output terminal of the logic circuits. Furthermore, the key circuit performance metrics, including the propagation delay, average power, power-delay product and energy-delay product of the proposed silicene-based logic gates are extracted and benchmarked with published results. The effects of the interconnect length to the propagation delay and average power are also investigated. The results of this work further envisage the uniformly doped silicene as a promising candidate for future nanoelectronic applications.
    Matched MeSH terms: Electronics
  11. Nasir S, Hussein MZ, Zainal Z, Yusof NA
    Materials (Basel), 2018 Feb 13;11(2).
    PMID: 29438327 DOI: 10.3390/ma11020295
    Carbon in its single entity and various forms has been used in technology and human life for many centuries. Since prehistoric times, carbon-based materials such as graphite, charcoal and carbon black have been used as writing and drawing materials. In the past two and a half decades or so, conjugated carbon nanomaterials, especially carbon nanotubes, fullerenes, activated carbon and graphite have been used as energy materials due to their exclusive properties. Due to their outstanding chemical, mechanical, electrical and thermal properties, carbon nanostructures have recently found application in many diverse areas; including drug delivery, electronics, composite materials, sensors, field emission devices, energy storage and conversion, etc. Following the global energy outlook, it is forecasted that the world energy demand will double by 2050. This calls for a new and efficient means to double the energy supply in order to meet the challenges that forge ahead. Carbon nanomaterials are believed to be appropriate and promising (when used as energy materials) to cushion the threat. Consequently, the amazing properties of these materials and greatest potentials towards greener and environment friendly synthesis methods and industrial scale production of carbon nanostructured materials is undoubtedly necessary and can therefore be glimpsed as the focal point of many researchers in science and technology in the 21st century. This is based on the incredible future that lies ahead with these smart carbon-based materials. This review is determined to give a synopsis of new advances towards their synthesis, properties, and some applications as reported in the existing literatures.
    Matched MeSH terms: Electronics
  12. Nima Ghamarian, Azmah Hanim, M.A., Nahavandi, M., Zulkarnain Zainal, Lim, Hong Ngee
    MyJurnal
    In the recent years, electronic packaging provides significant research and development challenges
    across multiple disciplines such as performance, materials, reliability, thermals and interconnections.
    New technologies and techniques frequently adopted can be implemented in soldering alloys of
    semiconductor sectors in terms of optimisation. Wetting contact angle or wettability of solder alloys
    is one of the important factors which has got the attention of scholars. Hence in this study, due to the
    remarkable similarity over classical solder alloys (Pb-Sn), Bi-Ag solder was investigated. Data were
    collected through the effects of aging time variation and different weight percentages of Ag in solder
    alloys. The contact angle of the alloys with Cu plate was measured by optical microscopy. Artificial
    neural networks (ANNs) were applied on the measured datasets to develop a numerical model for further
    simulation. Results of the experiments and simulations showed that the coefficient of determination (R2
    )
    is around 0.97, which signifies that the ANN set up is appropriate for the evaluation.
    Matched MeSH terms: Electronics
  13. Kuziel AW, Milowska KZ, Chau PL, Boncel S, Koziol KK, Yahya N, et al.
    Adv Mater, 2020 Aug;32(34):e2000608.
    PMID: 32672882 DOI: 10.1002/adma.202000608
    The fundamental colloidal properties of pristine graphene flakes remain incompletely understood, with conflicting reports about their chemical character, hindering potential applications that could exploit the extraordinary electronic, thermal, and mechanical properties of graphene. Here, the true amphipathic nature of pristine graphene flakes is demonstrated through wet-chemistry testing, optical microscopy, electron microscopy, and density functional theory, molecular dynamics, and Monte Carlo calculations, and it is shown how this fact paves the way for the formation of ultrastable water/oil emulsions. In contrast to commonly used graphene oxide flakes, pristine graphene flakes possess well-defined hydrophobic and hydrophilic regions: the basal plane and edges, respectively, the interplay of which allows small flakes to be utilized as stabilizers with an amphipathic strength that depends on the edge-to-surface ratio. The interactions between flakes can be also controlled by varying the oil-to-water ratio. In addition, it is predicted that graphene flakes can be efficiently used as a new-generation stabilizer that is active under high pressure, high temperature, and in saline solutions, greatly enhancing the efficiency and functionality of applications based on this material.
    Matched MeSH terms: Electronics
  14. Sreeramareddy CT, Shroff SM, Gunjal S
    Subst Abuse Treat Prev Policy, 2023 Aug 29;18(1):51.
    PMID: 37644524 DOI: 10.1186/s13011-023-00558-7
    BACKGROUND: Nicotine dependence, factors associated with dependence, and self-reported side effects among people who use e-cigarettes are scarce in developing countries.

    METHODS: A sample of 302 persons who currently use e-cigarettes was recruited from discussion forums on Reddit, Facebook, and the forum 'lowyat'. The online Google form survey collected data on demographics, e-cigarette use, and the reasons, for cigarette smoking, Fagerstorm Test for Nicotine Dependence adapted for e-cigarettes (eFTND), and side effects experienced.

    RESULTS: The mean age was 25.5 years (6.5), 60.6% were males and 86% had higher education. About 47% were using e-cigarettes only, 27.8% were currently using dual products (both electronic and conventional cigarettes), and 25.2% had also smoked cigarettes in the past. 'Less harmful than cigarettes' (56.3%), 'because I enjoy it' (46.7%), and 'it has a variety of flavors (40.4%) were the common reasons for e-cigarette use. The mean eFTND score was 3.9 (SD = 2.2), with a median of four side effects (IQR 3-6), sore or dry mouth/throat (41.4%), cough 33.4%, headache (20.5%), dizziness (16.2%) were commonly reported side effects. eFTND score and side effects were higher among persons using dual products. By multiple linear regression analysis, males (β = 0.56 95% CI 0.45, 1.05, p = 0.033), dual-use (β = 0.95 95% CI 0.34, 1.56, p 

    Matched MeSH terms: Electronics
  15. He Y, Kiehbadroudinezhad M, Hosseinzadeh-Bandbafha H, Gupta VK, Peng W, Lam SS, et al.
    Environ Pollut, 2024 Feb 01;342:123081.
    PMID: 38072018 DOI: 10.1016/j.envpol.2023.123081
    E-waste, encompassing discarded materials from outdated electronic equipment, often ends up intermixed with municipal solid waste, leading to improper disposal through burial and incineration. This improper handling releases hazardous substances into water, soil, and air, posing significant risks to ecosystems and human health, ultimately entering the food chain and water supply. Formal e-waste recycling, guided by circular economy models and zero-discharge principles, offers potential solutions to this critical challenge. However, implementing a circular economy for e-waste management due to chemical and energy consumption may cause environmental impacts. Consequently, advanced sustainability assessment tools, such as Life Cycle Assessment (LCA), have been applied to investigate e-waste management strategies. While LCA is a standardized methodology, researchers have employed various routes for environmental assessment of different e-waste management methods. However, to the authors' knowledge, there lacks a comprehensive study focusing on LCA studies to discern the opportunities and limitations of this method in formal e-waste management strategies. Hence, this review aims to survey the existing literature on the LCA of e-waste management under a circular economy, shedding light on the current state of research, identifying research gaps, and proposing future research directions. It first explains various methods of managing e-waste in the circular economy. This review then evaluates and scrutinizes the LCA approach in implementing the circular bioeconomy for e-waste management. Finally, it proposes frameworks and procedures to enhance the applicability of the LCA method to future e-waste management research. The literature on the LCA of e-waste management reveals a wide variation in implementing LCA in formal e-waste management, resulting in diverse results and findings in this field. This paper underscores that LCA can pinpoint the environmental hotspots for various pathways of formal e-waste recycling, particularly focusing on metals. It can help address these concerns and achieve greater sustainability in e-waste recycling, especially in pyrometallurgical and hydrometallurgical pathways. The recovery of high-value metals is more environmentally justified compared to other metals. However, biometallurgical pathways remain limited in terms of environmental studies. Despite the potential for recycling e-waste into plastic or glass, there is a dearth of robust background in LCA studies within this sector. This review concludes that LCA can offer valuable insights for decision-making and policy processes on e-waste management, promoting environmentally sound e-waste recycling practices. However, the accuracy of LCA results in e-waste recycling, owing to data requirements, subjectivity, impact category weighting, and other factors, remains debatable, emphasizing the need for more uncertainty analysis in this field.
    Matched MeSH terms: Electronics
  16. Hannan MA, Hussein HA, Mutashar S, Samad SA, Hussain A
    Sensors (Basel), 2014;14(12):23843-70.
    PMID: 25615728 DOI: 10.3390/s141223843
    With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of implanted device research in the future. This review will hopefully lead to increasing efforts towards the development of low powered, highly efficient, high data rate and reliable automatic frequency controllers for implanted devices.
    Matched MeSH terms: Electronics, Medical/methods*
  17. Zaman MR, Islam MT, Misran N, Yatim B
    ScientificWorldJournal, 2014;2014:831435.
    PMID: 24977230 DOI: 10.1155/2014/831435
    A radio frequency (RF) resonator using glass-reinforced epoxy material for C and X band is proposed in this paper. Microstrip line technology for RF over glass-reinforced epoxy material is analyzed. Coupling mechanism over RF material and parasitic coupling performance is explained utilizing even and odd mode impedance with relevant equivalent circuit. Babinet's principle is deployed to explicate the circular slot ground plane of the proposed resonator. The resonator is designed over four materials from different backgrounds which are glass-reinforced epoxy, polyester, gallium arsenide (GaAs), and rogers RO 4350B. Parametric studies and optimization algorithm are applied over the geometry of the microstrip resonator to achieve dual band response for C and X band. Resonator behaviors for different materials are concluded and compared for the same structure. The final design is fabricated over glass-reinforced epoxy material. The fabricated resonator shows a maximum directivity of 5.65 dBi and 6.62 dBi at 5.84 GHz and 8.16 GHz, respectively. The lowest resonance response is less than -20 dB for C band and -34 dB for X band. The resonator is prototyped using LPKF (S63) drilling machine to study the material behavior.
    Matched MeSH terms: Electronics/instrumentation*
  18. Abdullah WR, Zakaria A, Ghazali MS
    Int J Mol Sci, 2012;13(4):5278-89.
    PMID: 22606043 DOI: 10.3390/ijms13045278
    High demands on low-voltage electronics have increased the need for zinc oxide (ZnO) varistors with fast response, highly non-linear current-voltage characteristics and energy absorption capabilities at low breakdown voltage. However, trade-off between breakdown voltage and grain size poses a critical bottle-neck in the production of low-voltage varistors. The present study highlights the synthesis mechanism for obtaining praseodymium oxide (Pr(6)O(11)) based ZnO varistor ceramics having breakdown voltages of 2.8 to 13.3 V/mm through employment of direct modified citrate gel coating technique. Precursor powder and its ceramics were examined by means of TG/DTG, FTIR, XRD and FESEM analyses. The electrical properties as a function of Pr(6)O(11) addition were analyzed on the basis of I-V characteristic measurement. The breakdown voltage could be adjusted from 0.01 to 0.06 V per grain boundary by controlling the amount of Pr(6)O(11) from 0.2 to 0.8 mol%, without alteration of the grain size. The non-linearity coefficient, α, varied from 3.0 to 3.5 and the barrier height ranged from 0.56 to 0.64 eV. Breakdown voltage and α lowering with increasing Pr(6)O(11) content were associated to reduction in the barrier height caused by variation in O vacancies at grain boundary.
    Matched MeSH terms: Electronics, Medical/instrumentation*
  19. Haidar AM, Mohamed A, Al-Dabbagh M, Hussain A, Masoum M
    Int J Neural Syst, 2009 Dec;19(6):473-9.
    PMID: 20039470
    Load shedding is some of the essential requirement for maintaining security of modern power systems, particularly in competitive energy markets. This paper proposes an intelligent scheme for fast and accurate load shedding using neural networks for predicting the possible loss of load at the early stage and neuro-fuzzy for determining the amount of load shed in order to avoid a cascading outage. A large scale electrical power system has been considered to validate the performance of the proposed technique in determining the amount of load shed. The proposed techniques can provide tools for improving the reliability and continuity of power supply. This was confirmed by the results obtained in this research of which sample results are given in this paper.
    Matched MeSH terms: Electronics/methods
  20. Senthilpari C, Diwakar K, Singh AK
    Recent Pat Nanotechnol, 2009;3(1):61-72.
    PMID: 19149756
    The paper discuss the design of 1-bit full adder circuit using Shannon theorem. This proposed full adder circuit is used as one of the circuit component for implementation of Non- Restoring and Restoring divider circuits. The proposed adder and divider schematics are designed by using DSCH2 CAD tool and their layouts are generated by Microwind 3 VLSI CAD tool. The divider circuits are designed by using standard CMOS 0.35 microm feature size and corresponding power supply 3.5 V. The parameters analyses are carried out by BSIM 4 analysis. We have compared the simulated results of the Shannon based divider circuit with CPL and CMOS adder cell based divider circuits. We have further compared the results with published results and observed that the proposed adder cell based divider circuit dissipates lower power, gives faster response, lower latency, low EPI and high throughput.
    Matched MeSH terms: Electronics/instrumentation*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links