METHODS: Membrane films were prepared from water-soluble O-C solution blended with various concentrations of glycerol to modify the physical properties of the films. In vitro and in vivo biocompatibility evaluations were performed using primary human skin fibroblast cultures and subcutaneous implantation in a rat model, respectively.
RESULTS: Addition of glycerol significantly influenced the barrier and mechanical properties of the films. Water absorption capacity was in the range of 80%-160%, whereas water vapor transmission rate varied from 1,180 to 1,618 g/m2 per day. Both properties increased with increasing glycerol concentration. Tensile strength decreased while elongation at break increased with the addition of glycerol. O-C films were found to be noncytotoxic to human fibroblast cultures and histological examination proved that films are biocompatible.
CONCLUSION: These results indicate that the membrane film from O-C has potential application as a wound-dressing material.
METHODS: Polyvinylpyrrolidone-capped AgNPs were synthesized by ultrasound-assisted chemical reduction. Characterization of the AgNPs involved UV-visible spectroscopy, Fourier transform infrared spectroscopy, X-ray diffraction, transmission electron microscopy, and energy dispersive X-ray spectroscopy. Citrobacter sp. A1 and Enterococcus sp. C1 were exposed to varying concentrations of AgNPs, and cell viability was determined. Scanning electron microscopy was performed to evaluate the morphological alteration of both species upon exposure to AgNPs at 1000 mg/L.
RESULTS: The synthesized AgNPs were spherical in shape, with an average particle size of 15 nm. The AgNPs had different but prominent effects on either Citrobacter sp. A1 or Enterococcus sp. C1. At an AgNP concentration of 1000 mg/L, Citrobacter sp. A1 retained viability for 6 hours, while Enterococcus sp. C1 retained viability only for 3 hours. Citrobacter sp. A1 appeared to be more resistant to AgNPs than Enterococcus sp. C1. The cell wall of both strains was found to be morphologically altered at that concentration.
CONCLUSION: Minute and spherical AgNPs significantly affected the viability of the two bacterial strains selected from the environment. Enterococcus sp. C1 was more vulnerable to AgNPs, probably due to its cell wall architecture and the absence of silver resistance-related genes.
METHODS: We carried out a prospective analysis based on the DFI samples collected from 2016 till 2018. Specimens were cultured with optimal techniques in addition to antibiotic susceptibility based on recommendations from The Clinical and Laboratory Standards Institute (CLSI). A total of 1040 pathogens were isolated with an average of 1.9 pathogens per lesion in 550 patients who were identified with having DFIs during this interval.
RESULTS: A higher percentage of Gram-negative pathogens (54%) were identified as compared with Gram-positive pathogens (33%) or anaerobes (12%). A total of 85% of the patients were found to have polymicrobial infections. Pseudomonas aeruginosa (19%), Staphylococcus aureus (11%) and Bacteroides species (8%) appeared to be the predominant organisms isolated. In the management of Gram-positive bacteria, the most efficacious treatment was seen with the use of Vancomycin, while Imipenem and Amikacin proved to be effective in the treatment of Gram-negative bacteria.
CONCLUSION: DFI's are common among Malaysians with diabetes, with a majority of cases displaying polymicrobial aetiology with multi-drug resistant isolates. The data obtained from this study will be valuable in aiding future empirical treatment guidelines in the treatment of DFIs. This study investigated the microbiology of DFIs and their resistance to antibiotics in patients with DFIs that were managed at a Tertiary Care Centre in Malaysia.
Material and Methods: We conducted a retrospective study of children with angular deformity of the knee treated by the guided growth technique from January 2010 to December 2015 in a tertiary centre. The guided growth technique was done using either the flexible titanium plate (8-plate) or the 2-hole reconstruction plate. Correction of deformity was assessed on radiographs by evaluating the mechanical axis deviation and tibiofemoral angle. The implants were removed once deformity correction was achieved.
Results: A total of 17 patients (27 knees) were evaluated. Twenty-two knees (81.5%) achieved complete correction of the deformity. The median age was 4.0 (interquartile range 3.0-6.0) years and the median Body Mass Index (BMI) was 26.0 (25.0-28.0). There were 7 unilateral and 10 bilateral deformities with different pathologies (14 tibia vara, 3 genu valgus). The median rate of correction was 0.71° per month. One patient (1 knee) had screw pull-out and two patients (4 knees) had broken screws in the proximal tibia. Three patients (5 knees) failed to achieve complete correction and were subsequently treated with corrective osteotomies. Out of five patients (8 knees) who were followed-up for at least 12 months after removal of hardware, two had rebound deformities. No permanent growth retardation occurred in our patients.
Conclusion: Our outcome for guided growth to correct knee angular deformity was similar to other studies. Guided growth is safe to perform in children below 12 years old and has good outcome in idiopathic genu valgus and Langeskiold II for tibia vara. Patients should be observed for recurrence until skeletal maturity following implant removal.