Displaying publications 1 - 20 of 48 in total

Abstract:
Sort:
  1. Lee FW, Chai HK, Lim KS
    Sensors (Basel), 2016;16(3).
    PMID: 26959028 DOI: 10.3390/s16030337
    An improved single sided Rayleigh wave (R-wave) measurement was suggested to characterize surface breaking crack in steel reinforced concrete structures. Numerical simulations were performed to clarify the behavior of R-waves interacting with surface breaking crack with different depths and degrees of inclinations. Through analysis of simulation results, correlations between R-wave parameters of interest and crack characteristics (depth and degree of inclination) were obtained, which were then validated by experimental measurement of concrete specimens instigated with vertical and inclined artificial cracks of different depths. Wave parameters including velocity and amplitude attenuation for each case were studied. The correlations allowed us to estimate the depth and inclination of cracks measured experimentally with acceptable discrepancies, particularly for cracks which are relatively shallow and when the crack depth is smaller than the wavelength.
    Matched MeSH terms: Electromagnetic Phenomena
  2. Elias BBQ, Soh PJ, Al-Hadi AA, Akkaraekthalin P, Vandenbosch GAE
    Sensors (Basel), 2021 Apr 04;21(7).
    PMID: 33916507 DOI: 10.3390/s21072516
    This work presents the design and optimization of an antenna with defected ground structure (DGS) using characteristic mode analysis (CMA) to enhance bandwidth. This DGS is integrated with a rectangular patch with circular meandered rings (RPCMR) in a wearable format fully using textiles for wireless body area network (WBAN) application. For this integration process, both CMA and the method of moments (MoM) were applied using the same electromagnetic simulation software. This work characterizes and estimates the final shape and dimensions of the DGS using the CMA method, aimed at enhancing antenna bandwidth. The optimization of the dimensions and shape of the DGS is simplified, as the influence of the substrates and excitation is first excluded. This optimizes the required time and resources in the design process, in contrast to the conventional optimization approaches made using full wave "trial and error" simulations on a complete antenna structure. To validate the performance of the antenna on the body, the specific absorption rate is studied. Simulated and measured results indicate that the proposed antenna meets the requirements of wideband on-body operation.
    Matched MeSH terms: Electromagnetic Phenomena
  3. Hidayah Mansor, Razi Abdul-Rahman
    MyJurnal
    Introduction: For “smart health” Internet-of-Things (IoT) applications, substrate integrated waveguide (SIW) is a promising component to construct a wearable microwave device. For its efficacy in wearable devices, minimizing signal losses in terms of return and transition losses in SIW is of paramount importance. To enhance its performance, this paper presents the characterization of air-filled SIW transition losses for the SIW microwave device. Method: To investigate the effect of transition length on losses, the full-wave analysis of an air-filled SIW with different lengths of the taper transition was presented. For the analysis, the linear taper is designed for the Roger RT/Duroid 6002 substrate and utilized in the Ka-band frequencies. Result: From the full-wave analysis results, the length of the tran- sition taper can be reduced considerably while achieving a wide-bandwidth characteristic of return loss better than 20 GHz. The results also show that the transmission loss can be reliably reduced while reducing the size of the SIW component. Conclusion: The findings may contribute to the development of the compact design of wearable micro- wave devices having a comparable performance with the conventional waveguide.
    Matched MeSH terms: Electromagnetic Phenomena
  4. Nazatulsyima Mohd Yazid, Kim, Gaik Tay, Wei, King Tiong, Yaan, Yee Choy, Azila Md Sudin, Chee, Tiong Ong
    MATEMATIKA, 2017;33(1):35-41.
    MyJurnal
    In this paper, the application of the method of lines (MOL) to the Forced
    Korteweg-de Vries-Burgers equation with variable coefficient (FKdVB) is presented.
    The MOL is a powerful technique for solving partial differential equations by typically
    using finite-difference approximations for the spatial derivatives and ordinary differential
    equations (ODEs) for the time derivative. The MOL approach of the FKdVB
    equation leads to a system of ODEs. The solution of the system of ODEs is obtained
    by applying the Fourth-Order Runge-Kutta (RK4) method. The numerical solution
    obtained is then compared with its progressive wave solution in order to show the
    accuracy of the MOL method.
    Matched MeSH terms: Electromagnetic Phenomena
  5. Al-Bawri SS, Islam MS, Wong HY, Jamlos MF, Narbudowicz A, Jusoh M, et al.
    Sensors (Basel), 2020 Jan 14;20(2).
    PMID: 31947533 DOI: 10.3390/s20020457
    A multiband coplanar waveguide (CPW)-fed antenna loaded with metamaterial unit cell for GSM900, WLAN, LTE-A, and 5G Wi-Fi applications is presented in this paper. The proposed metamaterial structure is a combination of various symmetric split-ring resonators (SSRR) and its characteristics were investigated for two major axes directions at (x and y-axis) wave propagation through the material. For x-axis wave propagation, it indicates a wide range of negative refractive index in the frequency span of 2-8.5 GHz. For y-axis wave propagation, it shows more than 2 GHz bandwidth of near-zero refractive index (NZRI) property. Two categories of the proposed metamaterial plane were applied to enhance the bandwidth and gain. The measured reflection coefficient (S11) demonstrated significant bandwidths increase at the upper bands by 4.92-6.49 GHz and 3.251-4.324 GHz, considered as a rise of 71.4% and 168%, respectively, against the proposed antenna without using metamaterial. Besides being high bandwidth achieving, the proposed antenna radiates bi-directionally with 95% as the maximum radiation efficiency. Moreover, the maximum measured gain reaches 6.74 dBi by a 92.57% improvement compared with the antenna without using metamaterial. The simulation and measurement results of the proposed antenna show good agreement.
    Matched MeSH terms: Electromagnetic Phenomena
  6. Ali Esmail B, Majid HA, Zainal Abidin Z, Haimi Dahlan S, Himdi M, Dewan R, et al.
    Materials (Basel), 2020 Jan 26;13(3).
    PMID: 31991912 DOI: 10.3390/ma13030582
    In this research, a reconfigurable metamaterial (MM) structure was designed using a millimeter-wave (MMW) band with two configurations that exhibit different refractive indices. These two MM configurations are used to guide the antenna's main beam in the desired direction in the 5th generation (5G) band of 28 GHz. The different refractive indices of the two MM configurations created phase change for the electromagnetic (EM) wave of the antenna, which deflected the main beam. A contiguous squares resonator (CSR) is proposed as an MM structure to operate at MMW band. The CSR is reconfigured using three switches to achieve two MM configurations with different refractive indices. The simulation results of the proposed antenna loaded by MM unit cells demonstrate that the radiation beam is deflected by angles of +30° and -27° in the E-plane, depending on the arrangement of the two MM configurations on the antenna substrate. Furthermore, these deflections are accompanied by gain enhancements of 1.9 dB (26.7%) and 1.5 dB (22.4%) for the positive and negative deflections, respectively. The reflection coefficients of the MM antenna are kept below -10 dB for both deflection angles at 28 GHz. The MM antennas are manufactured and measured to validate the simulated results.
    Matched MeSH terms: Electromagnetic Phenomena
  7. Sathik MJ, Almakhles DJ, Sandeep N, Siddique MD
    Sci Rep, 2021 Mar 03;11(1):5067.
    PMID: 33658562 DOI: 10.1038/s41598-021-84531-z
    Multilevel inverters play an important role in extracting the power from renewable energy resources and delivering the output voltage with high quality to the load. This paper proposes a new single-stage switched capacitor nine-level inverter, which comprises an improved T-type inverter, auxiliary switch, and switched cell unit. The proposed topology effectively reduces the DC-link capacitor voltage and exhibits superior performance over recently switched-capacitor inverter topologies in terms of the number of power components and blocking voltage of the switches. A level-shifted multilevel pulse width modulation scheme with a modified triangular carrier wave is implemented to produce a high-quality stepped output voltage waveform with low switching frequency. The proposed nine-level inverter's effectiveness, driven by the recommended modulation technique, is experimentally verified under varying load conditions. The power loss and efficiency for the proposed nine-level inverter are thoroughly discussed with different loads.
    Matched MeSH terms: Electromagnetic Phenomena
  8. Daura LU, Tian G, Yi Q, Sophian A
    Philos Trans A Math Phys Eng Sci, 2020 Oct 16;378(2182):20190579.
    PMID: 32921233 DOI: 10.1098/rsta.2019.0579
    Eddy current testing (ECT) has been employed as a traditional non-destructive testing and evaluation (NDT&E) tool for many years. It has developed from single frequency to multiple frequencies, and eventually to pulsed and swept-frequency excitation. Recent progression of wireless power transfer (WPT) and flexible printed devices open opportunities to address challenges of defect detection and reconstruction under complex geometric situations. In this paper, a transmitter-receiver (Tx-Rx) flexible printed coil (FPC) array that uses the WPT approach featuring dual resonance responses for the first time has been proposed. The dual resonance responses can provide multiple parameters of samples, such as defect characteristics, lift-offs and material properties, while the flexible coil array allows area mapping of complex structures. To validate the proposed approach, experimental investigations of a single excitation coil with multiple receiving coils using the WPT principle were conducted on a curved pipe surface with a natural dent defect. The FPC array has one single excitation coil and 16 receiving (Rx) coils, which are used to measure the dent by using 21 C-scan points on the dedicated dent sample. The experimental data were then used for training and evaluation of dual resonance responses in terms of multiple feature extraction, selection and fusion for quantitative NDE. Four features, which include resonant magnitudes and principal components of the two resonant areas, were investigated for mapping and reconstructing the defective dent through correlation analysis for feature selection and feature fusion by deep learning. It shows that deep learning-based multiple feature fusion has outstanding performance for 3D defect reconstruction of WPT-based FPC-ECT. This article is part of the theme issue 'Advanced electromagnetic non-destructive evaluation and smart monitoring'.
    Matched MeSH terms: Electromagnetic Phenomena
  9. Ramachandran T, Faruque MRI, Islam MT
    Sci Rep, 2021 Feb 19;11(1):4270.
    PMID: 33608595 DOI: 10.1038/s41598-021-83715-x
    This study explores the effect of symmetrical square shaped metamaterial design for microwave frequency applications. The latest technology demands of advanced performance and research studies of metamaterial integration in the related bands are increasing tremendously. Therefore, this motivates us to explore the metamaterial design structure that has a high possibility to be applied in more than two resonance bands using a compact design structure. This study emphasis on a compact 14 × 14 mm2 and 1.524 mm thick substrate material known as Rogers RT6002. Seven distinct square shaped metamaterial (SQM) rings were constructed on the substrate material to achieve the goal of this research study. Besides that, the investigations of the metamaterial electromagnetic properties and effective medium parameters were carried out by utilising the Computer Simulation Technology Microwave Studio (CST) software. According to the numerical simulation results, the proposed SQM unit cell manifested quintuple resonance frequencies precisely at 3.384 (S band), 5.436, 7.002 (C band), 11.664 (X band), and 17.838 GHz (Ku band). Meanwhile, for the validation process, the comparison between the simulation and measurement results was analysed and data showed that the first and third resonance frequencies were increased by 0.336 and 0.139 GHz, respectively while other frequencies were reduced by 0.186, 0.081, and 0.709 GHz in sequential order. The numerical simulation of the metamaterial design was conducted in a High Frequency Structure Simulator (HFSS) to further validate the results. Furthermore, the proposed SQM manifested left handed characteristics at the second to fifth resonance bands. In a nutshell, the SQM successfully achieves the objectives of this research work and can be applied to multi band applications.
    Matched MeSH terms: Electromagnetic Phenomena
  10. Islam SS, Faruque MR, Islam MT
    Sci Rep, 2016 09 16;6:33624.
    PMID: 27634456 DOI: 10.1038/srep33624
    A new, metamaterial-based electromagnetic cloaking operation is proposed in this study. The metamaterial exhibits a sharp transmittance in the C-band of the microwave spectrum with negative effective property of permittivity at that frequency. Two metal arms were placed on an FR-4 substrate to construct a double-split-square shape structure. The size of the resonator was maintained to achieve the effective medium property of the metamaterial. Full wave numerical simulation was performed to extract the reflection and transmission coefficients for the unit cell. Later on, a single layer square-shaped cloak was designed using the proposed metamaterial unit cell. The cloak hides a metal cylinder electromagnetically, where the material exhibits epsilon-near-zero (ENZ) property. Cloaking operation was demonstrated adopting the scattering-reduction technique. The measured result was provided to validate the characteristics of the metamaterial and the cloak. Some object size- and shape-based analyses were performed with the cloak, and a common cloaking region was revealed over more than 900 MHz in the C-band for the different objects.
    Matched MeSH terms: Electromagnetic Phenomena
  11. Mohamed Khalaf alla Hassan Mohamed, Raja Syamsul Azmir Raja Abdullah, Rasid, M.F.A.
    MyJurnal
    This paper analyses electromagnetic signal scattered from the target crossing the Forward Scattering
    Radar (FSR) system baseline. The aim of the analysis was to extract the Doppler signal of a target under the influence of high ground clutter and noise interference. The extraction was used for the
    automatic target detection (ATD) in the FSR system. Two extraction methods, namely Hilbert Transform and Wavelet Technique, were analyzed. The detection using the Hilbert Transform is only applicable for some conditions; however, the detection using the Wavelet Technique is more robust to any clutter and noise level. From 55 sets of signal, only 4% of false alarm was detected or occurred when the Wavelet Technique was applied as a detection scheme. Two sets of field experimentation were carried out and the target’s signal under the influence of high clutter had successfully been detected using the proposed method.
    Matched MeSH terms: Electromagnetic Phenomena
  12. Pornsuwancharoen N, Youplao P, Amiri IS, Aziz MS, Tran QL, Ali J, et al.
    Microsc Res Tech, 2018 Aug;81(8):872-877.
    PMID: 29737596 DOI: 10.1002/jemt.23049
    A conventional Michelson interferometer is modified and used to form the various types of interferometers. The basic system consists of a conventional Michelson interferometer with silicon-graphene-gold embedded between layers on the ports. When light from the monochromatic source is input into the system via the input port (silicon waveguide), the change in optical path difference (OPD) of light traveling in the stacked layers introduces the change in the optical phase, which affects to the electron mean free path within the gold layer, induces the change in the overall electron mobility can be seen by the interferometer output visibility. Further plasmonic waves are introduced on the graphene thin film and the electron mobility occurred within the gold layer, in which the light-electron energy conversion in terms of the electron mobility can be observed, the gold layer length is 100 nm. The measurement resolution in terms of the OPD of

    50 nm is achieved. In applications, the outputs of the drop port device of the modified Michelson interferometer can be arranged by the different detectors, where the polarized light outputs, the photon outputs, the electron spin outputs can be obtained by the interference fringe visibility, mobility visibility and the spin up-down splitting output energies. The modified Michelson interferometer theory and the detection schemes are given in details.
    Matched MeSH terms: Electromagnetic Phenomena
  13. Erni Suryani Suharto, Nurul I'zzah Othman, Mohd Agos Salim Nasir
    MyJurnal
    In this paper, we demonstrate a modified scheme for solving the nonlinear KleinGordon
    equation of PDE hyperbolic types. The Klein-Gordon equation is a relativistic
    wave equation version of the Schrodinger equation, which is widely used in quantum
    mechanics. Additionally, the nonstandard finite difference scheme has been used
    extensively to solve differential equations and we have constructed a modified scheme
    based on the nonstandard finite difference scheme associated with harmonic mean
    averaging for solving the nonlinear inhomogeneous Klein-Gordon equation where the
    denominator is replaced by an unusual function. The numerical results obtained have
    been compared and showed to have a good agreement with results attained using the
    standard finite difference (CTCS) procedure, which provided that the proposed scheme
    is reliable. Numerical experiments are tested to validate the accuracy level of the
    scheme with the analytical results.
    Matched MeSH terms: Electromagnetic Phenomena
  14. Islam MT, Samsuzzaman M, Islam MT, Kibria S, Singh MJ
    Sensors (Basel), 2018 Sep 05;18(9).
    PMID: 30189684 DOI: 10.3390/s18092962
    Microwave breast imaging has been reported as having the most potential to become an alternative or additional tool to the existing X-ray mammography technique for detecting breast tumors. Microwave antenna sensor performance plays a significant role in microwave imaging system applications because the image quality is mostly affected by the microwave antenna sensor array properties like the number of antenna sensors in the array and the size of the antenna sensors. In this paper, a new system for successful early detection of a breast tumor using a balanced slotted antipodal Vivaldi Antenna (BSAVA) sensor is presented. The designed antenna sensor has an overall dimension of 0.401λ × 0.401λ × 0.016λ at the first resonant frequency and operates between 3.01 to 11 GHz under 10 dB. The radiating fins are modified by etching three slots on both fins which increases the operating bandwidth, directionality of radiation pattern, gain and efficiency. The antenna sensor performance of both the frequency domain and time domain scenarios and high-fidelity factor with NFD is also investigated. The antenna sensor can send and receive short electromagnetic pulses in the near field with low loss, little distortion and highly directionality. A realistic homogenous breast phantom is fabricated, and a breast phantom measurement system is developed where a two antennas sensor is placed on the breast model rotated by a mechanical scanner. The tumor response was investigated by analyzing the backscattering signals and successful image construction proves that the proposed microwave antenna sensor can be a suitable candidate for a high-resolution microwave breast imaging system.
    Matched MeSH terms: Electromagnetic Phenomena
  15. Khalid Md. Nor, Ithnin Abdul Jalil, Hassan Abu Kasim
    The relativistic Schrodinger equation is reinterpreted as describing a classical particle that mutually-interacts with other objects via electromagnetic-like gravity waves. The accompanying derivation equates the usual quantum mechanical energy and momentum operators to the effects of negative or attractive energy. Lorentz-like transformation equations are obtained that yield the uncertainty principle such that quantum uncertainty is ascribed to the disregard of a magnetic-like component of a gravity wave. Finally, quantum-level Maxwell-like equations that involve the above gravity waves are derived.
    Persamaan Schrodinger kerelatifan ditafsirkan sebagai memperihalkan suatu zarah klasik yang berinteraksi dengan jasad-jasad lain melalui gelombang graviti yang berciri keelektromagnetan. Terbitan sampingan menyamakan pengoperasi-pengeoperasi tenaga dan momentum mekanik kuantum dengan kesan-kesan tenaga negatif atau tarikan. Persamaan-persamaan bermirip transformasi Lorentz diperolehi yang menerbitkan prinsip ketakpastian dan memberi ketakpastian kuantum sebagai kesan pengabaian bahagian gelombang graviti yang bermirip kemagnetan. Akhir sekali, persamaan-persamaan diparas kuntum yang bermirip persamaan-persamaan Maxwell diterbitkan dan melibatkan gelombang graviti yang tersebut di atas.
    Matched MeSH terms: Electromagnetic Phenomena
  16. Abdul Ghapor Hussin, Norli Anida Abdullah, Ibrahim Mohamed
    This paper gives a comprehensive discussion on complex regression model by extending the idea of regression model to circular variables. Various aspect have been considered such as the biasness of parameters, error assumptions and model checking. The advantage of this approach is that it allows the use of usual technique available in ordinary linear regression for the regression of circular variables. The quality of the estimates and the feasibility of the approach were illustrated via simulation. The model was then applied to the wave direction data.
    Matched MeSH terms: Electromagnetic Phenomena
  17. Islam SS, Faruque MRI, Islam MT
    Materials (Basel), 2014 Jul 02;7(7):4994-5011.
    PMID: 28788116 DOI: 10.3390/ma7074994
    This paper presents the design and analysis of a novel split-H-shaped metamaterial unit cell structure that is applicable in a multi-band frequency range and that exhibits negative permeability and permittivity in those frequency bands. In the basic design, the separate split-square resonators are joined by a metal link to form an H-shaped unit structure. Moreover, an analysis and a comparison of the 1 × 1 array and 2 × 2 array structures and the 1 × 1 and 2 × 2 unit cell configurations were performed. All of these configurations demonstrate multi-band operating frequencies (S-band, C-band, X-band and Ku-band) with double-negative characteristics. The equivalent circuit model and measured result for each unit cell are presented to validate the resonant behavior. The commercially available finite-difference time-domain (FDTD)-based simulation software, Computer Simulation Technology (CST) Microwave Studio, was used to obtain the reflection and transmission parameters of each unit cell. This is a novel and promising design in the electromagnetic paradigm for its simplicity, scalability, double-negative characteristics and multi-band operation.
    Matched MeSH terms: Electromagnetic Phenomena
  18. Islam MT, Alam MS
    Materials (Basel), 2013 Jan 07;6(1):143-155.
    PMID: 28809299 DOI: 10.3390/ma6010143
    A compact planar meander-bridge high impedance electromagnetic structure (MBHIES) was designed and its bandgap characteristics, mutual coupling reduction abilities were studied and compared in detail. Several parametric analyses were performed to obtain optimized design values and the transmission responses were calculated through the suspended microstrip line and waveguide simulation methods. The achieved bandgap is 2.3 GHz (2.55-4.85 GHz) with -61 dB minimum transmission coefficient level at the center frequency of 3.6 GHz. To see the effectiveness, the proposed design was inserted between a microstrip patch antenna array which operates at 3.8 GHz and whose operating bandwidth falls within the MBHIES bandgap. The surface wave suppression phenomenon was analyzed and simulated results are verified by measuring the fabricated prototypes, both are in good agreement. The configuration reduced the mutual coupling by 20.69 dB in simulation and 19.18 dB in measurement, without affecting the radiation characteristics of the array but increasing the gain slightly.
    Matched MeSH terms: Electromagnetic Phenomena
  19. Lee HS, Choe HB, Baek IY, Singh JK, Ismail MA
    Materials (Basel), 2017 Oct 04;10(10).
    PMID: 28976931 DOI: 10.3390/ma10101155
    An electromagnetic pulse (EMP) explodes in real-time and causes critical damage within a short period to not only electric devices, but also to national infrastructures. In terms of EMP shielding rooms, metal plate has been used due to its excellent shielding effectiveness (SE). However, it has difficulties in manufacturing, as the fabrication of welded parts of metal plates and the cost of construction are non-economical. The objective of this study is to examine the applicability of the arc thermal metal spraying (ATMS) method as a new EMP shielding method to replace metal plate. The experimental parameters, metal types (Cu, Zn-Al), and coating thickness (100-700 μm) used for the ATMS method were considered. As an experiment, a SE test against an EMP in the range of 103 to 1010 Hz was conducted. Results showed that the ATMS coating with Zn-Al had similar shielding performance in comparison with metal plate. In conclusion, the ATMS method is judged to have a high possibility of actual application as a new EMP shielding material.
    Matched MeSH terms: Electromagnetic Phenomena
  20. Nasir MSM, Ab-Kadir MZA, Radzi MAM, Izadi M, Ahmad NI, Zaini NH
    PLoS One, 2019;14(7):e0219326.
    PMID: 31295278 DOI: 10.1371/journal.pone.0219326
    The Sustainable Energy Development Authority of Malaysia (SEDA) regularly receives complaints about damaged components and distribution boards of PV systems due to lightning strikes. Permanent and momentary interruptions of distribution circuits may also occur from the disturbance. In this paper, a solar PV Rooftop system (3.91 kWp) provided by SEDA was modelled in the PSCAD/EMTDC. The Heidler function was used as a lightning current waveform model to analyse the transient current and voltage at two different points susceptible to the influence of lightning events such as different lightning current wave shape, standard lightning current and non-standard lightning current. This study examines the effect on the system components when lightning directly strikes at two different points of the installation. The two points lie between the inverter and the solar PV array and between inverter and grid. Exceptionally high current and voltage due to the direct lightning strike on a certain point of a PV Rooftop system was also studied. The result of this case study is observed with and without the inclusion of surge protective devices (SPDs). The parameters used were 31 kA of peak current, 10 metres cable length and lightning impulse current wave shape of 8/20μs. The high current and voltage at P1 striking point were 31 kA and 2397 kV, respectively. As for the AC part, the current and voltage values were found to be 5.97 kA and 5392 kV, respectively.Therefore, SPDs with suitable rating provided by SEDA were deployed. Results showed that high transient current voltage is expected to clamp sharply at the values of 1.915 kV and 0 A at the P1 striking point. As for the AC part, the current and voltage values were found to be 0 kA and 0.751 V, respectively. Varying lightning impulse current wave shapes at striking point P2 showed that the highest voltage was obtained at waveshape 10/350 μs at 11277 kV followed by wave shapes of 2/70 μs, 8/20 μs and 0.7/6 μs. The high value of transient voltage was clamped at a lower level of 2.029 kV. Different lightning amplitudes were also applied, ranging from 2-200 kA selected based on the CIGRE distribution. It showed that the current and voltage at P1 and P2 were directly proportional. Therefore, the SPD will be designed at an acceptable rating and proper position of SPD installation at solar PV Rooftop will be proposed. The results obtained in this study can then be utilised to appropriately assign a SPD to protect the PV systems that are connected to the grid. Installing SPDs without considering the needs of lightning protection zones would expose the expensive equipment to potential damage even though the proper energy coordination of SPDs is in place. As such, the simulation results provide a basis for controlling the impacts of direct lightning strikes on electrical equipment and power grids and thus justify SPD coordination to ensure the reliability of the system.
    Matched MeSH terms: Electromagnetic Phenomena*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links