Displaying publications 81 - 100 of 658 in total

Abstract:
Sort:
  1. Hoe, S.Z., Pendek, R., Lam, S.K., Rahim, Z.H.A.
    Ann Dent, 1997;4(1):-.
    MyJurnal
    Human saliva contains a large number of proteins which can be separated using polyacrylamide gel electrophoresis (PAGE). In this study the protein profiles of whole saliva of diabetic and non-diabetic were compared. Considerable variations between individuals in the protein profiles were observed. The saliva from diabetic patients appeared to have more of proline-rich protein bands in the molecular weight region below 56 KOa. Further investigations using individual gland saliva should be carried out.
    Matched MeSH terms: Electrophoresis, Polyacrylamide Gel
  2. Mohd Rosni, S., Fisal, A., Azwan, A., Chye, F. Y., Matanjun, P.
    MyJurnal
    It is crucial to determine several protein-related parameters at the initial stages of proteomic analysis of any biological samples. In this study, crude protein content, total soluble protein, total phenolic content and the SDS-PAGE profile of fifteen varieties of seaweed from Semporna, Sabah, Malaysia were analysed. The crude protein, total soluble protein and total phenolic content of all seaweed samples were in the range of 3.99 to 13.18 % of dry weight, 0.52 to 1.45 mg/mL in acetone dried powder samples and 8.59 to 48.98 mg PGE/g dry weight, respectively. In general, the differences (crude protein, total soluble protein and total phenolic content) among all fifteen varieties of seaweeds were significant (p< 0.05). There was also a strong positive correlation between crude protein and total soluble protein concentration (Pearson’s Correlation Coefficient (r)=0.923; p=0.01) in these fifteen varieties of seaweed. A distinctive protein pattern was observed in the SDS-PAGE gels between three different seaweed classes of green, red and brown colours. All of these results are important in sample preparations (extractions) before furthering proteomic analysis in order to identify and characterize seaweed proteomes.
    Matched MeSH terms: Electrophoresis, Polyacrylamide Gel
  3. Che Engku Noramalina Che-Engku-Chik, Siti Sarah Othman, Helmi Wasoh, Nor Azah Yusof, Jaafar Abdullah, Mohd Hazani Mat Zaid
    MyJurnal
    Despite the continued effort globally made to control the growing case of Tuberculosis (TB), it
    continues to be regarded as the second deadliest disease after the HIV. There are various
    methods developed to diagnose TB, most of which having the criteria of sensitive, selective,
    cheap and portable to be used in robust applications. Even with the advancement in medication,
    the important keys including early stage diagnosis is yet to be considered. In diagnosing TB, the
    only technique remained as the gold standard method is the culturing method, which is the Acid
    Fast Bacilli (AFB) staining. On the other hand, molecular technique utilising Polymerase Chain
    Reaction (PCR) assay is preferred as a non-culturing method. Additionally, as molecular
    techniques become advanced, real-time PCR or quantitative PCR (qPCR) using multiple probes
    in one shot has raised interest among researchers, because it can skip the process of gel
    electrophoresis. Recently, researchers have been working on electrochemical DNA sensors
    which are sensitive, selective, rapid, cheap and can meet with point of care (POC) testing
    requirements to diagnose TB.
    Matched MeSH terms: Electrophoresis
  4. Mohd Fakharul Zaman Raja Yahya, Hasidah Mohd Sidek
    Kajian ini melibatkan pemantauan perkembangan parasitemia dan taburan morfologi Plasmodium berghei sewaktu infeksi parasit dalam mencit, serta penentuan kesan infeksi P. berghei ke atas pengisyaratan MAP kinase eritrosit perumah. Analisis mikroskop ke atas slaid calitan darah terwarna-Giemsa yang disediakan daripada mencit terinfeksi-P. berghei (strain PZZ1/00) menunjukkan darjah parasitemia mencapai sehingga 70% dalam masa dua minggu selepas penyuntikan parasit. Morfologi cecincin dan trofozoit parasit dicerap dengan jelas sepanjang tempoh infeksi manakala morfologi skizon parasit hanya dicerap dengan ketara selepas hari ketiga selepas penyuntikan parasit. Pemblotan Western [antibodi primer: anti-MAP kinase (ERK-1/2 tak terfosfat) monoklon; antibodi sekunder: anti-IgG, poliklon terkonjugat-HRP] ke atas protein sitosol eritrosit terinfeksi-P. berghei (70% parasitemia) susulan pemisahan SDS-PAGE menunjukkan bahawa keamatan protein imunoreaktif-MAP kinase eritrosit berberat molekul 42 dan 44 kDa didapati meningkat secara signifikan (p<0.05) pada 70% iaitu peningkatan sebanyak 21.5% dan 22.3% masing-masing berbanding sampel kawalan tanpa infeksi. Samada kesan infeksi P. berghei (70% parasitemia) ke atas pengisyaratan MAP kinase perumah ini berkaitan dengan pengaktifan enzim ini perlu dikaji dengan lebih lanjut.
    Matched MeSH terms: Electrophoresis, Polyacrylamide Gel
  5. Rasli, H.I., Sarbon, N.M.
    MyJurnal
    Enzymatic hydrolysis of proteins is an important bioprocess method to prepare bioactive peptides with many functionality and health benefits. The aims of the present work were to prepare and determine the physicochemical characteristics of gelatine hydrolysate from skin of shortfin scad (SSGH) via hydrolysis using alcalase. Analyses on chemical composition, molecular weight by SDS PAGE, protein concentration, amino acid composition, Fourier Transform Infrared Spectroscopic features, and solubility of SSGH were thus performed. The yield of SSGH obtained was 51.01% (d.b.). The chemical compositions of SSGH for moisture, protein, fat, and ash were 13.82%, 90.05%, 1.95%, and 12.48%, respectively. SSGH showed low molecular weight (
    Matched MeSH terms: Electrophoresis, Polyacrylamide Gel
  6. Semail NF, Abdul Keyon AS, Saad B, Kamaruzaman S, Mohamad Zain NN, Lim V, et al.
    Talanta, 2022 Jan 01;236:122833.
    PMID: 34635223 DOI: 10.1016/j.talanta.2021.122833
    A dynamic pH junction was used in capillary electrophoresis (CE-DAD) to on-line preconcentrate, separate, and determine trace amounts of sulfonamide antibiotics (SAs) in milk and yoghurt samples in this study. A sample matrix with 0.15% acetic acid and 10% methanol (MeOH) at a pH of 4.0, and a background electrolyte (BGE) that contained 35 mM sodium citrate with 10% MeOH at a pH of 8.5, and an acidic barrage of 0.4% acetic acid with 10% MeOH at a pH of 2.5 were utilised to achieve a stacking effect for SAs through a dynamic pH junction. Under optimised conditions, the proposed preconcentration method showed good linearity (30-500 ng/mL, r2 ≥ 0.9940), low limits of detection (LODs) of 4.1-6.3 ng/mL, and acceptable analytes recovery (81.2-106.9%) with relative standard deviations (RSDs) within 5.3-13.7 (n = 9). The limits of quantification (LOQs) were below the maximum residue limit approved by the European Union (EU) in this type of matrices. Sensitivity enhancement factors of up to 129 were reached with the optimised dynamic pH junction using CE with a diode array detector (DAD). The method was used to determine SAs in fresh milk, low-fat milk, full-cream milk, and yoghurt samples.
    Matched MeSH terms: Electrophoresis, Capillary
  7. AbuBakar S
    JUMMEC, 1996;1:21-24.
    The effects of human cytomegalovirus (HCMV) infection on human fibroblast cell genomes were investigated using agarose gel electrophoresis. At selected intervals post-infection (PI), cellular D N A from mock-treated and HCMV-infected cells were prepared in low melting point agarose plugs. Results obtained following electrophoresis of the cellular D N A indicate that HCMV infection did not result in extensive degradation of the cellular DNA, even in samples obtained from cells which showed > 95% cytopathologic effects. High molecular weight DNA (> 23 Kb) comparable to that of the mock-treated samples were noted in a l l HCMV infected DNA samples. Digestion of the DNA samples with restriction endonucleases, EcoR I, Not I, Sfi I, and Nru I, however, resulted in the appearance of smaller DNA fragments (< 23 Kb) in samples obtained on day 3, 4, and 5 PI. Since these DNA bands appeared only in the infected cells, it was likely that these were the HCMV genomic DNA fragments. Findings presented in this study support the notion that the cellular DNA of HCMVinfected cells could remained intact and functiona. KEYWORDS: Cytomegalovirus, chromosomes, DNA, genomes, restriction enzymes
    Matched MeSH terms: Electrophoresis
  8. Jamilah, B., Umi Hartina, M.R., Mat Hashim, D., Sazili, A.Q.
    MyJurnal
    The properties of collagens from Barramundi (Lates calcarifer) skin obtained by acid solubilized (control), pepsin and papain aided extractions were investigated. The yields of collagens (dry weight basis) for acid solubilized, pepsin and papain aided extractions were 8.1, 43.6 and 44.0%, respectively. The collagens were generally colorless although collagens from the enzymes aided-extractions were slightly darker. Based on the e-nose evaluation, the collagens were considered odorless. The pH of all the collagens was in the vicinity of 3; however, those extracted with papain had significantly higher pH. The polypeptide profiles obtained in the SDS-PAGE analysis for pepsin extracted collagen were similar to those of acid solubilized collagens. Papain extracted collagen had distinctly different SDS-PAGE pattern. All the extracted collagens were of type 1 with apparent peptides molecular weight distribution of 37 to 250 kDalton. They had high solubility in pH 2 to 5 and increasing NaCl concentration up to 6%.
    Matched MeSH terms: Electrophoresis, Polyacrylamide Gel
  9. Teoh WK, Salleh FM, Shahir S
    3 Biotech, 2017 Jun;7(2):97.
    PMID: 28560637 DOI: 10.1007/s13205-017-0740-7
    Microbial arsenite oxidation is an essential biogeochemical process whereby more toxic arsenite is oxidized to the less toxic arsenate. Thiomonas strains represent an important arsenite oxidizer found ubiquitous in acid mine drainage. In the present study, the arsenite oxidase gene (aioBA) was cloned from Thiomonas delicata DSM 16361, expressed heterologously in E. coli and purified to homogeneity. The purified recombinant Aio consisted of two subunits with the respective molecular weights of 91 and 21 kDa according to SDS-PAGE. Aio catalysis was optimum at pH 5.5 and 50-55 °C. Aio exhibited stability under acidic conditions (pH 2.5-6). The V max and K m values of the enzyme were found to be 4 µmol min(-1) mg(-1) and 14.2 µM, respectively. SDS and Triton X-100 were found to inhibit the enzyme activity. The homology model of Aio showed correlation with the acidophilic adaptation of the enzyme. This is the first characterization studies of Aio from a species belonging to the Thiomonas genus. The arsenite oxidase was found to be among the acid-tolerant Aio reported to date and has the potential to be used for biosensor and bioremediation applications in acidic environments.
    Matched MeSH terms: Electrophoresis, Polyacrylamide Gel
  10. Yan B, Huang ZA, Yahaya N, Chen DDY
    PMID: 32531643 DOI: 10.1016/j.jchromb.2020.122216
    Enantioselective analysis is critically important in the pharmaceutical and agricultural industries. However, most of the methods reported were developed for the analysis of pure racemates acquired from chemical synthesis or purification. Direct analysis of chiral enantiomers in complex matrices has rarely been reported. This work demonstrated capillary electrophoresis-mass spectrometry (CE-MS) for the enantioselective analysis of botanical drugs for the first time, using a widely used botanical drug, Corydalis Rhizoma, as an example. The method was used for the simultaneous enantioselective analysis of dl-tetrahydropalmatine and (RS)-tetrahydroberberine (canadine) in Corydalis Rhizoma extract. Using (2-hydroxypropyl)-β-cyclodextrin as the chiral selector, a partial filling technique was used to avoid signal suppression and contamination of the MS detector. Post column organic modifier was used to assist with ionization in the flow through microvial CE-MS interface, therefore, organic solvents was not used in the background electrolyte. The completely aqueous background electrolyte contributed to better chiral separations. The CE-MS method established here can directly determine the analytes in their complex matrix without any pre-purification steps, while also offering high sensitivity and low operational costs (including sample, chiral selector and solvent). In the method validation process, good linearity (r > 0.993), sensitivity and accuracy (recoveries within 89.1-110.0%) were demonstrated. The CE-MS technique was shown to be able to provide good selectivity for the simultaneous chiral separation of multiple pairs of enantiomers in complex matrices.
    Matched MeSH terms: Electrophoresis, Capillary
  11. Abdelsalam M, Eissa AE, Chen SC
    J Adv Res, 2015 Mar;6(2):233-8.
    PMID: 25750757 DOI: 10.1016/j.jare.2013.12.003
    Streptococcus dysgalactiae is an emerging pathogen of fish. Clinically, infection is characterized by the development of necrotic lesions at the caudal peduncle of infected fishes. The pathogen has been recently isolated from different fish species in many countries. Twenty S. dysgalactiae isolates collected from Japan, Taiwan, Malaysia and Indonesia were molecularly characterized by biased sinusoidal field gel electrophoresis (BSFGE) using SmaI enzyme, and tuf gene sequencing analysis. DNA sequencing of ten S. dysgalactiae revealed no genetic variation in the tuf amplicons, except for three strains. The restriction patterns of chromosomal DNA measured by BSFGE were differentiated into six distinct types and one subtype among collected strains. To our knowledge, this report gives the first snapshot of S. dysgalactiae isolates collected from different countries that are localized geographically and differed on a multinational level. This genetic unrelatedness among different isolates might suggest a high recombination rate and low genetic stability.
    Matched MeSH terms: Electrophoresis
  12. Wan Ibrahim WA, Arsad SR, Maarof H, Sanagi MM, Aboul-Enein HY
    Chirality, 2015 Mar;27(3):223-7.
    PMID: 25523071 DOI: 10.1002/chir.22416
    This work aimed to develop a chiral separation method of ketoconazole enantiomers using electrokinetic chromatography. The separation was achieved using heptakis (2, 3, 6-tri-O-methyl)-β-cyclodextrin (TMβCD), a commonly used chiral selector (CS), as it is relatively inexpensive and has a low UV absorbance in addition to an anionic surfactant, sodium dodecyl sulfate (SDS). The influence of TMβCD concentration, phosphate buffer concentration, SDS concentration, buffer pH, and applied voltage were investigated. The optimum conditions for chiral separation of ketoconazole was achieved using 10 mM phosphate buffer at pH 2.5 containing 20 mM TMβCD, 5 mM SDS, and 1.0% (v/v) methanol with an applied voltage of 25 kV at 25 °C with a 5-s injection time (hydrodynamic injection). The four ketoconazole stereoisomers were successfully resolved for the first time within 17 min (total analysis time was 28 min including capillary conditioning). The migration time precision of this method was examined to give repeatability and reproducibility with RSDs ≤5.80% (n =3) and RSDs ≤8.88% (n =9), respectively.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  13. Abdul Keyon AS, Guijt RM, Bolch CJ, Breadmore MC
    J Chromatogr A, 2014 Oct 17;1364:295-302.
    PMID: 25223612 DOI: 10.1016/j.chroma.2014.08.074
    The accumulation of paralytic shellfish toxins (PSTs) in contaminated shellfish is a serious health risk making early detection important to improve shellfish safety and biotoxin management. Capillary electrophoresis (CE) has been proven as a high resolution separation technique compatible with miniaturization, making it an attractive choice in the development of portable instrumentation for early, on-site detection of PSTs. In this work, capillary zone electrophoresis (CZE) with capacitively coupled contactless conductivity detector (C(4)D) and UV detection were examined with counter-flow transient isotachophoresis (tITP) to improve the sensitivity and deal with the high conductivity sample matrix. The high sodium concentration in the sample was used as the leading ion while l-alanine was used as the terminating electrolyte (TE) and background electrolyte (BGE) in which the toxins were separated. Careful optimization of the injected sample volume and duration of the counter-flow resulted in limit of detections (LODs) ranging from 74.2 to 1020 ng/mL for tITP-CZE-C(4)D and 141 to 461 ng/mL for tITP-CZE-UV, an 8-97 fold reduction compared to conventional CZE. The LODs were adequate for the analysis of PSTs in shellfish samples close to the regulatory limit. Intra-day and inter-day repeatability values (percentage relative standard deviation, n=3) of tITP-CZE-C(4)D and tITP-CZE-UV methods for both migration time and peak height were in the range of 0.82-11% and 0.76-10%, respectively. The developed method was applied to the analysis of a contaminated mussel sample and validated against an Association of Official Analytical Chemists (AOAC)-approved method for PSTs analysis by high performance liquid chromatography (HPLC) with fluorescence detection (FLD) after pre-column oxidation of the sample. The method presented has potential for incorporation in to field-deployable devices for the early detection of PSTs on-site.
    Matched MeSH terms: Electrophoresis, Capillary/methods
  14. Keyon AS, Guijt RM, Gaspar A, Kazarian AA, Nesterenko PN, Bolch CJ, et al.
    Electrophoresis, 2014 May;35(10):1496-503.
    PMID: 24591173 DOI: 10.1002/elps.201300353
    Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre- or postcolumn oxidation for fluorescence detection (HPLC-FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on-site monitoring. In this study, CE methods were developed for C(4) D, FLD, UV absorption detection, and MS-making this first report of C(4) D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE-UV and CZE-C(4) D methods provide better resolution, selectivity, and separation efficiency compared to CZE-MS and MEKC-FLD. The sensitivity of the CZE-C(4) D and MEKC-FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE-C(4) D and 60.9 to 104 ng/mL for MEKC-FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE-C(4) D and MEKC-FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE-C(4) D method suffered from significant interferences from the shellfish matrix, MEKC-FLD was successfully used for PST screening of a periodate-oxidized mussel sample, with results confirmed by HPLC-FLD. This confirms the potential of MEKC-FLD for screening of PSTs in shellfish samples.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  15. George E, Lai MI, Teh LK, Ramasamy R, Goh EH, Asokan K, et al.
    Med J Malaysia, 2011 Dec;66(5):429-34.
    PMID: 22390095 MyJurnal
    Detection and quantification of Hb subtypes of human blood is integral to presumptive identification of thalassaemias. It has been used in neonatal screening of thalassaemia and Hb variants. The use of discarded red blood cells following processing of the cord blood for stem cells provides readily available diagnostic material for thalassaemia screening. In this study, we determined the range of Hb subtypes in 195 consecutive cord blood samples collected for cord blood banking. The 'cord blood samples' analysed were those of the remaining red blood cells after the cord blood was processed for stem cell storage. Quantification of Hb subtypes by high performance liquid chromatography (HPLC) was done on BioRad Variant II Hb testing system. Only 73 (36.5%) of the samples could be analyzed neat without dilution. With a 1:300 dilution with wash solution the acceptable area as recommended by the manufacturer for reading of a C-gram within the 1 to 3 million ranges were achieved in all. Eighteen (9%) 12 showed classical Hb Barts (y4) prerun peaks were confirmed by Sebia Hydrasys automated Hb gel electrophoresis and quantified by Sebia Capillarys 2 capillary electrophoresis. Only 1 (0.5%) was presumptively identified with HbH disease. Due to the limited number of samples no beta-thalassaemia major, Hb E beta-thalassaemia and Hb Barts hydrops fetalis were found. The HPLC assay was possible at a cost US$ 5 per sample and a turnover time of 10 samples per hour without technical difficulties. This study reports an effective and valuable protocol for thalassaemia screening in red blood cells which would otherwise be discarded during cord blood processing. Cord blood with severe and intermediate forms of thalassaemia can be preselected and not stored.
    Matched MeSH terms: Electrophoresis/methods
  16. Nor A, Zabedah MY, Norsiah MD, Ngu LH, Suhaila AR
    Malays J Pathol, 2010 Jun;32(1):35-42.
    PMID: 20614724
    Mucopolysaccharidoses (MPS) are a group of inherited disorders caused by the deficiency of specific lysosomal enzymes involved in glycosaminoglycans (GAGs) degradation. Currently, there are 11 enzyme deficiencies resulting in seven distinct MPS clinical syndromes and their subtypes. Different MPS syndromes cannot be clearly distinguished clinically due to overlapping signs and symptoms. Measurement of GAGs content in urine and separation of GAGs using high-resolution electrophoresis (HRE) are very useful initial screening tests for isotyping of MPS before specific enzyme diagnostics. In this study, we measured total urinary GAGs by a method using dimethylmethylene blue (DMB), and followed by isolation and separation of GAGs using high resolution electrophoresis (HRE) technique. Of 760 urine samples analyzed, 40 have abnormal GAGs HRE patterns. Thirty-five of these 40 cases have elevated urinary GAGs levels as well. These abnormal HRE patterns could be classified into 4 patterns: Pattern A (elevated DS and HS; suggestive of MPS I, II or VII; 16 cases), Pattern B (elevated HS and CS; suggestive of MPS III; 17 cases), and Pattern C (elevated KS and CS; suggestive of MPS IV, 5 cases), and Pattern D (elevated DS; suggestive of MPS VI; 2 cases). Based on the GAGs HRE pattern and a few discriminating clinical signs, we performed selective enzymatic investigation in 16 cases. In all except one case with MPS VII, the enzymatic diagnosis correlated well with the provisional MPS type as suggested by the abnormal HRE pattern. Our results showed that GAGs HRE is a useful, inexpensive and practical first-line screening test when MPS is suspected clinically, and it provides an important guide to further enzymatic studies on a selective basis.
    Matched MeSH terms: Electrophoresis/methods*
  17. Al Azzam KM, Saad B, Adnan R, Aboul-Enein HY
    Anal Chim Acta, 2010 Aug 3;674(2):249-55.
    PMID: 20678638 DOI: 10.1016/j.aca.2010.06.046
    A capillary electrophoretic method for the separation of the enantiomers of both ofloxacin and ornidazole is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixtures was achieved in less than 16 min with resolution factors Rs=5.45 and 6.28 for ofloxacin and ornidazole enantiomers, respectively. Separation was conducted using a bare fused-silica capillary and a background electrolyte (BGE) of 50 mM H(3)PO(4)-1 M tris solution; pH 1.85; containing 30 mg mL(-1) of sulfated-beta-cyclodextrin (S-beta-CD). The separation was carried out in reversed polarity mode at 25 degrees C, 18 kV, detection wavelength at 230 nm and using hydrodynamic injection for 15 s. Acceptable validation criteria for selectivity, linearity, precision, and accuracy were studied. The limits of detection (LOD) and limits of quantitation (LOQ) of the enantiomers (ofloxacin enantiomer 1 (OF-E1), ofloxacin enantiomer 2 (OF-E2), ornidazole enantiomer 1 (OR-E1) and ornidazole enantiomer 2 (OR-E2)) were (0.52, 0.46, 0.54, 0.89) and (1.59, 1.40, 3.07, 2.70) microg mL(-1), respectively. The proposed method was successfully applied to the assay of enantiomers of both ofloxacin and ornidazole in pharmaceutical formulations. The computational calculations for the enantiomeric inclusion complexes rationalized the reasons for the different migration times between the ofloxacin and ornidazole enantiomers.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  18. Seriramalu R, Pang WW, Jayapalan JJ, Mohamed E, Abdul-Rahman PS, Bustam AZ, et al.
    Electrophoresis, 2010 Jul;31(14):2388-95.
    PMID: 20575108 DOI: 10.1002/elps.201000164
    The use of lectin affinity chromatography prior to 2-DE separation forms an alternative method to unmask the expression of targeted glycoproteins of lower abundance in serum samples. Reduced expression of alpha-2 macroglobulin (AMG) and complement factor B (CFB) was detected in sera of patients with nasopharyngeal carcinoma (NPC) when pooled serum samples of the patients and those of healthy individuals were subjected to affinity isolation using immobilized champedak mannose-binding lectin and analyzed by 2-DE and densitometry. The AMG and CFB spots were not detected in the 2-DE protein profiles when the same pooled serum samples were subjected to albumin and IgG depletion and neither were they detected when the depleted samples were analyzed by western blotting and lectin detection. Together with other acute-phase response proteins that were previously reported to be altered in expression in NPC patients, AMG and CFB may serve as useful complementary biomarkers for NPC.
    Matched MeSH terms: Electrophoresis, Gel, Two-Dimensional/methods
  19. See KL, Elbashir AA, Saad B, Ali AS, Aboul-Enein HY
    Biomed Chromatogr, 2009 Dec;23(12):1283-90.
    PMID: 19488980 DOI: 10.1002/bmc.1251
    A simple, rapid and validated capillary electrophoretic method has been developed for the separation and determination of ofloxacin and ornidazole in pharmaceutical formulations with detection at 230 nm. Optimal conditions for the quantitative separations were investigated. Analysis times shorter than 4 min were obtained using a background electrolyte solution consisting of 25 mmol/L phosphoric acid adjusted with 1 M Tris buffer to pH 8.5, with hydrodynamic injection of 5 s and 20 kV separation voltage. The validation criteria for accuracy, precision, linearity and limits of detection and quantitation were examined and discussed. An excellent linearity was obtained in concentration range 25-250 microg/mL. The detection limits for ofloxacin and ornidazole were 1.03 +/- 0.11 and 1.80 +/- 0.06 microg/mL, respectively. The proposed method has been applied for the analysis of ofloxacin and ornidazole both individually and in a combined dosage tablet formulation. The proposed validated method showed recoveries between 96.16 and 105.23% of the nominal contents.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
  20. See HH, Hauser PC, Ibrahim WA, Sanagi MM
    Electrophoresis, 2010 Jan;31(3):575-82.
    PMID: 20119968 DOI: 10.1002/elps.200900380
    Rapid and direct online preconcentration followed by CE with capacitively coupled contactless conductivity detection (CE-C(4)D) is evaluated as a new approach for the determination of glyphosate, glufosinate (GLUF), and aminophosphonic acid (AMPA) in drinking water. Two online preconcentration techniques, namely large volume sample stacking without polarity switching and field-enhanced sample injection, coupled with CE-C(4)D were successfully developed and optimized. Under optimized conditions, LODs in the range of 0.01-0.1 microM (1.7-11.1 microg/L) and sensitivity enhancements of 48- to 53-fold were achieved with the large volume sample stacking-CE-C(4)D method. By performing the field-enhanced sample injection-CE-C(4)D procedure, excellent LODs down to 0.0005-0.02 microM (0.1-2.2 microg/L) as well as sensitivity enhancements of up to 245- to 1002-fold were obtained. Both techniques showed satisfactory reproducibility with RSDs of peak height of better than 10%. The newly established approaches were successfully applied to the analysis of glyphosate, glufosinate, and aminophosphonic acid in spiked tap drinking water.
    Matched MeSH terms: Electrophoresis, Capillary/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links