Displaying publications 1 - 20 of 643 in total

Abstract:
Sort:
  1. Palaniandy, Samayamutthirian, Khairun Azizi Mohd Azizli, Hashim Hussin, Syed Fuad Saiyid Hashim
    MyJurnal
    Mechanical activation of quartz was carried out in jet mill at various specific kinetic energy level and classifier speed. The characterization of the particle size, crystallite size, amorphism rate and lattice strain was conducted on the feed and mechanically activated particles. The area under the prominent quartz peak was used to calculate the amorphism rate of the mechanically activated particles. Scherer equation was used to determine the crystallite size of the feed and mechanically activated particles. Mean particle size less than 5μm was obtained when the specific kinetic energy is ranging between 500 kWh/ton and 1000 kWh/ton. Amorphism of the mechanically activated particles up to 18% was observed at 500 kWh/ton. The crystallite size and lattice strain is influence by the intensity of the specific kinetic energy and classifier speed. The reduction in the crystallite size up to 39% was observed where the minimum crystallite is 23nm. The lattice strain is ranging from 0.024 to 0.038 respective to the specific kinetic energy and classifier speed.
    Matched MeSH terms: Particle Size
  2. Liang J, Abdullah ALB, Li Y, Wang H, Xiong S, Han M
    Sci Total Environ, 2024 Dec 01;954:176530.
    PMID: 39332714 DOI: 10.1016/j.scitotenv.2024.176530
    With the widespread use of plastic products, microplastics and nanoplastics have emerged as prevalent pollutants in coastal aquatic ecosystems. Parasesarma pictum, a common estuarine crab species, was selected as a model organism. P. pictum was exposed to polystyrene (PS) particles of sizes 80 nm (80PS), 500 nm (500PS), and 1000 nm (1000PS), as well as to clean seawater (CK) for 21 days. Histological and fluorescent staining results showed that PS particles of all three sizes induced hepatopancreatic nuclear pyknosis, cell junction damage, and necrosis. The degree of damage was observed as 1000PS > 80PS > 500PS. Transcriptomic analysis revealed that major differentially expressed genes (DEGs) were associated with cellular processes, membrane components, and catalytic activity. The respiratory chain disruptions and immune exhaustion induced by 1000PS were notably stronger than those by 80PS and 500PS. Additionally, necrosis caused hepatopancreas injury in P. pictum rather than apoptosis or autophagy after long-term PS particle exposure. Furthermore, PS particles of all three sizes inhibited innate immunity, while the complement pathway was not significantly affected in the 80PS group. This study elucidated potential distinctions in how plastic particles of varying sizes (nanoplastics, microplastics, and micro/nanoplastics) impact P. pictum, providing a reference for toxicological mechanism research on microplastics and nanoplastics in aquatic organisms. Future research should focus on exploring long-term effects and potential mitigation strategies for microplastics and nanoplastics of more types and a wider range of particle size pollution in aquatic environments.
    Matched MeSH terms: Particle Size*
  3. Irzaman, Jamal, Z., Idris, M.S., Kurnia, D., Barmawi, M.
    MyJurnal
    The specimens used were CaCO3 (Sigma Aldrich, purity 99.9 %). We have 23 parameters and 20 iterations, including two theta zero error, scale factor, thermal effect, coefficients for polynomial describing the background; U, V, W and mixing parameters of the profile peak function, lattice constants, positional parameters and overall isotropic temperature factors. Most the samples show that the crystal structure are rhombohedral with lattice constants a = b = 4.981 Å, c = 17.044 Å and space group is R3C. The microstrain (K) and the particle size (V) of CaCO3 ceramic were calculated using 10 the full width at half maximum (FWHM) of diffraction peaks from (0 1 2), (1 0 4), (0 0 6), (1 1 0), (1 1 3), (2 0 2), (0 1 8), (1 1 6), (2 2 1 ), (1 2 2) crystal planes are 2.1 x 10-2 and
    362 nm, respectively.
    Matched MeSH terms: Particle Size
  4. Alfatama M, Shahzad Y, Choukaife H
    Adv Colloid Interface Sci, 2024 Mar;325:103098.
    PMID: 38335660 DOI: 10.1016/j.cis.2024.103098
    The electrospray (ES) technique has proven to be an effective and a versatile approach for crafting drug delivery carriers with diverse dimensions, multiple layers, and varying morphologies. Achieving the desired particle properties necessitates careful optimization of various experimental parameters. This review delves into the most prevalent ES system configurations employed for this purpose, such as monoaxial, coaxial, triaxial, and multi-needle setups with solid or liquid collector. In addition, this work underscores the significance of ES in drug delivery carriers and its remarkable ability to encapsulate a wide spectrum of therapeutic agents, including drugs, nucleic acids, proteins, genes and cells. Depth examination of the critical parameters governing the ES process, including the choice of polymer, surface tension, voltage settings, needle size, flow rate, collector types, and the collector distance was conducted with highlighting on their implications on particle characteristics, encompassing morphology, size distribution, and drug encapsulation efficiency. These insights illuminate ES's adaptability in customizing drug delivery systems. To conclude, this review discusses ES process optimization strategies, advantages, limitations and future directions, providing valuable guidance for researchers and practitioners navigating the dynamic landscape of modern drug delivery systems.
    Matched MeSH terms: Particle Size
  5. Sivadasan D, Venkatesan K, Mohamed JMM, Alqahtani S, Asiri YI, Faisal MM, et al.
    Sci Rep, 2024 Mar 16;14(1):6361.
    PMID: 38493177 DOI: 10.1038/s41598-024-55953-2
    Loratadine (LoR) is a highly lipophilic and practically insoluble in water, hence having a low oral bioavailability. As it is formulated as topical gel, it competitively binds with the receptors, thus reducing the side-effects. The objective of this study was to prepare LoR loaded nanosponge (LoR-NS) in gel for topical delivery. Nine different formulations of emulsion were prepared by solvent evaporation method with polyvinyl alcohol (PVA), ethyl cellulose (EC), and dichloromethane (DCM). Based on 32 Full Factorial Design (FFD), optimization was carried out by varying the concentration of LOR:EC ratio and stirring rate. The preparations were subjected for the evaluation of particle size (PS), in vitro release, zeta potential (ZP) and entrapment efficiency (EE). The results revealed that the NS dispersion was nanosized with sustained release profiles and significant PS. The optimised formulation was formulated and incorporated into carbopol 934P hydrogel. The formulation was then examined to surface morphological characterizations using scanning electron microscopy (SEM) which depicted spherical NS. Stability studies, undertaken for 2 months at 40 ± 2 °C/75 ± 5% RH, concluded to the stability of the formulation. The formulation did not cause skin irritation. Therefore, the prepared NS hydrogel proved to be a promising applicant for LoR as a novel drug delivery system (NDDS) for safe, sustained and controlled topical application.
    Matched MeSH terms: Particle Size
  6. Wong SK, Supramaniam J, Wong TW, Soottitantawat A, Ruktanonchai UR, Tey BT, et al.
    Carbohydr Res, 2021 Jun;504:108336.
    PMID: 33964507 DOI: 10.1016/j.carres.2021.108336
    The development of hybrid polysaccharide-protein complexes as Pickering emulsion stabilizers has attracted increasing research interest in recent years. This work presents an eco-friendly surface modification strategy to functionalize hydrophilic cellulose nanocrystals (CNC) using hydrophobic soy protein isolate (SPI) via mussel adhesive-inspired poly (l-dopa) (PLD) to develop improved nanoconjugates as stabilizers for oil-in-water Pickering emulsion. The physicochemical properties of the CNC-PLD-SPI nanoconjugate were evaluated by solid-state 13C NMR, FT-IR, TGA, XRD, contact angle analysis, and TEM. The modified CNC (conjugation content of 38.22 ± 1.21%) had lowered crystallinity index, higher thermal stability, and more hydrophobic than unmodified CNC, with an average particle size of 309.9 ± 8.0 nm. Use of amphiphilic CNC-PLD-SPI nanoconjugate with greater conformational flexibility as Pickering stabilizer produced oil-in-water emulsions with greater physical stability.
    Matched MeSH terms: Particle Size
  7. Dahalan FA, Abdullah N, Yuzir A, Olsson G, Salmiati, Hamdzah M, et al.
    Bioresour Technol, 2015 Apr;181:291-6.
    PMID: 25661308 DOI: 10.1016/j.biortech.2015.01.062
    Aerobic granulation is increasingly used in wastewater treatment due to its unique physical properties and microbial functionalities. Granule size defines the physical properties of granules based on biomass accumulation. This study aims to determine the profile of size development under two physicochemical conditions. Two identical bioreactors namely Rnp and Rp were operated under non-phototrophic and phototrophic conditions, respectively. An illustrative scheme was developed to comprehend the mechanism of size development that delineates the granular size throughout the granulation. Observations on granules' size variation have shown that activated sludge revolutionised into the form of aerobic granules through the increase of biomass concentration in bioreactors which also determined the changes of granule size. Both reactors demonstrated that size transformed in a similar trend when tested with and without illumination. Thus, different types of aerobic granules may increase in size in the same way as recommended in the aerobic granule size development scheme.
    Matched MeSH terms: Particle Size*
  8. Mohamad N, Ubaidillah, Mazlan SA, Choi SB, Abdul Aziz SA, Sugimoto M
    Int J Mol Sci, 2019 Mar 27;20(7).
    PMID: 30934679 DOI: 10.3390/ijms20071525
    The transient response of magnetorheological (MR) materials, in general, is very important for design consideration in MR-based devices. Better response to magnetic fields is beneficial for a better response rate to the electrical current applied in the electromagnetic coil. As a result, MR-based devices would have a high response to external stimuli. In this work, the principal characteristics of magnetorheological greases (MRGs) which have two different particle shapes are experimentally investigated. One type of particle distributed in the grease medium is conventional spherical-shaped carbonyl iron (CI) particles, while the other is plate-like CI particles made using a high-energy rotary ball mill from spherical CI particles. A set of bidisperse MRG samples are firstly prepared by adjusting the weight percentage of the plate-like CI particles and mixing with the spherical CI particles. Subsequently, three important properties of MRGs in terms of their practical application are measured and compared between the two different particle shapes. The field-dependent apparent viscoelastic properties of the prepared MRG samples are measured, followed by the field-dependent storage and loss moduli using an oscillatory shear rheometer. In addition, the transient response time, which indicates the speed in the actuating period of MRGs, is measured by changing the strain amplitude. Then, a comparative assessment on the three properties are undertaken between two different particle shapes by presenting the corresponding results in the same plot. It is shown that the bidisperse MRG with plate-like CI particles exhibits an increase in the initial apparent viscosity as well as stiffness property compared to the MRG with spherical particles only.
    Matched MeSH terms: Particle Size*
  9. Singh A, Himanshu M, Verma B, Syed A, Elgorban AM, Wong LS, et al.
    Luminescence, 2024 Sep;39(9):e4884.
    PMID: 39258707 DOI: 10.1002/bio.4884
    In present work, synthesis of a nanohybrid material using Fe and MoS2 has been performed via a cost-effective and environmentally friendly route for sustainable manufacturing innovation. Rice straw extract was prepared and used as a reducing and chelating agent to synthesize the nanohybrid material by mixing it with molybdenum disulfide (MoS2) and ferric nitrate [Fe (NO3)3.9H2O], followed by heating and calcination. The X-ray diffraction (XRD) pattern confirms the formation of a nanohybrid consisting of monoclinic Fe2(MoO4)3, cubic Fe2.957O4, and orthorhombic FeS with 86% consisting of Fe2(MoO4)3. The properties were analyzed through Fourier-transformed infrared spectroscopy (FTIR), atomic force microscopy (AFM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The results of the dynamic light scattering (DLS) study revealed a heterogeneous size distribution, with an average particle size of 48.42 nm for 18% of particles and 384.54 nm for 82% of particles. Additionally, the zeta potential was measured to be -18.88 mV, suggesting moderate stability. X-ray photoelectron spectroscopy (XPS) results confirmed the presence of both Fe2+ and Fe3+ oxidation states along with the presence of Molybdenum (Mo), oxygen (O), and Sulphur (S). The prepared nanohybrid material exhibited a band gap of 2.95 eV, and the photoluminescence intensity increased almost twice that of bare MoS2. The present work holds potential applications in photo luminescent nanoplatform for biomedical applications.
    Matched MeSH terms: Particle Size*
  10. Xu LL, Zhang HF, Li M, Ng SW, Feng JH, Mao JG, et al.
    J Am Chem Soc, 2018 09 19;140(37):11569-11572.
    PMID: 30141923 DOI: 10.1021/jacs.8b06725
    Chiroptical activity is observed from an achiral adenine-containing metal-organic framework (MOF) named ZnFDCA. Such a seemingly counterintuitive phenomenon can, in fact, be predicted by the intrinsic crystal symmetry of 4̅2 m point group. Although theoretically allowed, examples of optically active achiral crystals are extremely rare. ZnFDCA is the first reported achiral MOF showing optical activity, as demonstrated by a pair of circular dichroism signals with opposite signs and enhanced intensity. Moreover, simply through adding an amino substituent to adenine, the chiroptical activity, as well as nonlinear optical activity, of the analogous MOF, namely ZnFDCA-NH2, disappears due to diverse packing pattern giving rise to centrosymmetric crystal symmetry.
    Matched MeSH terms: Particle Size
  11. Ng SK, Nyam KL, Nehdi IA, Chong GH, Lai OM, Tan CP
    Food Sci Biotechnol, 2016;25(Suppl 1):15-21.
    PMID: 30263481 DOI: 10.1007/s10068-016-0093-8
    β-Lactoglobulin (β-lg) can produce fibrils that have multi-functional properties. Impacts of different stirring speeds on characteristics of β-lg fibrils as a stable form in β-lg fibril solutions were investigated. Fibril concentration, fibril morphology, turbidity, particle size distribution, zeta potential, and rheological behavior of solutions were studied. Stirring enhanced fibril formation and stability of a fibril solution, in comparison with unstirred solutions. Increasing the stirring speed produced more turbidity and a greater distribution of particle sizes, higher viscosity values, but no differences in zeta potential values of β-lg fibril solutions. However, a high stirring speed is not feasible due to reduction of the fibril yield and changes in fibril morphology.
    Matched MeSH terms: Particle Size
  12. Majid AMA, Rahiman MHF, Wong TW
    Int J Pharm, 2021 Aug 10;605:120786.
    PMID: 34111546 DOI: 10.1016/j.ijpharm.2021.120786
    This study developed a tester where the powder flow was characterized using a low sample mass (2 g) and impact instead of dispersion mechanism to mitigate test space constraint. An impact chamber was established where the test powder bed of seven lactose grades was weight-impacted to produce impact crater and ejecta, and imaged quantitatively to determine crater profiling signature (crater depth), regional topography (ejecta roughness), Otsu threshold (bed continuity) and edge segmentation (bed deformation). The Hausner ratio (HR) and Carr's index (CI) values of lactose, and their powder dispersion distance and surface area characteristics evaluated by gas-pressurized dispersibility test were examined as reference method. The crater signature profiling and regional topography were correlated to HR, CI, dispersive distance and surface area. A poorer powder flow was characterized by higher values of crater signature profiling, regional topography, HR, CI, and lower dispersive distance and surface area. The crater signature profiling and regional topography values were higher with smaller and rougher lactose particles that were cohesive. The powder impact flow is a viable non-dispersive approach to characterize powder flowability using a small sample mass and test space.
    Matched MeSH terms: Particle Size
  13. Chen WH, Chang CM, Mutuku JK, Lam SS, Lee WJ
    J Hazard Mater, 2021 08 15;416:125856.
    PMID: 34492805 DOI: 10.1016/j.jhazmat.2021.125856
    Inhalation of aerosols such as pharmaceutical aerosols or virus aerosol uptake is of great concern to the human population. To elucidate the underlying aerosol dynamics, the deposition fractions (DFs) of aerosols in healthy and asthmatic human airways of generations 13-15 are predicted. The Navier-stokes equations governing the gaseous phase and the discrete phase model for particles' motion are solved using numerical methods. The main forces responsible for deposition are inertial impaction forces and complex secondary flow velocities. The curvatures and sinusoidal folds in the asthmatic geometry lead to the formation of complex secondary flows and hence higher DFs. The intensities of complex secondary flows are strongest at the generations affected by asthma. The DF in the healthy airways is 0%, and it ranges from 1.69% to 52.93% in the asthmatic ones. From this study, the effects of the pharmaceutical aerosol particle diameters in the treatment of asthma patients can be established, which is conducive to inhibiting the inflammation of asthma airways. Furthermore, with the recent development of COVID-19 which causes pneumonia, the predicted physics and effective simulation methods of bioaerosols delivery to asthma patients are vital to prevent the exacerbation of the chronic ailment and the epidemic.
    Matched MeSH terms: Particle Size
  14. Karami A, Golieskardi A, Keong Choo C, Larat V, Galloway TS, Salamatinia B
    Sci Rep, 2017 04 06;7:46173.
    PMID: 28383020 DOI: 10.1038/srep46173
    The occurrence of microplastics (MPs) in saltwater bodies is relatively well studied, but nothing is known about their presence in most of the commercial salts that are widely consumed by humans across the globe. Here, we extracted MP-like particles larger than 149 μm from 17 salt brands originating from 8 different countries followed by the identification of their polymer composition using micro-Raman spectroscopy. Microplastics were absent in one brand while others contained between 1 to 10 MPs/Kg of salt. Out of the 72 extracted particles, 41.6% were plastic polymers, 23.6% were pigments, 5.50% were amorphous carbon, and 29.1% remained unidentified. The particle size (mean ± SD) was 515 ± 171 μm. The most common plastic polymers were polypropylene (40.0%) and polyethylene (33.3%). Fragments were the primary form of MPs (63.8%) followed by filaments (25.6%) and films (10.6%). According to our results, the low level of anthropogenic particles intake from the salts (maximum 37 particles per individual per annum) warrants negligible health impacts. However, to better understand the health risks associated with salt consumption, further development in extraction protocols are needed to isolate anthropogenic particles smaller than 149 μm.
    Matched MeSH terms: Particle Size
  15. Wang G, Pu X
    Sains Malaysiana, 2014;43:807-812.
    A distinct element approach has been introduced for simulating the plugging performance of granular lost circulation materials (LCM) in a fracture. This approach solves the fully coupled fracture walls, fluid and particles system in an interactive environment. The effects of the particle shape, size distribution and concentration on the fracture-plugging performance of the granular LCM have been investigated using the three-dimensional particle flow code (PFC3D). The simulated results showed that the irregular granular LCM could plug a fracture width larger than the sieving granulation by single-particle bridging type. The particle size distribution (PSD) of LCM dominates the plugging depth and efficiency in a fracture and there exists an optimum concentration for maximum effect of LCM additives.
    Matched MeSH terms: Particle Size
  16. Rashid M, Huda N, Norelyza H, Hasyimah N
    Sains Malaysiana, 2015;44:565-569.
    A new type of cyclone design configuration called MR-deDuster, which contains multi cyclone, has been developed.
    A theoretical study had been carried out to evaluate and predict the performance of a MR-deDuster. In this paper, a
    comparative study was done to investigate the performance of MR-deDuster with other conventional cyclones in terms
    of collection efficiency and pressure drop. The performance of MR-deDuster was measured by its collection efficiency
    based on the particle size distribution of activated carbon. It was found that MR-deDuster is able to collect as high as
    94% of PM10 which is high comparing with many other conventional cyclones. In addition, the pressure drop of the unit
    is relatively low compared to the other cyclones which highlight the ability of the unit to capture the fine particle at low
    pressure drop.
    Matched MeSH terms: Particle Size
  17. Yusrabbil Amiyati Yusof, Zafarizal Aldrin Azizul Hasan, Azhar Ariffin
    Sains Malaysiana, 2018;47:511-515.
    This paper reports the effects of glyceryl ether specifically mono-tert-butoxypropanediol on oil in water emulsion system.
    Based on 12 HLB value, screening for stable emulsions was carried out without the presence of glyceryl ether. A stable
    emulsion was used as a control. Then the effects of glyceryl ether on the emulsion system were investigated. The emulsions
    prepared were analyzed for stability, viscosity, pH value, particle size, in vitro dermal irritation potential, in vitro ocular
    irritation potential and also moisturizing property. The incorporation of glycerol in the emulsion system was also done
    for comparison. Emulsions with glyceryl ether showed lower viscosity values than emulsions with glycerol. Furthermore,
    the emulsions also exhibited moisturizing property compared to the control emulsion. Glyceryl ether is suitable to be
    used in cosmetic products which require reduced viscosity but retain its skin hydration property.
    Matched MeSH terms: Particle Size
  18. Goh KB, Li Z, Chen X, Liu Q, Wu T
    J Colloid Interface Sci, 2022 Feb 15;608(Pt 2):1999-2008.
    PMID: 34749148 DOI: 10.1016/j.jcis.2021.10.092
    HYPOTHESIS: The performance of a polymeric core-shell microreactor depends critically on (i) mass transfer, (ii) catalyzed chemical reaction, and (iii) deactivation within the nonuniform core-shell microstructure environment. As such, these three basic working principles control the active catalytic phase density in the reactor.

    THEORY: We present a high-fidelity, image-based nonequilibrium computational model to quantify and visualize the mass transport as well as the deactivation process of a core-shell polymeric microreactor. In stark contrast with other published works, our microstructure-based computer simulation can provide a single-particle visualization with a micrometer spatial accuracy.

    FINDINGS: We show how the interplay of kinetics and thermodynamics controls the product-induced deactivation process. The model predicts and visualizes the non-trivial, spatially resolved active catalyst phase patterns within a core-shell system. Moreover, we also show how the microstructure influences the formation of foulant within a core-shell structure; that is, begins from the core and grows radially onto the shell section. Our results suggest that the deactivation process is highly governed by the porosity/microstructure of the microreactor as well as the affinity of the products towards the solid phase of the reactor.

    Matched MeSH terms: Particle Size
  19. Nine MJ, Choudhury D, Hee AC, Mootanah R, Osman NAA
    Materials (Basel), 2014 Feb 10;7(2):980-1016.
    PMID: 28788496 DOI: 10.3390/ma7020980
    Wear debris, of deferent sizes, shapes and quantities, generated in artificial hip and knees is largely confined to the bone and joint interface. This debris interacts with periprosthetic tissue and may cause aseptic loosening. The purpose of this review is to summarize and collate findings of the recent demonstrations on debris characterization and their biological response that influences the occurrence in implant migration. A systematic review of peer-reviewed literature is performed, based on inclusion and exclusion criteria addressing mainly debris isolation, characterization, and biologic responses. Results show that debris characterization largely depends on their appropriate and accurate isolation protocol. The particles are found to be non-uniform in size and non-homogeneously distributed into the periprosthetic tissues. In addition, the sizes, shapes, and volumes of the particles are influenced by the types of joints, bearing geometry, material combination, and lubricant. Phagocytosis of wear debris is size dependent; high doses of submicron-sized particles induce significant level of secretion of bone resorbing factors. However, articles on wear debris from engineered surfaces (patterned and coated) are lacking. The findings suggest considering debris morphology as an important parameter to evaluate joint simulator and newly developed implant materials.
    Matched MeSH terms: Particle Size
  20. Putra NR, Rizkiyah DN, Aziz AHA, Mamat H, Jusoh WMSW, Idham Z, et al.
    Sci Rep, 2023 Jul 05;13(1):10871.
    PMID: 37407592 DOI: 10.1038/s41598-023-32181-8
    The purpose of this work was to establish the best particle size for recovering high yields of total phenolic compounds (TPC), total anthocyanin compounds(TAC) and total flavonoid compounds (TFC) from roselle (Hibiscus sabdariffa) by applying supercritical carbon dioxide (ScCO2). The extraction rate, diffusivity and solubility of yield in ScCO2 were also studied and calculated utilizing models. Pressure (10 and 30 MPa), temperature (40 and 60 °C), and particle size (250 µm size of 250 µm size of roselle provides the maximum bioactive compound recovery and solubility. Furthermore, the diffusivity and extraction of ScCO2 are increased by decreasing the particle size. Therefore, a smaller particle size is appropriate for roselle extraction by ScCO2 based on the experimental and modelling data.
    Matched MeSH terms: Particle Size
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links