Displaying publications 1 - 20 of 38 in total

Abstract:
Sort:
  1. Lim JJ, Salowi MA, Adnan TH, Anuar NA, Ngah NF, Choo MM
    Med J Malaysia, 2021 03;76(2):190-198.
    PMID: 33742627
    INTRODUCTION: The aim of this study was to compare the visual outcomes of phacoemulsification with intraocular lens implantation (IOL) surgery in patients with and without diabetes mellitus (DM) in Malaysia over a 12-year period and to identify factors that may contribute to poor visual outcome.

    MATERIALS AND METHODS: Data was retrieved from the webbased Malaysian Cataract Surgery Registry (CSR). Perioperative data for cataract surgery performed from 2007- 2018 were analysed. Inclusion criteria were age ≥40 years, phacoemulsification and IOL and senile cataract. Combined surgeries, surgeries performed by trainees and ocular comorbidities were excluded. Post-operative Best-Corrected Visual Acuity (BCVA) were compared. Factors affecting poor visual outcomes among those with DM were analysed using multivariate logistic regression to produce adjusted odds ratio (OR) for variables of interest.

    RESULTS: Total number of cases between 2007-2018 was 442,858, of whom 179,210 qualified for our analysis. DM group consisted of 72,087 cases (40.2%). There were 94.5% cases in DM group and 95.0Ź from non-DM group who achieved BCVA ≥6/12 (p<0.001). Among patients with DM, advanced age (70-79 years old, OR: 2.54, 95% Confidence Interva, 95%CI: 1.91, 3.40; 80-89 years old, OR: 5.50, 95%CI: 4.02, 7.51), ≥90 years, OR: 9.77, 95%CI: 4.18, 22.81), poor preoperative presenting visual acuity [<6/18-6/60] (OR: 2.40, 95%CI: 1.84, 3.14) and <6/60-3/60 (OR: 3.00, 95%CI: 2.24, 4.02), <3/60 (OR 3.63, 95%CI: 2.77, 4.74)], presence of intraoperative complication (OR 2.24, 95%CI: 1.86, 2.71) and presence of postoperative complication (OR 5.21, 95%CI: 2.97, 9.16) were significant factors for poor visual outcome.

    CONCLUSIONS: Visual outcomes following phacoemulsification with IOL implantation surgery among cases with DM were poorer compared to cases without DM. Risk factors for poor visual outcomes among cases with DM were identified.

    Matched MeSH terms: Lens, Crystalline
  2. Shanisha Rubiny A/P Vardi Veloo, Subhadeep Das
    MyJurnal
    Diabetes mellitus is a condition of increase glucose concentration in blood plasma. Complication of diabetes mellitus are progressive and leads to several changes on ocular surface. Lack of data focusing on changes in ocular surface among early detect diabetes. Therefore, the aim of the study is to focus on the prevalence of changes in Meibomian glands, tear films and crystalline lens among early detect diabetes type 2. A descriptive cross sectional study was conducted to assess the grading of Meibomian glands, number of expressible glands, Tear-break up time (TBUT), schirmer’s test I , and crystalline lens in 100 eyes of 50 patients who has type 2 diabetes less than 5 years. Demographic information , medical and ocular history was recorded. Data was entered on SPSS version 25- descriptive analysis. The mean ± standard deviation for age was 51.08 ± 8.708 and the years of diabetes was 3.14 ± 1.498. The results stated, more people has MGD grade 1 with percentage of 39% . Besides, TBUT test has mean ± SD of 4.74 ± 1.404 and tear production with mean of 15.1± 8.650. There were 54% more patients has no changes on crystalline lens. Approximately, high prevalence in changes of Meibomian gland, and tear film while low prevalence on changes of crystalline lens among shorter duration diabetic patients.
    Matched MeSH terms: Lens, Crystalline
  3. Kaur S, Norlaila Mat Daud, Chung KM, Azrin E. Ariffin, Boo N, Ong LC
    A cross-sectional study was undertaken to determine the refractive and biometric status of premature children without Retinopathy of Prematurity (ROP) and full term children. Fifty eight children between the ages of 3 and 7 years (32 children born premature without ROP and another 26 children born full term and normal) were examined. Refractive error, corneal curvature, axial length, anterior chamber depth and crystalline lens thickness were determined. The results revealed that children between the age of 3 and 7 years were emmetropic, irrespective of whether they were born premature without ROP or full term. However, children born premature without ROP had significantly steeper corneas (t = 3.14, p = 0.0349), shorter axial lengths (t = 3.18, p = 0.0313) and thicker crystalline lens (t = 3.31, p = 0.0256) compared to children born full term within the same age group. This study suggests that compensation in ocular parameters can occur to maintain emmetropia, mainly by adjustment of axial length and corneal curvature.
    Matched MeSH terms: Lens, Crystalline
  4. Abdul Nasir NA, Agarwal R, Sheikh Abdul Kadir SH, Vasudevan S, Tripathy M, Iezhitsa I, et al.
    PLoS One, 2017;12(3):e0174542.
    PMID: 28350848 DOI: 10.1371/journal.pone.0174542
    Cataract, a leading cause of blindness, is of special concern in diabetics as it occurs at earlier onset. Polyol accumulation and increased oxidative-nitrosative stress in cataractogenesis are associated with NFκB activation, iNOS expression, ATP depletion, loss of ATPase functions, calpain activation and proteolysis of soluble to insoluble proteins. Tocotrienol was previously shown to reduce lens oxidative stress and inhibit cataractogenesis in galactose-fed rats. In current study, we investigated anticataract effects of topical tocotrienol and possible mechanisms involved in streptozotocin-induced diabetic rats. Diabetes was induced in Sprague Dawley rats by intraperitoneal injection of streptozotocin. Diabetic rats were treated with vehicle (DV) or tocotrienol (DT). A third group consists of normal, non-diabetic rats were treated with vehicle (NV). All treatments were given topically, bilaterally, twice daily for 8 weeks with weekly slit lamp monitoring. Subsequently, rats were euthanized and lenses were subjected to estimation of polyol accumulation, oxidative-nitrosative stress, NFκB activation, iNOS expression, ATP levels, ATPase activities, calpain activity and total protein levels. Cataract progression was delayed from the fifth week onwards in DT with lower mean of cataract stages compared to DV group (p<0.01) despite persistent hyperglycemia. Reduced cataractogenesis in DT group was accompanied with lower aldose reductase activity and sorbitol level compared to DV group (p<0.01). DT group also showed reduced NFκB activation, lower iNOS expression and reduced oxidative-nitrosative stress compared to DV group. Lenticular ATP and ATPase and calpain 2 activities in DT group were restored to normal. Consequently, soluble to insoluble protein ratio in DT group was higher compared to DV (p<0.05). In conclusion, preventive effect of topical tocotrienol on development of cataract in STZ-induced diabetic rats could be attributed to reduced lens aldose reductase activity, polyol levels and oxidative-nitrosative stress. These effects of tocotrienol invlove reduced NFκB activation, lower iNOS expression, restoration of ATP level, ATPase activities, calpain activity and lens protein levels.
    Matched MeSH terms: Lens, Crystalline/drug effects*; Lens, Crystalline/metabolism; Lens, Crystalline/pathology
  5. Safari MJ, Wong JH, Kadir KA, Thorpe NK, Cutajar DL, Petasecca M, et al.
    Eur Radiol, 2016 Jan;26(1):79-86.
    PMID: 26002131 DOI: 10.1007/s00330-015-3818-9
    OBJECTIVES: To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures.

    METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures.

    RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions.

    CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose.

    KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.

    Matched MeSH terms: Lens, Crystalline/radiation effects*
  6. Nurulain MZ, Ahmad S, Asma H, Abdul M
    Med J Malaysia, 2018 04;73(2):67-72.
    PMID: 29703868
    OBJECTIVE: Cataract is the leading cause of blindness in Malaysia. There is an alarming backlog of cataract extraction surgery as the majority believes they did not require surgery. This study aimed to explore the barriers at the primary care level to cataract surgery from the perspective of patients with severe cataract blindness.

    METHODS: Eleven participants were involved in this qualitative research which utilised the interpretative phenomenological analysis approach more renowned in health psychology research. All interviews conducted at their home. The interviews were recorded, typed verbatim, and the transcripts were analysed using NVivo software version 8.0.

    RESULTS: The main barriers identified at the primary care level were 1) nondisclosure of their visual problems originated from their belated needs for better sight, delayed awareness of their visual status and social stigma and 2) patient-provider-related issues namely miscommunication and delayed referral. The first main theme explains their belief for not requiring surgery. This has led to their delayed awareness and impeded disclosure of their visual problems to family members or primary care providers. The second main theme reflects the provider-patient-related issues which retarded cataract detection and referral process required for earlier cataract extraction surgery.

    CONCLUSION: Thus, the appropriate approach targeting these specific barriers at primary care level will be able to detect, motivate and assist patients for early uptake of cataract extraction surgery to improve their vision and prevent severe blindness.

    Matched MeSH terms: Lens, Crystalline
  7. Wai YZ, Chong YY, Lim LT, Chan JB, Chandrasekaran S
    BMC Res Notes, 2023 Jun 22;16(1):116.
    PMID: 37349840 DOI: 10.1186/s13104-023-06391-2
    BACKGROUND: To describe the preferred cataract surgery practices among Malaysian ophthalmologists and medical officers in comparison with the recommended practices.

    METHODS: An online questionnaire was sent out in April 2021, to Malaysian Ophthalmologists and medical officers who perform cataract surgeries. The questions were focused on the preferred cataract surgery practices of the participants. All data obtained were collected, tabulated and analysed.

    RESULTS: A total of 173 participants responded to the online questionnaire. 55% of the participants were within 31-40 years of age. 56.1% preferred peristaltic pump over venturi system. 91.3% of participants practised povidone iodine instillation to the conjunctival sac. With regards to the main wound incision, more than half of the surgeons (50.3%) preferred fixed superior incision and 72.3% of them preferred 2.75 mm microkeratome blade. Most of the participants (63%) were inclined towards C-Loop clear intraocular lens (IOL) with a single-handed push preloaded system. 78.6% of the surgeons routinely use carbachol in their cataract surgery.

    CONCLUSIONS: This survey provides some insight into the current practices among Malaysian ophthalmologists. Most of the practices are in line with international guidelines for preventing postoperative endophthalmitis. This article could help trainees and ophthalmologists benchmark and observe the common cataract surgery practices among their seniors and peers in Malaysia.

    Matched MeSH terms: Lens, Crystalline*
  8. Thevi T, Godinho MA
    Int J Ophthalmol, 2017;10(9):1452-1459.
    PMID: 28944207 DOI: 10.18240/ijo.2017.09.19
    AIM: To explore the associations between various characteristics of Malaysian cataract patients and their management, and their post-operative visual outcomes, to inform relevant bodies to reduce cataract-related blindness.

    METHODS: We conducted a descriptive secondary data analysis of cataract surgery patients in Melaka Hospital, from 2007 to 2014 using the National Eye Database (NED). Patient-related factors (demographic features, systemic and ocular comorbidities) and management-related factors (surgical duration, type of surgery, type of lens) were analysed for their association with visual outcome (acuity).

    RESULTS: Most patients were Malays (48.23%) and Chinese (38.55%) aged 60-79y (range 0-100y). Hypertension (58.61%) and diabetes (44.89%) were major systemic comorbidities. Glaucoma (6.71%) and diabetic retinopathy (10.12%) were the main ocular comorbidities. Other comorbidities were age-related macular degeneration, pterygium, corneal opacities, macula diseases, vitreous haemorrhage, retinal detachment and pseudoexfoliation (0.70%-1.60%). Preoperatively 7150 (55.03%) eyes presented with poor vision. Uncomplicated phacoemulsification performed quickly with foldable lenses gave good results.

    CONCLUSION: Primary care physicians should initiate early detection to prevent late presentation of cataracts causing poor vision and should discuss the risks and benefits of cataract surgery while emphasizing the role of pre-existing comorbidities which may affect the visual outcomes. For good results, phacoemulsification should be done within 30min, without complications, using foldable posterior chamber intraocular lens.
    Matched MeSH terms: Lens, Crystalline
  9. Thevi T, Zin MM
    International Eye Science, 2016;16:600-606.
    AIM: To see the causative factors, associations and outcomes of posterior capsule rupture (PCR). METHODS: A retrospective cohort study was done of all patients with PCR from 2007 to 2014 in Melaka Hospital. Associations between ocular comorbidities, lens related complications, surgeon grade, type of cataract surgery, whether done alone or in combination, with the occurrences of PCR were studied. The final visual outcome of cases with PCR was studied. RESULTS: PCR was the commonest intraoperative complication (n=623, 4.8%) among 12 846 patients. Ocular comorbidities and status of the lens did not cause PCR. Experience and seniority of surgeons were significantly associated with PCR. Medical officers had more PCRs than gazetting specialists (P=0.0000), who inturn had more PCRs than specialists (P=0.000). Each type of cataract surgery done was also significantly associated with PCR-phacoemulsification (phaco), phaco convert to extracapsular cataract extraction (ECCE) and intracapsular cataract extraction (ICCE) (P=0.000), lens aspiration (P=0.020), and ECCE (P=0.003). Specialists got good outcomes compared to trainees without PCR occurring (P=0.001) and also with PCR occurring (P=0.013). However, no difference was observed in the occurrence of PCR in complicated cases between specialists and trainees. Vision was compromised mainly by astigmatism following PCR. Impaired vision (P=0.000) and poor vision (P=0.000) were more than good vision. Poor vision was more in PCR compared to other complications.(P=0.000). CONCLUSION: PCR occurs in all types of cataract surgeries and is the main intraoperative complication causing poor vision. Good outcomes were significantly more when specialists got PCR compared to trainees. Junior surgeons should practice in wet labs and be given more cases. Copyright 2016 by the IJO Press.
    Matched MeSH terms: Lens, Crystalline
  10. Choong YY, Lim KS
    Med J Malaysia, 2001 Mar;56(1):92-4.
    PMID: 11503304
    Phenothiazines have been associated with various ocular adverse effects, in particular cataract and corneal deposits. Several effects are vision threatening. Awareness of these effects, in particular by Psychiatrists and Ophthalmologist, is essential for prompt diagnosis and appropriate treatment. We report two patients presented to us with corneal deposits and lenticular opacities following long term use of Phenothiazines.
    Matched MeSH terms: Lens, Crystalline/drug effects; Lens, Crystalline/metabolism
  11. Thevi T, Reddy SC, Shantakumar C
    Malays Fam Physician, 2014;9(2):41-7.
    PMID: 25883764 MyJurnal
    The aim of the study was to compare the outcomes of phacoemulsification (Phaco) and extracapsular cataract extraction (ECCE) in a district hospital setting.
    Matched MeSH terms: Lens, Crystalline
  12. Lim CZ, Sonny Teo KS, Tai E
    Cureus, 2018 Apr 30;10(4):e2553.
    PMID: 29974009 DOI: 10.7759/cureus.2553
    Cataract, defined as cloudiness of the lens, is a common adverse effect of first-generation antipsychotic medications. Newer generation antipsychotics, also known as atypical antipsychotics, are less commonly associated with cataract. A 19-year-old girl with underlying schizophrenia on olanzapine for the past two years complained of gradual blurring of vision in both eyes for four months prior to presentation. On examination, the best corrected visual acuity was counting finger in both eyes. The anterior segment examination showed bilateral diffuse cortical cataract precluding fundus examination. Systemic examination was unremarkable. Blood investigations revealed a high random blood sugar, which normalised after she was initiated on oral hypoglycemic medication. After bilateral lens aspiration, her visual acuity was 6/6 bilaterally. Olanzapine may be cataractogenic via its action as a serotonin antagonist, which results in reduced glucose responsiveness of the pancreatic beta-cells. Patients on anti-psychotic medication are at risk of developing diabetes mellitus and cataract compared to the general population. Screening for diabetes mellitus should be part of the follow-up of these patients. Ophthalmological evaluation is warranted in the presence of visual complaints.
    Matched MeSH terms: Lens, Crystalline
  13. Hamid SA, Rahman NHA, Yamada Y, Hung PV, Quoc DN
    Sensors (Basel), 2020 Oct 07;20(19).
    PMID: 33036419 DOI: 10.3390/s20195703
    Narrow beam width, higher gain and multibeam characteristics are demanded in 5G technology. Array antennas that are utilized in the existing mobile base stations have many drawbacks when operating at upper 5G frequency bands. For example, due to the high frequency operation, the antenna elements become smaller and thus, in order to provide higher gain, more antenna elements and arrays are required, which will cause the feeding network design to be more complex. The lens antenna is one of the potential candidates to replace the current structure in mobile base station. Therefore, a negative refractive index shaped lens is proposed to provide high gain and narrow beamwidth using energy conservation and Abbe's sine principle. The aim of this study is to investigate the multibeam characteristics of a negative refractive index shaped lens in mobile base station applications. In this paper, the feed positions for the multibeam are selected on the circle from the center of the lens and the accuracy of the feed position is validated through Electromagnetic (EM) simulation. Based on the analysis performed in this study, a negative refractive index shaped lens with a smaller radius and slender lens than the conventional lens is designed, with the additional capability of performing wide-angle beam scanning.
    Matched MeSH terms: Lens, Crystalline
  14. Ansarudin F, Abd Rahman T, Yamada Y, Rahman NHA, Kamardin K
    Sensors (Basel), 2020 Oct 16;20(20).
    PMID: 33081110 DOI: 10.3390/s20205849
    In the 5G mobile system, new features such as millimetre wave operation, small cell size and multi beam are requested at base stations. At millimetre wave, the base station antennas become very small in size, which is about 30 cm; thus, dielectric lens antennas that have excellent multi beam radiation pattern performance are suitable candidates. For base station application, the lens antennas with small thickness and small curvature are requested for light weight and ease of installation. In this paper, a new lens shaping method for thin and small lens curvature is proposed. In order to develop the thin lens antenna, comparisons of antenna structures with conventional aperture distribution lens and Abbe's sine lens are made. Moreover, multi beam radiation pattern of three types of lenses are compared. As a result, the thin and small curvature of the proposed lens and an excellent multi beam radiation pattern are ensured.
    Matched MeSH terms: Lens, Crystalline
  15. Syafruddin SE, Ling S, Low TY, Mohtar MA
    Biomolecules, 2021 Mar 31;11(4).
    PMID: 33807297 DOI: 10.3390/biom11040523
    Cells encounter a myriad of endogenous and exogenous stresses that could perturb cellular physiological processes. Therefore, cells are equipped with several adaptive and stress-response machinery to overcome and survive these insults. One such machinery is the heat shock response (HSR) program that is governed by the heat shock factors (HSFs) family in response towards elevated temperature, free radicals, oxidants, and heavy metals. HSF4 is a member of this HSFs family that could exist in two predominant isoforms, either the transcriptional repressor HSFa or transcriptional activator HSF4b. HSF4 is constitutively active due to the lack of oligomerization negative regulator domain. HSF4 has been demonstrated to play roles in several physiological processes and not only limited to regulating the classical heat shock- or stress-responsive transcriptional programs. In this review, we will revisit and delineate the recent updates on HSF4 molecular properties. We also comprehensively discuss the roles of HSF4 in health and diseases, particularly in lens cell development, cataract formation, and cancer pathogenesis. Finally, we will posit the potential direction of HSF4 future research that could enhance our knowledge on HSF4 molecular networks as well as physiological and pathophysiological functions.
    Matched MeSH terms: Lens, Crystalline/cytology; Lens, Crystalline/metabolism
  16. Agarwal R, Iezhitsa IN, Agarwal P, Spasov AA
    Magnes Res, 2013 Jan-Feb;26(1):2-8.
    PMID: 23708888 DOI: 10.1684/mrh.2013.0336
    Senile cataract is the most common cause of bilateral blindness and results from the loss of transparency of the lens. Maintenance of the unique tissue architecture of the lens is vital for keeping the lens transparent. Membrane transport mechanisms utilizing several magnesium (Mg)-dependent ATPases, play an important role in maintaining lens homeostasis. Therefore, in Mg-deficiency states, ATPase dysfunctions lead to intracellular depletion of K(+) and accumulation of Na(+) and Ca(2+). High intracellular Ca(2+) causes activation of the enzyme calpain II, which leads to the denaturation of crystallin, the soluble lens protein required for maintaining the transparency of the lens. Mg deficiency also interferes with ATPase functions by causing cellular ATP depletion. Furthermore, Mg deficiency enhances lenticular oxidative stress by increased production of free radicals and depletion of antioxidant defenses. Therefore, Mg supplementation may be of therapeutic value in preventing the onset and progression of cataracts in conditions associated with Mg deficiency.
    Matched MeSH terms: Lens, Crystalline/pathology
  17. Iezhitsa I, Agarwal R, Saad SD, Zakaria FK, Agarwal P, Krasilnikova A, et al.
    Mol Vis, 2016;22:734-47.
    PMID: 27440992
    PURPOSE: Increased lenticular oxidative stress and altered calcium/magnesium (Ca/Mg) homeostasis underlie cataractogenesis. We developed a liposomal formulation of magnesium taurate (MgT) and studied its effects on Ca/Mg homeostasis and lenticular oxidative and nitrosative stress in galactose-fed rats.

    METHODS: The galactose-fed rats were topically treated with liposomal MgT (LMgT), liposomal taurine (LTau), or corresponding vehicles twice daily for 28 days with weekly anterior segment imaging. At the end of the experimental period, the lenses were removed and subjected to analysis for oxidative and nitrosative stress, Ca and Mg levels, ATP content, Ca(2+)-ATPase, Na(+),K(+)-ATPase, and calpain II activities.

    RESULTS: The LTau and LMgT groups showed significantly lower opacity index values at all time points compared to the corresponding vehicle groups (p<0.001). However, the opacity index in the LMgT group was lower than that in the LTau group (p<0.05). Significantly reduced oxidative and nitrosative stress was observed in the LTau and LMgT groups. The lens Ca/Mg ratio in LMgT group was decreased by 1.15 times compared to that in the LVh group. Calpain II activity in the LMgT group was decreased by 13% compared to the LVh group. The ATP level and Na(+),K(+)-ATPase and Ca(2+)-ATPase activities were significantly increased in the LMgT group compared to the LVh group (p<0.05).

    CONCLUSIONS: Topical liposomal MgT delays cataractogenesis in galactose-fed rats by maintaining the lens mineral homeostasis and reducing lenticular oxidative and nitrosative stress.

    Matched MeSH terms: Lens, Crystalline/drug effects; Lens, Crystalline/metabolism
  18. Agarwal R, Iezhitsa I, Agarwal P, Spasov A
    Exp Eye Res, 2012 Aug;101:82-9.
    PMID: 22668657 DOI: 10.1016/j.exer.2012.05.008
    Magnesium is one of the most important regulatory cation involved in several biological processes. It is important for maintaining the structural and functional integrity of vital ocular tissues such as lens. Presence of high magnesium content especially in the peripheral part of lens as compared to aqueous and vitreous humor has been observed. Magnesium plays significant role as a cofactor for more than 350 enzymes in the body especially those utilizing ATP. Membrane associated ATPase functions that are crucial in regulating the intracellular ionic environment, are magnesium-dependent. Moreover, the enzymes involved in ATP production and hydrolysis are also magnesium-dependent. Magnesium deficiency by interfering with ATPase functions causes increased intracellular calcium and sodium and decreases intracellular potassium concentration. Furthermore, magnesium deficiency is associated with increased oxidative stress secondary to increased expression of inducible nitric oxide synthase and increased production of nitric oxide. Thus the alterations in lenticular redox status and ionic imbalances form the basis of the association of magnesium deficiency with cataract. In this paper we review the mechanisms involved in magnesium homeostasis and the role of magnesium deficiency in the pathogenesis of cataract.
    Matched MeSH terms: Lens, Crystalline/metabolism
  19. Bariah Mohd Ali, Goh, E.H.
    MyJurnal
    The objective of this study was to determine the efficiency of UV blocking monomers in contact lenses in providing eye protection from UV radiation. The spectral transmission of 8 contact lenses (7 soft contact lenses: Precision UV, Acuvue 2, Surevue, Omega, Encore UV, Durasoft 3 and Lunelle UV and 1 rigid gas permeable contact lens: Boston 7) was evaluated by using a dual beam spectrophotometer. Durasoft 3, a non UV absorbent contact lens was used as the control. The results showed that Precision UV contact lens absorbed UV light up to wavelength of 380 nm, whereas Acuvue 2 and Surevue absorbed up to 360 nm only. Omega, Encore UV and Lunelle UV lenses absorbed UV light up to 335 nm with spectral transmission of Lunelle UV being the highest among all soft contact lenses tested, which was 17%. Boston 7 could absorb UV light up to 385 nm, but the amount of UV light transmitted was higher than soft lenses, which was 30%. Durasoft 3 only blocked UV light at 200-245 nm. Precision UV lens had better UV blocker characteristics than the other contact lenses tested. UV blocking soft contact lenses could be an alternative for spectacles in protecting internal ocular structures from UV radiation.
    Matched MeSH terms: Lens, Crystalline
  20. Azhany Y, Norhayati A, Siti Raihan I, Liza Sharmini AT
    Malays Fam Physician, 2014;9(2):48-52.
    PMID: 25883765 MyJurnal
    To determine the clinical presentations, management and outcome of lens-induced glaucoma (LIG) in Hospital Universiti Sains Malaysia.
    Matched MeSH terms: Lens, Crystalline
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links