Displaying publications 161 - 180 of 1043 in total

Abstract:
Sort:
  1. Chai CA, Yeoh WS, Rajandram R, Aung KP, Ong TA, Kuppusamy S, et al.
    Front Surg, 2021;8:659292.
    PMID: 34055868 DOI: 10.3389/fsurg.2021.659292
    Purpose: Guidelines advocate cystoscopy surveillance (CS) for non-muscle invasive bladder cancer (NMIBC) post-resection. However, cystoscopy is operator dependent and may miss upper tract lesions or carcinoma in-situ (CIS). Urine cytology is a common adjunct but lacks sensitivity and specificity in detecting recurrence. A new mRNA biomarker (CxBladder) was compared with urine cytology as an adjunct to cystoscopy in detecting a positive cystoscopy findings during surveillance cystoscopy in our center. Materials and Methods: Consented patients older than 18, undergoing CS for NMIBC, provide paired urine samples for cytology and CxBladder test. Patients with positive cystoscopy findings would undergo re-Trans Urethral Resection of Bladder Tumor (TURBT). Results: Thirty-five patients were enrolled from April to June 2019. Seven contaminated urine samples were excluded. The remaining cohort of 23 (82%) and 5 (18%) females had a mean age of 66.69 (36-89). Eight (29%) patients with positive cystoscopy finding underwent TURBT. All 8 patients also had positive CxBladder result. This shows that CxBladder has a sensitivity and negative predictive value (NPV) of 100%, specificity of 75% and positive predictive value (PPV) of 62% in predicting a positive cystoscopy finding. TURBT Histo-pathological findings showed Low-grade Ta NMIBC in one patient (4%), and 7 (25%) patients had inflammatory changes. Urine cytology was only positive in one patient with a positive cystoscopy finding. This led to a sensitivity of merely 13% and NPV of 74%, while specificity and PPV was 100% in predicting a positive cystoscopy finding. Conclusion: CxBladder had high NPV and sensitivity which accurately predicted suspicious cystoscopy findings leading to further investigation. It has great potential for use as adjunct to cystoscopy for surveillance of NMIBC.
    Matched MeSH terms: Sensitivity and Specificity
  2. Suzana S, Siti Saifa H
    Malays J Nutr, 2007 Mar;13(1):29-44.
    PMID: 22692187 MyJurnal
    This cross sectional study was conducted to determine the validity of three screening tools, Mini Nutritional Assessment Short Form (MNA-SF), Malnutrition Risk Screening Tool for Community (MRST-C) and Malnutrition Risk Screening Tool for Hospital (MRST-H) among elderly people at health clinics. The screening tools were validated against anthropometric and functional assessments. The anthropometric assessments that were carried out included body weight, height, arm span, body mass index (BMI), calf circumference (CC) and mid upper arm circumference (MUAC). A set of questionnaire on manual dexterity, muscular strength, instrumental activities daily living (IADL) and cognitive status was used to assess functional abilities. A total of 156 subjects were recruited from rural (38 subjects) and urban (118 subjects) health clinics at Sabak Bernam and Cheras respectively. Subjects' age ranged from 60 to 83 years old, with 44.2% were men and 55.8% women. The prevalence of muscle wasting among the subjects assessed from MUAC and CC were both 7.0%. MNA-SF had the highest correlation with BMI (r = 0.497, p<0.001), followed by MUAC (r = 0.398, p<0.001), CC (r = 0.473, p<0.001), cognitive assessment (r = 0.229, p<0.001) and handgrip strength (r = 0.209, p<0.001). Whilst MRST-C had the highest correlation with IADL score (r =-0.320, p<0.001) and MRST-H had the highest correlation with the lock and key test (r = -0.325, p<0.01). Sensitivity was the highest for MNA-SF (93.2%), followed by MRST-H (52.5%) and MRST-C (25.8%). Specificity was the highest for MRST-H (97.3%), followed by MRST-C (90.8%) and MNA-SF (79.4%). Positive predictive value (PPV) for MRST-H, MNA-SF and MRST-C was 55.5%, 18.2% and 14.1%, respectively. In conclusion, among the screening tools being validated, MNA-SF is considered the most appropriate tool to be used in health clinics for identification of elderly individuals who are at high risk of malnutrition.
    Matched MeSH terms: Sensitivity and Specificity
  3. Nor Azian, M.Z., Suzana, S., Romzi, M.A.
    Malays J Nutr, 2014;20(2):209-219.
    MyJurnal
    Introduction: Nutrition screening is recommended as a first step of nutrition care to allow early identification and intervention of malnourished patients. The present study determined the validities and reliabilities of two malnutrition screening tools namely, the Malnutrition Universal Screening Tool (MUST) and Malnutrition Screening Tool (MST) among adult patients at the Hospital Kuala Lumpur. Methods: The sensitivity, specificity and predictive value of MUST and MST were conducted against the Subjective Global Assessment (SGA), anthropometric parameters including body mass index (BMI), calf circumference (CC), mid-upper arm circumference (MUAC) and energy intake. Inter-rater reliability was evaluated using kappa value (κ) to determine the level of agreement between raters. Results: A total of 151 subjects with mean age of 45.2 ± 13.7 years participated in this study. Prevalence of malnutrition according to MUST, MST and SGA was 34.4%, 33.8% and 19.9%, respectively. As compared to SGA, MUST and MST had a sensitivity of 96.6% and 93.3% respectively, whereas the specificity was 80.9% for both tools. The sensitivity and specificity of MUST against the anthropometric parameters (BMI, CC and MUAC) were between 53.8% to 88.8% and 67.4% to 69.9%, respectively. The sensitivity values for MST were between 46.1% to 63.6% and specificity values were between 64.4% to 67.6%. The inter-rater reliability of MUST was higher (substantial, mean (κ) = 0.78) than for MST (moderate, mean (κ) = 0.52). Conclusions: In conclusion, MUST was found to have similar validity levels but higher reliability result than MST. Based on our result, MUST is recommended for use in identifying adult patients who are at high risk of malnutrition. It can be used as a malnutrition screening tool but there is a need to evaluate the cost effectiveness of its implementation.
    Matched MeSH terms: Sensitivity and Specificity
  4. Neela V, Thomas R, Rankouhi SZR, Karunanidhi A, Shueh CS, Hamat RA, et al.
    J Med Microbiol, 2012 Dec;61(Pt 12):1792-1794.
    PMID: 22956752 DOI: 10.1099/jmm.0.049403-0
    Matched MeSH terms: Sensitivity and Specificity
  5. Navaratnam V, Mordi MN, Mansor SM
    J Chromatogr B Biomed Sci Appl, 1997 Apr 25;692(1):157-62.
    PMID: 9187395
    A selective reproducible high-performance liquid chromatographic assay for the simultaneous quantitative determination of the antimalarial compound artesunic acid (ARS), dihydroartemisinin (DQHS) and artemisinin (QHS), as internal standard, is described. After extraction from plasma, ARS and DQHS were analysed using an Econosil C8 column and a mobile phase of acetonitrile-0.05 M acetic acid (42:58, v/v) adjusted to pH 5.0 and electrochemical detection in the reductive mode. The mean recovery of ARS and DQHS over a concentration range of 50-200 ng/ml was 75.5% and 93.5%, respectively. The within-day coefficients of variation were 4.2-7.4% for ARS and 2.6-4.9% for DQHS. The day-to-day coefficients of variation were 1.6-9.6% and 0.5-8.3%, respectively. The minimum detectable concentration for ARS and DQHS in plasma was 4.0 ng/ml for both compounds. The method was found to be suitable for use in clinical pharmacological studies.
    Matched MeSH terms: Sensitivity and Specificity
  6. Yap SP, Julianto T, Wong JW, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1999 Dec 10;735(2):279-83.
    PMID: 10670741
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of vitamin E especially delta-, gamma- and alpha-tocotrienols in human plasma. The method entailed direct injection of plasma sample after deproteinization using a 3:2 mixture of acetonitrile-tetrahydrofuran. The mobile phase comprised 0.5% (v/v) of distilled water in methanol. Analyses were run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 296 nm and emission wavelength of 330 nm. This method is specific and sensitive, with a quantification limit of approximately 40, 34 and 16 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. The mean absolute recovery values were about 98% while the within-day and between-day relative standard deviation and percent error values of the assay method were all less than 12.0% for alpha-, gamma- and delta-tocotrienol. The calibration curve was linear over a concentration range of 40-2500, 30-4000 and 16-1000 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. Application of the method in a bioavailability study for determination of the above compounds was also demonstrated.
    Matched MeSH terms: Sensitivity and Specificity
  7. Peh KK, Billa N, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1997 Nov 07;701(1):140-5.
    PMID: 9389350
    A simple liquid chromatographic method using amperometric detection was developed for the determination of naltrexone in human plasma. Prior to analysis, naltrexone and the internal standard (naloxone) were extracted from plasma samples using a 9:1 mixture of chloroform and isopropyl alcohol. The mobile phase comprised 0.1 M disodium hydrogen orthophosphate (pH 3.5) and acetonitrile (85.5:14.5, v/v). Analysis was run at a flow-rate of 0.8 ml/min with the detector operating under oxidative mode at an applied potential of +0.95 V. The method is specific and sensitive with a detection limit of approximately 1 ng/ml at a signal-to-noise ratio of 3:1. Mean recovery value of the extraction procedure was about 93%, while the within day and between day coefficient of variation and percent error values of the assay method were all less than 10%. The calibration curve was linear over a concentration range of 1.5-100 ng/ml.
    Matched MeSH terms: Sensitivity and Specificity
  8. Wong CF, Peh KK, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1998 Oct 23;718(1):205-10.
    PMID: 9832378
    A simple high-performance liquid chromatographic method was developed for the determination of ranitidine in human plasma. Prior to analysis, ranitidine and the internal standard (metoprolol) were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M potassium dihydrogenphosphate-acetonitrile (88:12, v/v) adjusted to pH 6.5. Analysis was run at a flow-rate of 1.3 ml/min and at a detection wavelength of 229 nm. The method is sensitive with a detection limit of 1 ng/ml at a signal-to-noise ratio of 3:1, while the quantification limit was set at 15 ng/ml. The calibration curve was linear over a concentration range of 15-2000 ng/ml. Mean recovery value of the extraction procedure was about 90%, while the within-day and between-day coefficients of variation and percent error values of the assay method were all less than 15%.
    Matched MeSH terms: Sensitivity and Specificity
  9. Mohd Zaki F, Moineddin R, Grant R, Chavhan GB
    Pediatr Radiol, 2016 Nov;46(12):1684-1693.
    PMID: 27406610
    BACKGROUND: Safety concerns are increasingly raised regarding the use of gadolinium-based contrast media for MR imaging.

    OBJECTIVE: To determine the accuracy of pre-contrast abdominal MR imaging for lesion detection and characterization in pediatric oncology patients.

    MATERIALS AND METHODS: We included 120 children (37 boys and 83 girls; mean age 8.94 years) referred by oncology services. Twenty-five had MRI for the first time and 95 were follow-up scans. Two authors independently reviewed pre-contrast MR images to note the following information about the lesions: location, number, solid vs. cystic and likely nature. Pre- and post-contrast imaging reviewed together served as the reference standard.

    RESULTS: The overall sensitivity was 88% for the first reader and 90% for the second; specificity was 94% and 91%; positive predictive value was 96% and 94%; negative predictive value was 82% and 84%; accuracy of pre-contrast imaging for lesion detection as compared to the reference standard was 90% for both readers. The difference between mean number of lesions detected on pre-contrast imaging and reference standard was not significant for either reader (reader 1, P = 0.072; reader 2, P = 0.071). There was substantial agreement (kappa values of 0.76 and 0.72 for readers 1 and 2) between pre-contrast imaging and reference standard for determining solid vs. cystic lesion and likely nature of the lesion. The addition of post-contrast imaging increased confidence of both readers significantly (P 

    Matched MeSH terms: Sensitivity and Specificity
  10. Nik Muhamad, N.A., anesan Murthi, J., Nik Ismail, N.A.
    Medicine & Health, 2015;10(2):103-111.
    MyJurnal
    The popularity of ultrasound for acute diagnosis of fractures in the Emergency Department (ED) has increased over the recent years. This present study aimed to determine the sensitivity and specificity of ultrasound use for detection of fractures in a different environment, which is at the triage area of the ED. We compared the results of bedside ultrasound in detecting non-critical fractures to the current gold standard of X-rays in the triage area. The design was a single centered crosssectional study. From August 2014 till November 2014, a total of 46 patients were recruited, creating 75 image pairs. Following consent, a bedside ultrasound was performed and subsequently compared with X-ray reporting regarding the presence or absence of fractures. SPSS analysis was used to determine the sensitivity and specificity of ultrasound in diagnosing fracture as compared to X-rays. Ultrasound had a sensitivity of 72% (95% CI, 50.6% - 87.9%) and a specificity of 80% (95%CI: 66.3 - 90%) when compared to X-rays in fracture diagnosis. The kappa analyses showed moderate inter observer agreement (0.5) between ultrasound and X-rays in diagnosing fractures. This study suggests that the use of ultrasound as a triage tool yet has unacceptable sensitivity and needs further evaluation and consideration.
    Matched MeSH terms: Sensitivity and Specificity
  11. Lau S, Ng KH, Abdul Aziz YF
    Br J Radiol, 2016 Oct;89(1066):20160258.
    PMID: 27452264 DOI: 10.1259/bjr.20160258
    OBJECTIVE: To investigate the sensitivity and robustness of a volumetric breast density (VBD) measurement system to errors in the imaging physics parameters including compressed breast thickness (CBT), tube voltage (kVp), filter thickness, tube current-exposure time product (mAs), detector gain, detector offset and image noise.

    METHODS: 3317 raw digital mammograms were processed with Volpara(®) (Matakina Technology Ltd, Wellington, New Zealand) to obtain fibroglandular tissue volume (FGV), breast volume (BV) and VBD. Errors in parameters including CBT, kVp, filter thickness and mAs were simulated by varying them in the Digital Imaging and Communications in Medicine (DICOM) tags of the images up to ±10% of the original values. Errors in detector gain and offset were simulated by varying them in the Volpara configuration file up to ±10% from their default values. For image noise, Gaussian noise was generated and introduced into the original images.

    RESULTS: Errors in filter thickness, mAs, detector gain and offset had limited effects on FGV, BV and VBD. Significant effects in VBD were observed when CBT, kVp, detector offset and image noise were varied (p 

    Matched MeSH terms: Sensitivity and Specificity
  12. Lange B, Khan P, Kalmambetova G, Al-Darraji HA, Alland D, Antonenka U, et al.
    Int J Tuberc Lung Dis, 2017 05 01;21(5):493-502.
    PMID: 28399963 DOI: 10.5588/ijtld.16.0702
    SETTING: Xpert® MTB/RIF is the most widely used molecular assay for rapid diagnosis of tuberculosis (TB). The number of polymerase chain reaction cycles after which detectable product is generated (cycle threshold value, CT) correlates with the bacillary burden.OBJECTIVE To investigate the association between Xpert CT values and smear status through a systematic review and individual-level data meta-analysis.

    DESIGN: Studies on the association between CT values and smear status were included in a descriptive systematic review. Authors of studies including smear, culture and Xpert results were asked for individual-level data, and receiver operating characteristic curves were calculated.

    RESULTS: Of 918 citations, 10 were included in the descriptive systematic review. Fifteen data sets from studies potentially relevant for individual-level data meta-analysis provided individual-level data (7511 samples from 4447 patients); 1212 patients had positive Xpert results for at least one respiratory sample (1859 samples overall). ROC analysis revealed an area under the curve (AUC) of 0.85 (95%CI 0.82-0.87). Cut-off CT values of 27.7 and 31.8 yielded sensitivities of 85% (95%CI 83-87) and 95% (95%CI 94-96) and specificities of 67% (95%CI 66-77) and 35% (95%CI 30-41) for smear-positive samples.

    CONCLUSION: Xpert CT values and smear status were strongly associated. However, diagnostic accuracy at set cut-off CT values of 27.7 or 31.8 would not replace smear microscopy. How CT values compare with smear microscopy in predicting infectiousness remains to be seen.

    Matched MeSH terms: Sensitivity and Specificity
  13. Amran, A.R., Fatimah, M.
    MyJurnal
    Introduction: Mammography is commonly regarded as the single most important tool for screening and for early detection of breast cancer. However it is not generally recommended for women under 40 years of age and in those taking hormone replacement therapy as the increased density of the breast parenchyma may make mammography more difficult to read and interpret. The limitations of mammography have spurred attempts to find new techniques that can be used either separately or in conjunction with mammography. Purpose: The aim of this study was to quantify the clinical value of using electrical impedance scanning (EIS) or Trans Scan as an adjunct to mammography in order to identify cancerous tissue based upon its inherent altered local dielectric properties. Methods and Materials: The patients were examined using Trans Scan (Trans Scan Medical, Ltd., distributed by Siemens AG. The study population was derived from patients with suspicious breast lesions categorized as BIRADS 3 or 4 detected during mammography or ultrasound. Results: Fifty-three women with 53 mammographically and/or sonographically suspicious findings were examined using EIS. With respect to the histopathological findings (15 malignant and 38 benign lesions) 13 of 15 (86.6% sensitivity) malignant lesions were correctly identified using EIS whereas, 33 of 38 (81.5% specificity) benign lesions were correctly identified. Negative and positive predictive values of 93.9% and 65% were observed respectively. Two benign lesions were correctly identified in a dense breast. The smallest lesion detected in this study measured 20 x 14 mm, which was an infiltrating ductal carcinoma. Conclusion: Electrical impedance scanning as an adjunct to mammography or ultrasound in classifying suspicious lesions is promising because it increases the sensitivity for cancer detection and may reduce biopsy of equivocal lesions. The additional use of EIS with negative predictive value of 93.9% may be useful to exclude some benign lesions from further diagnostic or invasive procedures. Artifacts, such as signals from superficial skin lesions, poor contact and bubbles are currently a limitation
    Matched MeSH terms: Sensitivity and Specificity
  14. Yunus A, Seet W, Md Adam B, Jamaiyah H
    Malays Fam Physician, 2013;8(1):5-11.
    PMID: 25606261 MyJurnal
    Objective: To validate the Malay version of Berlin Questionnaire (BQ) as a tool to screen for patients at risk of obstructive sleep apnea (OSA) in primary care Background: Most patients with OSA are unrecognised and untreated. Thus, the BQ has been used as a tool to screen for patients at risk for OSA. However, this tool has not been validated in Malay version. Materials and Methods: A parallel back-to-back translation method was applied to produce the Malay version (Berlin-M). The Malay version was administered to 150 patients in a tertiary respiratory medical centre.  Concurrent validity of the Berlin-M was determined using the Apnea Hypopnea Index (AHI) as the gold standard measure. The test-retest reliability and internal consistency of the Berlin-M were determined. Results: Most patients were males (64.0%) and majority of them were Malays (63.3%). Based on the sleep study test, 121 (84.0%) were classified as high risk while 23 (16.0%) as low risk using the Apnea Hypopnea Index (AHI) ≥5 as the cutoff point. The test–retest reliability Kappa value showed a good range between 0.864 – 1.000. The Cronbach’s alpha of BQ was 0.750 in category 1 and 0.888 in category 2. The sensitivity and specificity were 92% and 17% respectively. Conclusion: The BQ showed high sensitivity (92%) but low specificity (17%). Therefore, though the Berlin-M is useful as a screening tool, it is not a confirmatory diagnostic tool.
    Matched MeSH terms: Sensitivity and Specificity
  15. Zuraida Zainun, Mohd Normani Zakaria, Din Suhaimi Sidek, Zalina Ismail
    MyJurnal
    Peripheral vestibular disorder (PVD) is serious and common. Clinically, giving an accurate diagnosis of PVD can be challenging. Vestibular evoked myogenic potential (VEMP) is an objective test to evaluate the integrity of vestibular organs, particularly saccule and/or inferior vestibular nerve. This study was performed to determine the sensitivity and specificity of VEMP using different stimuli. Fourty normal and 65 PVD subjects who fulfilled the inclusion criteria were recruited. While sitting comfortably, VEMP waveforms were recorded with active electrode on sternocleidomastoid muscle and negative electrode on upper forehead. Tone bursts (500, 750 and 1000 Hz) were delivered via headphones at 90 dBnHL and 5/s presentation rate. VEMP parameters for each stimulus (amplitude and latency of P1 and N1 peak) were analyzed accordingly. Receiver operating characteristic (ROC) was performed to determine the sensitivity and specificity of VEMP at different test frequencies. N1 amplitude of 750 Hz stimulus produced the most ideal sensitivity (65% on right and 63% on left) and specificity (83% on right and 78% on left). The importance of using a few tone bursts in VEMP test in order to minimize the false negative in cases might be encountered in clinics as the certain tone burst had inadequate sensitivity in detecting PVD cases. The 750 Hz stimulus produced the most ideal VEMP with adequate values of sensitivity and specificity, at least in this study.
    Matched MeSH terms: Sensitivity and Specificity
  16. Siti Raudzah Ghazali, Elklit, Ask, Rekaya Vincent Balang, Ameenudeen Sultan, M., Yoke, Yong Chen
    ASEAN Journal of Psychiatry, 2014;15(2):146-152.
    MyJurnal
    Objective: The objective of this study is to determine the optimal cut-off score for the Centre for Epidemiologic Studies Depression scale (CESD) according to Malaysian adolescent norms. Methods: This is a cross-sectional study. Nine hundred and thirty-one adolescents aged 13 to 17 years-old completed the CESD and Hopkins Symptom Checklist-depression scale (HSCL-depression). Results: Results from the receiver operating characteristic (ROC) curve, kappa coefficients and odds ratio analysis showed that CESD cut-off score of 27 was suitable to be used according to Malaysian norms, demonstrating a specificity of 93%. Conclusion: The findings suggest a cut-off score 27 should be used for screening of depression for Malaysian adolescents using the CESD. ASEAN Journal of Psychiatry, Vol. 15 (2): July - December 2014: 146-152.
    Matched MeSH terms: Sensitivity and Specificity
  17. Loke, S.T.
    Malaysian Dental Journal, 2007;28(1):24-31.
    MyJurnal
    Introduction: There is generally inconsistent appropriate orthodontic referral among local dentists. Orthodontic indices are not routinely used to assess the need for treatment. The aim of this pilot study is to evaluate the efficacy of the Index of Orthodontic Treatment Need (IOTN) as an educational tool to improve their ability to assess orthodontic treatment need.

    Methodology: Local dental officers assessed 30 study models on two occasions (before and after IOTN training) and their findings compared with an expert group for agreement in IOTN scores and referral decisions. Training comprised oral/visual presentation, instruction manuals, ‘hands-on’ and self-study. Kappa statistic (?) was used to assess agreement.

    Results: As a group there was no significant improvement in referral decisions after training with only ‘moderate’ agreement (?=0.47), although half of the subjects improved. Agreement was better with aesthetic (?=0.51) than functional (?=0.41) assessment. ‘Sensitivity’ was 82.4% and ‘Specificity’ was 58.2% but both were not statistically significant before and after training.

    Conclusion: The IOTN has potential as an educational tool for improving the diagnostic skills of dental officers. More accurate assessment of the Dental Health Component with the IOTN ruler and familiarity with the Aesthetic Component has to be emphasized in future training.
    Matched MeSH terms: Sensitivity and Specificity
  18. Chin ZH
    MyJurnal
    Rural health clinics in Sri Aman Division in Sarawak, Malaysia lack diagnostic tests for malaria. Many of the medical assistants in the clinic diagnose malaria solely on clinical ground. The study was to determine the sensitivity, specificity and positive predictive value of clinical diagnosis of rnahtria made by medical assistants using results of microscopy examination as gold standard. The study period was from September to December 2003. Three rural clinics without laboratory or diagnostic tests services and one urban clinic with laboratory facility serving malarious areas were selected. All patients clinically diagnosed as malaria by the attending medical assistants were included as clinical malaria cases. Blood slides were taken for examination of malaria parasites. Non clinical malaria cases were all other patients without clinical malaria for whom blood slides were taken for malaria parasites. Out of 362 patients included in the study, 75 were clinically diagnosed as having mahria. The sensitivity of headache, history of fever and chills/rigors to detect malaria cases was above 90% but the specificity and positive predictive value was low, below 40% and 20% respectively. The sensitivity, specificity and positive predictive value of malaria clinical diagnosis made by medical assistants was 82.1 %, 84 .4% and 30.7% respectively. Clinical diagnosis of malaria increases the slide positive rate by four folds. However the sensitivity, specincity and positive predictive value of clinical diagnosis by medical assistant and clinical characteristics was insufficient to enable each of them to be used alone to differentiate true malaria cases from non mahiria cases.
    Matched MeSH terms: Sensitivity and Specificity
  19. Norlijah Othman, Nor Khamisah, A., Kamarul Azhar, Sinniah, Mangalam, Lekhraj, Rampal
    MyJurnal
    Dengue haemorrhagic fever (DHF) is a severe viral illness with significant morbidity and mortality especially among children in Southeast Asia. The tourniquet test is recommended by the World Health Organisation (WHO) as an initial clinical screening procedure for patients suspected to have DHF, particularly in patients with DHF grade I. The aim of this study was to evaluate the validity of the tourniquet test as a predictor of DHF and also to assess the usefulness of repeated, serial tourniquet testing as a diagnostic indicator of DHF. Individuals included into this study were children from the Institute of Paediatrics, Kuala Lumpur who were admitted on a clinical suspicion of DHF based on the WHO criteria and who had serology for Dengue IgM performed. A standard method of tourniquet was performed on these patients on a daily basis following admission. A total number of 60 patients were considered for analysis and of these the tourniquet test was positive in 50 patients and negative in the remaining 10 patients. Sensitivity of the test was found to be 85.4% and the specificity was 25%. Further assessment of the predictive value of the test showed that the positive predictive value (PPV) was 82% while the negative predictive value (NPV) was 30%. In conclusion, a positive tourniquet test, serially performed on a daily basis was found clinically to be a useful preliminary screening tool for DHF as recommended by WHO. However its specificity was low and consequently led to a high false positive rate.
    Matched MeSH terms: Sensitivity and Specificity
  20. Anthony, Leela, Ambu, Stephen, Lokman Hakim, Lee, Nagarajah
    MyJurnal
    Background: Database on hospital records like discharge data, birth and death certificates are widely used for epidemiological and research studies. However there are a very few validation studies on these data. The aim of this study was to validate and assess the accuracy of the ICD 10 database on congenital anomalies in the state of Penang. This study was carried out for three years, from 2002 to 2004.

    Methods: The list of cases coded under the general coding “Q” was extracted and approximately 30% of cases were randomly selected from the list. Medical records for the selected cases were checked and discrepancies for the diagnoses between the medical records and the ICD 10 data base were recorded for three years. Verification was done for basic demographic variables and the coding of the diseases. Discrepancies, sensitivity and specificity were calculated.

    Results: The ICD 10 database for congenital anomalies are classified into two types: Type 1 and Type 2. Discrepancies on demographic information were found among the age of patients (babies with congenital anomalies). In Type 1, there was a discrepancy of about 0.02 % to 0.05% probability that a congenital anomaly case can be recorded as non congenital anomaly in the ICD 10. In Type 2 there was a discrepancy that a non-congenital anomaly was classified as congenital anomaly and this ranged from 26.7% to 50.0%. The sensitivity ranged from 96.85% to 97.98%, thus it can be concluded the ICD 10 database is highly sensitive while the specificity ranged from 50.00% to 78.57 %. In other words the ICD 10 is not accurate when classifying the non- congenital anomaly cases. A fair percentage of non-congenital anomaly cases were classified as CA in the ICD 10 database.

    Conclusion: Even though hospital databases are used as a baseline data for a number of research and epidemiological studies it cannot be used at face value. Validation of these data is necessary before any conclusions can be drawn or intervention measures are undertaken.
    Matched MeSH terms: Sensitivity and Specificity