Displaying publications 161 - 180 of 403 in total

Abstract:
Sort:
  1. Mehrabi MH, Suhatril M, Ibrahim Z, Ghodsi SS, Khatibi H
    PLoS One, 2017;12(6):e0176480.
    PMID: 28570657 DOI: 10.1371/journal.pone.0176480
    Conventional seismic rehabilitation methods may not be suitable for some buildings owing to their high cost and time-consuming foundation work. In recent years, viscoelastic dampers (VEDs) have been widely used in many mid- and high-rise buildings. This study introduces a viscoelastic passive control system called rotary rubber braced damper (RRBD). The RRBD is an economical, lightweight, and easy-to-assemble device. A finite element model considering nonlinearity, large deformation, and material damage is developed to conduct a parametric study on different damper sizes under pushover cyclic loading. The fundamental characteristics of this VED system are clarified by analyzing building structures under cyclic loading. The result show excellent energy absorption and stable hysteresis loops in all specimens. Additionally, by using a sinusoidal shaking table test, the effectiveness of the RRBD to manage the response displacement and acceleration of steel frames is considered. The RRBD functioned at early stages of lateral displacement, indicating that the system is effective for all levels of vibration. Moreover, the proposed damper shows significantly better performance in terms of the column compression force resulting from the brace action compared to chevron bracing (CB).
    Matched MeSH terms: Equipment Design*
  2. Ang SH, Thevarajah TM, Woi PM, Alias YB, Khor SM
    J Chromatogr B Analyt Technol Biomed Life Sci, 2016 Mar 15;1015-1016:157-165.
    PMID: 26927875 DOI: 10.1016/j.jchromb.2016.01.059
    An immunosensor that operates based on the principles of lateral flow was developed for direct detection of hemoglobin A1c (HbA1c) in whole blood. We utilized colloidal gold-functionalized antibodies to transduce the specific signal generated when sandwich immuno-complexes were formed on the strip in the presence of HbA1c. The number and intensity of the test lines on the strips indicate normal, under control, and elevated levels of HbA1c. In addition, a linear relationship between HbA1c levels and immunosensor signal intensity was confirmed, with a dynamic range of 4-14% (20-130 mmol mol(-1)) HbA1c. Using this linear relationship, we determined the HbA1c levels in blood as a function of the signal intensity on the strips. Measurements were validated using the Bio-Rad Variant II HPLC and DCA Vantage tests. Moreover, the immunosensor was verified to be highly selective for detection of HbA1c against HbA0, glycated species of HbA0, and HbA2. The limit of detection was found to be 42.5 μg mL(-1) (1.35 mmol mol(-1)) HbA1c, which is reasonably sensitive compared to the values reported for microarray immunoassays. The shelf life of the immunosensor was estimated to be 1.4 months when stored at ambient temperature, indicating that the immunoassay is stable. Thus, the lateral flow immunosensor developed here was shown to be capable of performing selective, accurate, rapid, and stable detection of HbA1c in human blood samples.
    Matched MeSH terms: Equipment Design
  3. Akbari E, Buntat Z, Shahraki E, Parvaz R, Kiani MJ
    J Biomater Appl, 2016 Jan;30(6):677-85.
    PMID: 26024896 DOI: 10.1177/0885328215585682
    Graphene is another allotrope of carbon with two-dimensional monolayer honeycomb. Owing to its special characteristics including electrical, physical and optical properties, graphene is known as a more suitable candidate compared to other materials to be used in the sensor application. It is possible, moreover, to use biosensor by using electrolyte-gated field effect transistor based on graphene (GFET) to identify the alterations in charged lipid membrane properties. The current article aims to show how thickness and charges of a membrane electric can result in a monolayer graphene-based GFET while the emphasis is on the conductance variation. It is proposed that the thickness and electric charge of the lipid bilayer (LLP and QLP) are functions of carrier density, and to find the equation relating these suitable control parameters are introduced. Artificial neural network algorithm as well as support vector regression has also been incorporated to obtain other models for conductance characteristic. The results comparison between analytical models, artificial neural network and support vector regression with the experimental data extracted from previous work show an acceptable agreement.
    Matched MeSH terms: Equipment Design
  4. Islam MT, Samsuzzaman M, Islam MT, Kibria S
    Sensors (Basel), 2018 Dec 14;18(12).
    PMID: 30558191 DOI: 10.3390/s18124427
    An experimental system for early screening of a breast tumor is presented in this article. The proposed microwave imaging (MI) system consists of a moveable array of nine improved negative-index metamaterial (MTM)-loaded ultrawideband (UWB) antenna sensor with incorporation of a corresponding SRR (split-ring resonator) and CLS (capacitively loaded strip) structure, in a circular array, the stepper motor-based array-mounting stand, the adjustable phantom hanging platform, an RF switching system to control the receivers, and a personal computer-based signal processing and image reconstruction unit using MATLAB. The improved antenna comprises of four-unit cells along one axis, where an individual unit cell integrates a balancing SRR and CLS pair, which makes the antenna radiation omnidirectional over the operating frequencies. The electrical dimensions of this proposed antenna are 0.28λ × 0.20λ × 0.016λ, measured at the lowest operating frequency of 2.97 GHz as the operating bandwidth of this is in between 2.97⁻15 GHz (134.82% bandwidth), with stable directional radiation pattern. SP8T 8 port switch is used to enable the eight receiver antennas to sequentially send a 3⁻8.0 GHz microwave signal to capture the backscattered signal by MATLAB software. A low-cost realistic homogeneous breast phantom with tumor material is developed and measured to test the capability of the imaging system to detect the breast tumors. A post-processing delay-multiply-and-sum (DMAS) algorithm is used to process the recorded backscatter signal to get an image of the breast phantom, and to accurately identify the existence and located area of multiple breast tumor tissues.
    Matched MeSH terms: Equipment Design
  5. Williams DP, Jarczok MN, Ellis RJ, Hillecke TK, Thayer JF, Koenig J
    Clin Physiol Funct Imaging, 2017 Nov;37(6):776-781.
    PMID: 26815165 DOI: 10.1111/cpf.12321
    Recently, research has validated the use of Polar® heart rate monitors as a tool to index heart rate variability (HRV). In the current investigation, we sought to evaluate the test-retest reliability of both time and frequency domain measures of HRV using the Polar® RS800CX™ . Continuous HRV data were collected as 60 nominally healthy adults underwent a resting and orthostatic stress test. We evaluated reproducibility by means of the interclass correlation coefficient for absolute agreement and consistency, and the standard error of measurement. We found moderate reliable 2-week test-retest reliability of HRV using the Polar® RS800CX™ , results that are in line with previous studies that have validated the stability of HRV using other methods of measurement (e.g. electrocardiogram). Additionally, when examining different methods of spectral density estimation, we found that using the auto-regressive transformation method provides the most stable indices of HRV. Taken together, our results suggest that the Polar® RS800CX™ is not only a valid method to record HRV, but also a reliable one, particularly when using the auto-regressive transformation method.
    Matched MeSH terms: Equipment Design
  6. Chong PL, Singh AK, Kok SL
    PLoS One, 2019;14(12):e0227153.
    PMID: 31881078 DOI: 10.1371/journal.pone.0227153
    It is well proven that electrical energy can be harvested from the living plants which can be used as a potential renewable energy source for powering wireless devices in remote areas where replacing or recharging the battery is a difficult task. Therefore, harvesting electrical energy from living plants in remote areas such as in farms or forest areas can be an ideal source of energy as these areas are rich with living plants. The present paper proposes a design of a power management circuit that can harness, store and manage the electrical energy which is harvested from the leaves of Aloe Barbadensis Miller (Aloe Vera) plants to trigger a transmitter load to power a remote sensor. The power management circuit consists of two sections namely; an energy storage system that acts as an energy storage reservoir to store the energy harvested from the plants as well as a voltage regulation system which is used to boost and manage the energy in accordance to a load operation. The experimental results show that the electrical energy harvested from the Aloe Vera under a specific setup condition can produce an output of 3.49 V and 1.1 mA. The harvested energy is being channeled to the power management circuit which can boost the voltage to 10.9 V under no load condition. The harvested energy from the plants boosted by the power management circuit can turn ON the transmitter automatically to activate a temperature and humidity sensor to measure the environmental stimuli periodically with a ton of 1.22 seconds and toff of 0.46 seconds. This proves that this new source of energy combined with a power management circuit can be employed for powering the wireless sensor network for application in the Internet of Things (IoT).
    Matched MeSH terms: Equipment Design
  7. Tu Y, Ahmad N, Briscoe J, Zhang DW, Krause S
    Anal Chem, 2018 07 17;90(14):8708-8715.
    PMID: 29932632 DOI: 10.1021/acs.analchem.8b02244
    Light-addressable potentiometric sensors (LAPS) are of great interest in bioimaging applications such as the monitoring of concentrations in microfluidic channels or the investigation of metabolic and signaling events in living cells. By measuring the photocurrents at electrolyte-insulator-semiconductor (EIS) and electrolyte-semiconductor structures, LAPS can produce spatiotemporal images of chemical or biological analytes, electrical potentials and impedance. However, its commercial applications are often restricted by their limited AC photocurrents and resolution of LAPS images. Herein, for the first time, the use of 1D semiconducting oxides in the form of ZnO nanorods for LAPS imaging is explored to solve this issue. A significantly increased AC photocurrent with enhanced image resolution has been achieved based on ZnO nanorods, with a photocurrent of 45.7 ± 0.1 nA at a light intensity of 0.05 mW, a lateral resolution as low as 3.0 μm as demonstrated by images of a PMMA dot on ZnO nanorods and a pH sensitivity of 53 mV/pH. The suitability of the device for bioanalysis and bioimaging was demonstrated by monitoring the degradation of a thin poly(ester amide) film with the enzyme α-chymotrypsin using LAPS. This simple and robust route to fabricate LAPS substrates with excellent performance would provide tremendous opportunities for bioimaging.
    Matched MeSH terms: Equipment Design
  8. Naz MY, Sulaiman SA, Ariwahjoedi B, Ku Shaari KZ
    ScientificWorldJournal, 2013;2013:796081.
    PMID: 24307881 DOI: 10.1155/2013/796081
    The hot water sprays are an important part of many industrial processes, where the detailed knowledge of physical phenomena involved in jet transportation, interaction, secondary breakup, evaporation, and coalescence of droplets is important to reach more efficient processes. The objective of the work was to study the water spray jet breakup dynamics, vortex cloud formation, and droplet size distribution under varying temperature and load pressure. Using a high speed camera, the spray patterns generated by axisymmetric full cone nozzles were visualized as a function water temperature and load pressure. The image analysis confirmed that the spray cone angle and width do not vary significantly with increasing Reynolds and Weber numbers at early injection phases leading to increased macroscopic spray propagation. The formation and decay of semitorus like vortex clouds were also noticed in spray structures generated at near water boiling point temperature. For the nozzle with smallest orifice diameter (1.19 mm), these vortex clouds were very clear at 90°C heating temperature and 1 bar water load pressure. In addition, the sauter mean diameter (SMD) of the spray droplets was also measured by using Phase Doppler Anemometry (PDA) at different locations downstream of the nozzle exit. It was noticed that SMD varies slightly w.r.t. position when measured at room temperature whereas at higher temperature values, it became almost constant at distance of 55 mm downstream of the nozzle exit.
    Matched MeSH terms: Equipment Design
  9. Gopinath SC, Tang TH, Chen Y, Citartan M, Tominaga J, Lakshmipriya T
    Biosens Bioelectron, 2014 Nov 15;61:357-69.
    PMID: 24912036 DOI: 10.1016/j.bios.2014.05.024
    Influenza viruses, which are RNA viruses belonging to the family Orthomyxoviridae, cause respiratory diseases in birds and mammals. With seasonal epidemics, influenza spreads all over the world, resulting in pandemics that cause millions of deaths. Emergence of various types and subtypes of influenza, such as H1N1 and H7N9, requires effective surveillance to prevent their spread and to develop appropriate anti-influenza vaccines. Diagnostic probes such as glycans, aptamers, and antibodies now allow discrimination among the influenza strains, including new subtypes. Several sensors have been developed based on these probes, efforts made to augment influenza detection. Herein, we review the currently available sensing strategies to detect influenza viruses.
    Matched MeSH terms: Equipment Design
  10. Gopinath SC, Tang TH, Chen Y, Citartan M, Lakshmipriya T
    Biosens Bioelectron, 2014 Oct 15;60:332-42.
    PMID: 24836016 DOI: 10.1016/j.bios.2014.04.014
    The ubiquitous nature of bacteria enables them to survive in a wide variety of environments. Hence, the rise of various pathogenic species that are harmful to human health raises the need for the development of accurate sensing systems. Sensing systems are necessary for diagnosis and epidemiological control of pathogenic organism, especially in the food-borne pathogen and sanitary water treatment facility' bacterial populations. Bacterial sensing for the purpose of diagnosis can function in three ways: bacterial morphological visualization, specific detection of bacterial component and whole cell detection. This paper provides an overview of the currently available bacterial detection systems that ranges from microscopic observation to state-of-the-art smartphone-based detection.
    Matched MeSH terms: Equipment Design
  11. Gopinath SC, Tang TH, Citartan M, Chen Y, Lakshmipriya T
    Biosens Bioelectron, 2014 Jul 15;57:292-302.
    PMID: 24607580 DOI: 10.1016/j.bios.2014.02.029
    Sensing applications can be used to report biomolecular interactions in order to elucidate the functions of molecules. The use of an analyte and a ligand is a common set-up in sensor development. For several decades, antibodies have been considered to be potential analytes or ligands for development of so-called "immunosensors." In an immunosensor, formation of the complex between antibody and antigen transduces the signal, which is measurable in various ways (e.g., both labeled and label-free based detection). Success of an immunosensor depends on various factors, including surface functionalization, antibody orientation, density of the antibody on the sensor platform, and configuration of the immunosensor. Careful optimization of these factors can generate clear-cut results for any immunosensor. Herein, current aspects, involved in the generated immunosensors, are discussed.
    Matched MeSH terms: Equipment Design
  12. Ahsan MR, Islam MT, Habib Ullah M, Mahadi WN, Latef TA
    ScientificWorldJournal, 2014;2014:909854.
    PMID: 25165750 DOI: 10.1155/2014/909854
    This paper presents a compact sized inset-fed rectangular microstrip patch antenna embedded with double-P slots. The proposed antenna has been designed and fabricated on ceramic-PTFE composite material substrate of high dielectric constant value. The measurement results from the fabricated prototype of the antenna show -10 dB reflection coefficient bandwidths of 200 MHz and 300 MHz with center resonant frequency of 1.5 GHz and 4 GHz, respectively. The fabricated antenna has attained gains of 3.52 dBi with 81% radiation efficiency and 5.72 dBi with 87% radiation efficiency for lower band and upper band, respectively. The measured E- and H-plane radiation patterns are also presented for better understanding. Good agreement between the simulation and measurement results and consistent radiation patterns make the proposed antenna suitable for GPS and C-band applications.
    Matched MeSH terms: Equipment Design*
  13. Chan YJ, Chong MF, Law CL
    Bioresour Technol, 2012 Dec;125:145-57.
    PMID: 23026327 DOI: 10.1016/j.biortech.2012.08.118
    Thermophilic treatment of palm oil mill effluent (POME) was studied in a novel integrated anaerobic-aerobic bioreactor (IAAB). The IAAB was subjected to a program of steady-state operation over a range of organic loading rate (OLR)s, up to 30 g COD/L day in order to evaluate its treatment capacity. The thermophilic IAAB achieved high chemical oxygen demand (COD), biochemical oxygen demand (BOD) and total suspended solids (TSS) removal efficiencies of more than 99% for OLR up to 18.5 g COD/L day. High methane yield of 0.32 LCH(4) (STP)/g COD(removed) with compliance of the final treated effluent to the discharge limit were achieved. This is higher than that of the mesophilic system due to the higher maximum specific growth rate (μ(max)) of the thermophilic microorganisms. Besides, coupling the model of Grau second order model (anaerobic system) with the model of Monod (aerobic system) will completely define the IAAB system.
    Matched MeSH terms: Equipment Design
  14. Ngu H, Wong KK, Law PL
    Water Environ Res, 2012 Apr;84(4):299-304.
    PMID: 22834217
    A circular gravity-phase separator using coalescing medium with cross flow was developed to remove oil and suspended solids from wastewaters. Coalescence medium in the form of inclined plates promotes rising of oil droplets through coalescence and settling of solid particles through coagulation. It exhibits 22.67% higher removal of total suspended solids (TSS) compared to separators without coalescing medium. Moreover, it removed more than 70% of oil compared to conventional American Petroleum Institute separators, which exhibit an average of 33% oil removal. The flowrate required to attain an effluent oil concentration of 10 mg/L (Q(o10)) at different influent oil concentrations (C(io)) can be represented by Q(o10) x 10(-5) = -0.0012C(io) + 0.352. The flowrate required to attain an effluent TSS concentration of 50 mg/L (Q(ss50)) at different influent TSS concentrations (C(iss)) can be represented by Q(ss50) x 10(-5) = 1.0 x 10(6) C(iss)(-2.9576). The smallest removable solid particle size was 4.87 microm.
    Matched MeSH terms: Equipment Design
  15. Chen J, Ahmad R, Suenaga H, Li W, Swain M, Li Q
    J Biomech, 2015 Feb 5;48(3):512-9.
    PMID: 25560272 DOI: 10.1016/j.jbiomech.2014.11.043
    Although implant-retained overdenture allows edentulous patients to take higher occlusal forces than the conventional complete dentures, the biomechanical influences have not been explored yet. Clinically, there is limited knowledge and means for predicting localized bone remodelling after denture treatment with and without implant support. By using finite element (FE) analysis, this article provides an in-silico approach to exploring the treatment effects on the oral mucosa and potential resorption of residual ridge under three different denture configurations in a patient-specific manner. Based on cone beam computerized tomography (CBCT) scans, a 3D heterogeneous FE model was created; and the supportive tissue, mucosa, was characterized as a hyperelastic material. A measured occlusal load (63N) was applied onto three virtual models, namely complete denture, two and four implant-retained overdentures. Clinically, the bone resorption was measured after one year in the two implant-retained overdenture treatment. Despite the improved stability and enhanced masticatory function, the implant-retained overdentures demonstrated higher hydrostatic stress in mucosa (43.6kPa and 39.9kPa for two and four implants) at the posterior ends of the mandible due to the cantilever effect, than the complete denture (33.4kPa). Hydrostatic pressure in the mucosa signifies a critical indicator and can be correlated with clinically measured bone resorption, pointing to severer mandibular ridge resorption posteriorly with implant-retained overdentures. This study provides a biomechanical basis for denture treatment planning to improve long-term outcomes with minimal residual ridge resorption.
    Matched MeSH terms: Equipment Design*
  16. Ng BC, Kleinheyer M, Smith PA, Timms D, Cohn WE, Lim E
    PLoS One, 2018;13(4):e0195975.
    PMID: 29677212 DOI: 10.1371/journal.pone.0195975
    Despite the widespread acceptance of rotary blood pump (RBP) in clinical use over the past decades, the diminished flow pulsatility generated by a fixed speed RBP has been regarded as a potential factor that may lead to adverse events such as vasculature stiffening and hemorrhagic strokes. In this study, we investigate the feasibility of generating physiological pulse pressure in the pulmonary circulation by modulating the speed of a right ventricular assist device (RVAD) in a mock circulation loop. A rectangular pulse profile with predetermined pulse width has been implemented as the pump speed pattern with two different phase shifts (0% and 50%) with respect to the ventricular contraction. In addition, the performance of the speed modulation strategy has been assessed under different cardiovascular states, including variation in ventricular contractility and pulmonary arterial compliance. Our results indicated that the proposed pulse profile with optimised parameters (Apulse = 10000 rpm and ωmin = 3000 rpm) was able to generate pulmonary arterial pulse pressure within the physiological range (9-15 mmHg) while avoiding undesirable pump backflow under both co- and counter-pulsation modes. As compared to co-pulsation, stroke work was reduced by over 44% under counter-pulsation, suggesting that mechanical workload of the right ventricle can be efficiently mitigated through counter-pulsing the pump speed. Furthermore, our results showed that improved ventricular contractility could potentially lead to higher risk of ventricular suction and pump backflow, while stiffening of the pulmonary artery resulted in increased pulse pressure. In conclusion, the proposed speed modulation strategy produces pulsatile hemodynamics, which is more physiologic than continuous blood flow. The findings also provide valuable insight into the interaction between RVAD speed modulation and the pulmonary circulation under various cardiovascular states.
    Matched MeSH terms: Equipment Design
  17. Mansouri M, Gregory SD, Salamonsen RF, Lovell NH, Stevens MC, Pauls JP, et al.
    PLoS One, 2017;12(2):e0172393.
    PMID: 28212401 DOI: 10.1371/journal.pone.0172393
    Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). The SLC emulates the Starling law of the heart to maintain mean pump flow ([Formula: see text]) with respect to mean left ventricular end diastolic pressure (PLVEDm) as the feedback signal. The SLC and CSC were compared using a mock circulation loop to assess their capacity to increase cardiac output during mild exercise while avoiding ventricular suction (marked by a negative PLVEDm) and maintaining circulatory stability during blood loss and severe reductions in left ventricular contractility (LVC). The root mean squared hemodynamic deviation (RMSHD) metric was used to assess the clinical acceptability of each controller based on pre-defined hemodynamic limits. We also compared the in-silico results from our previously published paper with our in-vitro outcomes. In the exercise simulation, the SLC increased [Formula: see text] by 37%, compared to only 17% with the CSC. During blood loss, the SLC maintained a better safety margin against left ventricular suction with PLVEDm of 2.7 mmHg compared to -0.1 mmHg for CSC. A transition to reduced LVC resulted in decreased mean arterial pressure (MAP) and [Formula: see text] with CSC, whilst the SLC maintained MAP and [Formula: see text]. The results were associated with a much lower RMSHD value with SLC (70.3%) compared to CSC (225.5%), demonstrating improved capacity of the SLC to compensate for the varying cardiac demand during profound circulatory changes. In-vitro and in-silico results demonstrated similar trends to the simulated changes in patient state however the magnitude of hemodynamic changes were different, thus justifying the progression to in-vitro evaluation.
    Matched MeSH terms: Equipment Design
  18. Chang XL, Chee PS, Lim EH
    Sci Rep, 2023 Jun 15;13(1):9678.
    PMID: 37322083 DOI: 10.1038/s41598-023-36335-6
    This paper presents a 35.0 × 35.0 × 2.7 mm3 compact, low-profile, and lightweight wearable antenna for on-body wireless power transfer. The proposed antenna can be easily printed on a piece of flexible tattoo paper and transformed onto a PDMS substrate, making the entire antenna structure conform to the human body for achieving a better user experience. Here, a layer of frequency selective surface (FSS) is inserted in between the antenna and human tissue, which has successfully reduced the loading effects of the tissue, with 13.8 dB improvement on the antenna gain. Also, the operating frequency of the rectenna is not affected much by deformation. To maximize the RF-DC conversion efficiency, a matching loop, a matching stub, and two coupled lines are integrated with the antenna for tuning the rectenna so that a wide bandwidth (~ 24%) can be achieved without the use of any external matching networks. Measurement results show that the proposed rectenna can achieve a maximum conversion efficiency of 59.0% with an input power of 5.75 μW/cm2 and can even exceed 40% for a low input power of 1.0 μW/cm2 with a 20 kΩ resistive load, while many other reported rectennas can only achieve a high PCE at a high power density level, which is not always practical for a wearable antenna.
    Matched MeSH terms: Equipment Design
  19. Teoh CY, Lim FS
    Paediatr Anaesth, 2008 Feb;18(2):119-24.
    PMID: 18184242 DOI: 10.1111/j.1460-9592.2007.02385.x
    The Proseal laryngeal mask airway (PLMA) is a relatively new supraglottic airway device with a drain tube to minimize the risk of gastric insufflation and aspiration. We compared introducer tool (IT) and gum elastic bougie (GEB)-guided techniques for insertion of the Proseal LMA in children.
    Matched MeSH terms: Equipment Design
  20. Kwan MK, Chooi WK, Lim HH
    Med J Malaysia, 2004 Dec;59 Suppl F:14-8.
    PMID: 15941155
    Between April 1998 and December 1999, thirty patients with Idiopathic Scoliosis were operated with Multisegmented Hook-Rod System. These patients were operated at the mean age of 16 years and were followed up for a mean of 22.3 months (range 13-34 months). Seven patients had anterior release to increase the curve flexibility followed by second stage posterior instrumentation on the same day. The average operating time for a posterior instrumentation alone and anterior release combined with posterior instrumentation were 270 minutes and 522 minutes respectively. The average blood loss was 2.2 litres for posterior instrumentation alone and 3.3 litres for single day anterior release and posterior surgery. The mean preoperative Cobb's angle was 70 degrees. The mean immediate postoperative and final follow up Cobb's angles were 38 and 42 degrees, which represented an average coronal plane correction of 46.7% and 40.0% respectively. The mean preoperative apical vertebral rotation was 25 degrees, which improved to 15 degrees after the operation. At final follow up, the mean apical vertebra rotation was 20 degrees, which represented a mean apical vertebral rotation correction of 20%. Complications of the procedure included one transient neurological deficit, one infection, one graft site infection and one case of screw cut out. We were able to obtain satisfactory correction of idiopathic scoliosis with the Multisegmented Hook-Rod System.
    Matched MeSH terms: Equipment Design
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links