Displaying publications 81 - 100 of 142 in total

Abstract:
Sort:
  1. Khezri R, Hosseini S, Lahiri A, Motlagh SR, Nguyen MT, Yonezawa T, et al.
    Int J Mol Sci, 2020 Oct 02;21(19).
    PMID: 33023274 DOI: 10.3390/ijms21197303
    Zinc-air batteries (ZABs) offer high specific energy and low-cost production. However, rechargeable ZABs suffer from a limited cycle life. This paper reports that potassium persulfate (KPS) additive in an alkaline electrolyte can effectively enhance the performance and electrochemical characteristics of rechargeable zinc-air flow batteries (ZAFBs). Introducing redox additives into electrolytes is an effective approach to promote battery performance. With the addition of 450 ppm KPS, remarkable improvement in anodic currents corresponding to zinc (Zn) dissolution and limited passivation of the Zn surface is observed, thus indicating its strong effect on the redox reaction of Zn. Besides, the addition of 450 ppm KPS reduces the corrosion rate of Zn, enhances surface reactions and decreases the solution resistance. However, excess KPS (900 and 1350 ppm) has a negative effect on rechargeable ZAFBs, which leads to a shorter cycle life and poor cyclability. The rechargeable ZAFB, using 450 ppm KPS, exhibits a highly stable charge/discharge voltage for 800 cycles. Overall, KPS demonstrates great promise for the enhancement of the charge/discharge performance of rechargeable ZABs.
    Matched MeSH terms: Electrolytes/pharmacology; Electrolytes/chemistry*
  2. Khanmirzaei MH, Ramesh S, Ramesh K
    Sci Rep, 2015;5:18056.
    PMID: 26659087 DOI: 10.1038/srep18056
    Gel polymer electrolytes using imidazolium based ionic liquids have attracted much attention in dye-sensitized solar cell applications. Hydroxypropyl cellulose (HPC), sodium iodide (NaI), 1-methyl-3-propylimidazolium iodide (MPII) as ionic liquid (IL), ethylene carbonate (EC) and propylene carbonate (PC) are used for preparation of non-volatile gel polymer electrolyte (GPE) system (HPC:EC:PC:NaI:MPII) for dye-sensitized solar cell (DSSC) applications. The highest ionic conductivity of 7.37 × 10(-3) S cm(-1) is achieved after introducing 100% of MPII with respect to the weight of HPC. Temperature-dependent ionic conductivity of gel polymer electrolytes is studied in this work. XRD patterns of gel polymer electrolytes are studied to confirm complexation between HPC polymer, NaI and MPII. Thermal behavior of the GPEs is studied using simultaneous thermal analyzer (STA) and differential scanning calorimetry (DSC). DSSCs are fabricated using gel polymer electrolytes and J-V centeracteristics of fabricated dye sensitized solar cells were analyzed. The gel polymer electrolyte with 100 wt.% of MPII ionic liquid shows the best performance and energy conversion efficiency of 5.79%, with short-circuit current density, open-circuit voltage and fill factor of 13.73 mA cm(-2), 610 mV and 69.1%, respectively.
    Matched MeSH terms: Electrolytes
  3. Khanmirzaei MH, Ramesh S, Ramesh K
    J Nanosci Nanotechnol, 2020 Apr 01;20(4):2423-2429.
    PMID: 31492257 DOI: 10.1166/jnn.2020.17192
    Solid polymer electrolytes (SPEs) were prepared using rice starch as the polymer, sodium iodide (NaI) as the salt and 1-hexyl-3-methylimidazolium iodide (HMII) as the ionic liquid (IL). The solution casting technique was used for preparation of the PEs. The ionic conductivity and temperaturedependent properties of the PEs were measured and all the SPEs were found to follow the Arrhenius thermal activated model. Ionic conductivity increased as the percentage of ILs increased. The SPE containing 20% (wt) of HMII IL showed the highest ionic conductivity of 1.83×10-3 S/cm. Spectral and structural characterization of the PEs were performed by Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD), respectively. The results of thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) indicate that the decomposition temperature (Tdc), glass transition temperatures (Tg) and melting points (Tm) shifted when complexation with HMII occurred. The PEs were used to fabricate dye-sensitized solar cells (DSSCs) and the DSSCs were analyzed under a 1-sun simulator. The SPE with the highest ionic conductivity displayed a short circuit current density (Jsc) of 9.07 (mA cm-2), open circuit voltage (Voc) of 0.58 (V), a fill factor (FF) of 0.65 and had the highest energy conversion efficiency of 3.42%.
    Matched MeSH terms: Electrolytes
  4. Khalik WF, Ho LN, Ong SA, Voon CH, Wong YS, Yusuf SY, et al.
    Environ Sci Pollut Res Int, 2018 Dec;25(35):35164-35175.
    PMID: 30328543 DOI: 10.1007/s11356-018-3414-z
    The objective of this study was to investigate several operating parameters, such as open circuit, different external resistance, pH, supporting electrolyte, and presence of aeration that might enhance the degradation rate as well as electricity generation of batik wastewater in solar photocatalytic fuel cell (PFC). The optimum degradation of batik wastewater was at pH 9 with external resistor 250 Ω. It was observed that open circuit of PFC showed only 17.2 ± 7.5% of removal efficiency, meanwhile the degradation rate of batik wastewater was enhanced to 31.9 ± 15.0% for closed circuit with external resistor 250 Ω. The decolorization of batik wastewater in the absence of photocatalyst due to the absorption of light irradiation by dye molecules and this process was known as photolysis. The degradation of batik wastewater increased as the external resistor value decreased. In addition, the degradation rate of batik wastewater also increased at pH 9 which was 74.4 ± 34.9% and at pH 3, its degradation rate was reduced to 19.4 ± 8.7%. The presence of aeration and sodium chloride as supporting electrolyte in batik wastewater also affected its degradation and electricity generation. The maximum absorbance of wavelength (λmax) of batik wastewater at 535 nm and chemical oxygen demand gradually decreased as increased in irradiation time; however, batik wastewater required prolonged irradiation time to fully degrade and mineralize in PFC system.
    Matched MeSH terms: Electrolytes
  5. Khalik WF, Ong SA, Ho LN, Wong YS, Voon CH, Yusuf SY, et al.
    Environ Sci Pollut Res Int, 2016 Aug;23(16):16716-21.
    PMID: 27184147 DOI: 10.1007/s11356-016-6840-9
    This study investigated the effect of different supporting electrolyte (Na2SO4, MgSO4, NaCl) in degradation of Reactive Black 5 (RB5) and generation of electricity. Zinc oxide (ZnO) was immobilized onto carbon felt acted as photoanode, while Pt-coated carbon paper as photocathode was placed in a single chamber photocatalytic fuel cell, which then irradiated by UV lamp for 24 h. The degradation and mineralization of RB5 with 0.1 M NaCl rapidly decreased after 24-h irradiation time, followed by MgSO4, Na2SO4 and without electrolyte. The voltage outputs for Na2SO4, MgSO4 and NaCl were 908, 628 and 523 mV, respectively, after 24-h irradiation time; meanwhile, their short-circuit current density, J SC, was 1.3, 1.2 and 1.05 mA cm(-2), respectively. The power densities for Na2SO4, MgSO4 and NaCl were 0.335, 0.256 and 0.245 mW cm(-2), respectively. On the other hand, for without supporting electrolyte, the voltage output and short-circuit current density was 271.6 mV and 0.055 mA cm(-2), respectively. The supporting electrolyte NaCl showed greater performance in degradation of RB5 and generation of electricity due to the formation of superoxide radical anions which enhance the degradation of dye. The mineralization of RB5 with different supporting electrolyte was measured through spectrum analysis and reduction in COD concentration.
    Matched MeSH terms: Electrolytes*
  6. Kadir MF, Aspanut Z, Majid SR, Arof AK
    PMID: 21237698 DOI: 10.1016/j.saa.2010.12.051
    Fourier transform infrared (FTIR) spectroscopy studies of poly(vinyl alcohol) (PVA), and chitosan polymer blend doped with ammonium nitrate (NH(4)NO(3)) salt and plasticized with ethylene carbonate (EC) have been performed with emphasis on the shift of the carboxamide, amine and hydroxyl bands. 1% acetic acid solution was used as the solvent. It is observed from the chitosan film spectrum that evidence of polymer-solvent interaction can be observed from the shifting of the carboxamide band at 1660 cm(-1) and the amine band at 1591 cm(-1) to 1650 and 1557 cm(-1) respectively and the shift of the hydroxyl band from 3377 to 3354 cm(-1). The hydroxyl band in the spectrum of PVA powder is observed at 3354 cm(-1) and is observed at 3343 cm(-1) in the spectrum of the PVA film. On addition of NH(4)NO(3) up to 30 wt.%, the carboxamide, amine and hydroxyl bands shifted from 1650, 1557 and 3354 cm(-1) to 1642, 1541 and 3348 cm(-1) indicating that the chitosan has complexed with the salt. In the PVA-NH(4)NO(3) spectrum, the hydroxyl band has shifted from 3343 to 3272 cm(-1) on addition of salt from 10 to 30 wt.%. EC acts as a plasticizing agent since there is no shift in the bands as observed in the spectrum of PVA-chitosan-EC films. The mechanism of ion migration is proposed for the plasticized and unplasticized PVA-chitosan-NH(4)NO(3) systems. In the spectrum of PVA-chitosan-NH(4)NO(3)-EC complex, the doublet CO stretching in EC is observed in the vicinity 1800 and 1700. This indicates that there is some interaction between the salt and EC.
    Matched MeSH terms: Electrolytes/chemistry*
  7. Johnson RO, Johnson BH, Raman A, Lee EL, Lam KL
    Aust Paediatr J, 1979 Jun;15(2):101-6.
    PMID: 485988
    Matched MeSH terms: Electrolytes/blood
  8. John AS, Sidek MM, Thang LY, Sami S, Tey HY, See HH
    J Chromatogr A, 2021 Feb 08;1638:461868.
    PMID: 33453653 DOI: 10.1016/j.chroma.2020.461868
    One of the major drawbacks of electrophoresis in both capillary and microchip is the unsatisfactory sensitivity. Online sample preconcentration techniques can be regarded as the most common and powerful approaches commonly applied to enhance overall detection sensitivity. While the advances of various online preconcentration strategies in capillary and microchip employing aqueous background electrolytes are well-reviewed, there has been limited discussion of the feasible preconcentration techniques specifically developed for capillary and microchip using nonaqueous background electrolytes. This review provides the first consolidated overview of various online preconcentration techniques in nonaqueous capillary and microchip electrophoresis, covering the period of the last two decades. It covers developments in the field of sample stacking, isotachophoresis, and micellar-based stacking. Attention is also given to multi-stacking strategies that have been used for nonaqueous electrophoresis.
    Matched MeSH terms: Electrolytes/chemistry
  9. Jamilan MA, Abdullah J, Alang Ahmad SA, Md Noh MF
    J Food Sci Technol, 2019 Aug;56(8):3846-3853.
    PMID: 31413410 DOI: 10.1007/s13197-019-03855-x
    In this work, voltammetric study based on cetyltrimethylammonium bromide (CTAB) as an ion-pairing agent for the determination of iodine level in iodized table salt has been explored. CTAB was used as an intermediate compound between iodide (I-) and the electrode due to its ability to dissociate to produce cetyltrimethylammonium ions ([CTA]+). The [CTA]+ with a long hydrophobic alkyl chain can be directly adsorbed onto the surface of the working electrode, and this in turns coated the electrode with cationic charge and enhance the electrode ability to bind to iodide (I-) and other molecular iodine ions. A mixture of iodide and CTAB ([CTA]+I-) was prepared and potential of 1.0 V for 60.0 s was applied to pre-concentrate the solution on the working electrode causing the [CTA]+I- to oxidize to iodine (I2). The produced I2 immediately react with chloride ion (Cl-) from the electrolyte of hydrochloric acid (HCl) to produce I2Cl- and form ion-pair with CTA+ as [CTA]+I2Cl-. The linear calibration curve of the developed method towards iodide was in the concentration range of 0.5-4.0 mg/L with sensitivity of - 1.383 µA mg/L-1 cm-2 (R2 = 0.9950), limit of detection (LOD) of 0.3 mg/L and limit of quantification (LOQ) of 1.0 mg/L, respectively. The proposed method indicates good agreement with the standard method for iodine determination with recovery range from 95.0 to 104.3%. The developed method provided potential application as a portable on-site iodine detector.
    Matched MeSH terms: Electrolytes
  10. Iyngkaran N, Yadav M
    Med J Malaysia, 1995 Jun;50(2):141-4.
    PMID: 7565183
    The relative efficacy and incidence of hypernatremia of a rice starch based low sodium (sodium of 60 mmol/L) oral electrolyte solution was compared to the standard WHO oral rehydration solution (ORS; sodium 90 mmol/L) in 60 infants with non choleragenic acute diarrhoea. Both solutions were found to be equally effective in correcting dehydration as determined by the respective post hydration weight gain which was 150 +/- 175 gms in the rice starch low sodium ORS group and 164 +/- 125 gms in the standard WHO ORS group. However, the mean frequency of stools was greater and the duration of stay longer in the WHO ORS group compared to the rice starch low sodium group. There were 5 cases of hypernatremia in the WHO ORS group as opposed to only one in the rice starch low sodium ORS group. The present study shows that a rice starch low sodium ORS was as effective as the standard WHO ORS and had a lower incidence of hypernatremia in the fluid and electrolyte management of infants with non choleragenic diarrhoea.
    Matched MeSH terms: Electrolytes/administration & dosage; Electrolytes/therapeutic use
  11. Ismail N, Myint K, Khaing SL, Giribabu N, Salleh N
    Mol Biol Rep, 2023 Aug;50(8):6729-6737.
    PMID: 37382776 DOI: 10.1007/s11033-023-08555-6
    BACKGROUND: Unexplained infertility could arise from a defect in the cervix. However, the contribution of abnormal cervical fluid microenvironment to this problem still needs to be identified. Therefore, this study identifies the changes in the cervical fluid microenvironment, i.e., pH, electrolytes and osmolarity as well as expression of ion transporters in the cervix including ENaC, CFTR and AQP in fertile women and in women suffering from primary unexplained infertility.

    METHODS: Fertile women and women with unexplained infertility but having regular 28-day menstrual cycles were chosen in this study, Day-22 serum progesterone levels were determined. In the meantime, serum FSH and LH levels were determined on day 2 while, cervical flushing was performed at day 14 to analyse changes in the cervical fluid pH, osmolarity, Na+ and Cl- levels. Meanwhile, cells retrieved from cervical fluid were subjected to mRNA expression and protein distribution analysis for CFTR, AQP and ENaC by qPCR and immunofluorescence, respectively.

    RESULTS: No significant changes in serum progesterone, FSH and LH levels were observed between the two groups. However, cervical fluid pH, osmolarity, Na+ and Cl- levels were significantly lower in primary unexplained infertile group when compared to fertile group. Expression of CFTR and AQP (AQP 1, AQP 2, AQP 5 and AQP 7) in endocervical cells was lower and expression of β-ENaC was higher in primary unexplained infertile women (p 

    Matched MeSH terms: Electrolytes/metabolism
  12. Hosseini S, Lao-Atiman W, Han SJ, Arpornwichanop A, Yonezawa T, Kheawhom S
    Sci Rep, 2018 Oct 08;8(1):14909.
    PMID: 30297883 DOI: 10.1038/s41598-018-32806-3
    Zinc-air batteries are a promising technology for large-scale electricity storage. However, their practical deployment has been hindered by some issues related to corrosion and passivation of the zinc anode in an alkaline electrolyte. In this work, anionic surfactant sodium dodecyl sulfate (SDS) and nonionic surfactant Pluronic F-127 (P127) are examined their applicability to enhance the battery performances. Pristine zinc granules in 7 M KOH, pristine zinc granules in 0-8 mM SDS/7 M KOH, pristine zinc granules in 0-1000 ppm P127/7 M KOH, and SDS coated zinc granules in 7 M KOH were examined. Cyclic voltammograms, potentiodynamic polarization, and electrochemical impedance spectroscopy confirmed that using 0.2 mM SDS or 100 ppm P127 effectively suppressed the anode corrosion and passivation. Nevertheless, direct coating SDS on the zinc anode showed adverse effects because the thick layer of SDS coating acted as a passivating film and blocked the removal of the anode oxidation product from the zinc surface. Furthermore, the performances of the zinc-air flow batteries were studied. Galvanostatic discharge results indicated that the improvement of discharge capacity and energy density could be sought by the introduction of the surfactants to the KOH electrolyte. The enhancement of specific discharge capacity for 30% and 24% was observed in the electrolyte containing 100 ppm P127 and 0.2 mM SDS, respectively.
    Matched MeSH terms: Electrolytes
  13. Ho, L.-H., Tang, J.Y.H., Mazaitul Akma, S., Mohd Aiman, H., Roslan, A.
    MyJurnal
    The objective of this research is to develop an “energy” snack bar supplying energy and
    electrolytes in one bar by utilizing local Malaysian ingredients. The local ingredients used to make
    this snack bar were banana, glutinous rice flour, and coconut milk. It is a wholesome nutritious
    food for different age groups from adolescents to elderly people. Proximate composition, total
    carbohydrate, energy value, and sensory quality of prototype were determined. The developed
    snack bar contains 13.23% of moisture, 1.13% of ash, 6.36% of crude protein, 22.39% of
    crude fat, 1.16% of crude fibre, 56.89% of total carbohydrate, and 454.51 kcal of energy. The
    “energy” snack bar was highly acceptable with desirable sensory quality by all consumers.
    Matched MeSH terms: Electrolytes
  14. Ho M, Khiew P, Isa D, Tan T, Chiu W, Chia C, et al.
    Sains Malaysiana, 2014;43:885-894.
    In this study, a symmetric supercapacitor has been fabricated by adopting the nanostructured iron oxide (Fe304)-activated carbon (Ac) composite as the core electrode materials. The composite electrodes were prepared via a facile mechanical mixing process and PTFE polymeric solution has been used as the electrode material binder. Structural analysis of the nanocomposite electrodes were characterized by scanning electron microscopy ( sEm) and Brunauer-Emmett-Teller (BET) analysis. The electrochemical performances of the prepared supercapacitor were studied using cyclic voltammetry (cv) and electrochemical impedance spectroscopy (Eis) in 1.0 M Na2S03 and 1.0 M Na2SO4 aqueous solutions, respectively. The experimental results showed that the highest specific capacitance of 43 FIg is achieved with a fairly low Fe304 nanomaterials loading (4 wt. %) in 1 M Na2S03. It is clear that the low concentration of nanostructured Fe304 has improved the capacitive performance of the composite via pseudocapacitance charge storage mechanism as well as the enhancement on the specific surface areas of the electrode. However, further increasing of the Fe304 content in the electrode is found to distort the capacitive performance and deteriorate the specific surface area of the electrode, mainly due to the aggregation of the Fe304 particles within the composite. Additionally, the cv results showed that the Fe3041Ac nanocomposite electrode in Na2S03 electrolyte exhibits a better charge storage performance if compared with Na2SO4 solution. It is believed that Fe304 nanoparticles can provide favourable surface adsorption sites for sulphite (S032-) anions which act as catalysts for subsequent redox and intercalation reactions.
    Matched MeSH terms: Electrolytes
  15. Hassan MH, Hassan WMNW, Zaini RHM, Shukeri WFWM, Abidin HZ, Eu CS
    Malays J Med Sci, 2017 Oct;24(5):83-93.
    PMID: 29386975 MyJurnal DOI: 10.21315/mjms2017.24.5.9
    Background: Normal saline (NS) is a common fluid of choice in neurosurgery and neuro-intensive care unit (ICU), but it does not contain other electrolytes and has the potential to cause hyperchloremic metabolic acidosis with prolonged infusion. These problems may be reduced with the availability of balanced fluid (BF), which becomes a more physiological isotonic solution with the presence of complete electrolyte content. This study aimed to compare the changes in electrolytes and acid-base between NS and BF (Sterofundin® ISO) therapy for post-operative severe traumatic brain injury (TBI) patients in neuro-ICU.

    Methods: Sixty-six severe TBI patients who required emergency craniotomy or craniectomy and were planned for post-operative ventilation were randomised into NS (n = 33) and BF therapy groups (n = 33). The calculation of maintenance fluid given was based on the Holliday-Segar method. The electrolytes and acid-base parameters were assessed at an 8 h interval for 24 h. The data were analysed using repeated measures ANOVA.

    Results: The NS group showed a significant lower base excess (-3.20 versus -1.35, P = 0.049), lower bicarbonate level (22.03 versus 23.48 mmol/L, P = 0.031), and more hyperchloremia (115.12 versus 111.74 mmol/L, P < 0.001) and hypokalemia (3.36 versus 3.70 mmol/L, P < 0.001) than the BF group at 24 h of therapy. The BF group showed a significantly higher level of calcium (1.97 versus 1.79 mmol/L, P = 0.003) and magnesium (0.94 versus 0.80 mmol/L, P < 0.001) than the NS group at 24 h of fluid therapy. No significant differences were found in pH, pCO2, lactate, and sodium level.

    Conclusion: BF therapy showed better effects in maintaining higher electrolyte parameters and reducing the trend toward hyperchloremic metabolic acidosis than the NS therapy during prolonged fluid therapy for postoperative TBI patients.

    Matched MeSH terms: Electrolytes
  16. Harvey BJ, Thomas W
    Steroids, 2018 05;133:67-74.
    PMID: 29079406 DOI: 10.1016/j.steroids.2017.10.009
    Aldosterone acts through the mineralocorticoid receptor (MR) to modulate gene expression in target tissues. In the kidney, the principal action of aldosterone is to promote sodium conservation in the distal nephron and so indirectly enhance water conservation under conditions of hypotension. Over the last twenty years the rapid activation of protein kinase signalling cascades by aldosterone has been described in various tissues. This review describes the integration of rapid protein kinase D signalling responses with the non-genomic actions of aldosterone and transcriptional effects of MR activation.
    Matched MeSH terms: Electrolytes/metabolism*
  17. Hamsan MH, Nofal MM, Aziz SB, Brza MA, Dannoun EMA, Murad AR, et al.
    Polymers (Basel), 2021 Apr 11;13(8).
    PMID: 33920346 DOI: 10.3390/polym13081233
    Chitosan (CS)-dextran (DN) biopolymer electrolytes doped with ammonium iodide (NH4I) and plasticized with glycerol (GL), then dispersed with Zn(II)-metal complex were fabricated for energy device application. The CS:DN:NH4I:Zn(II)-complex was plasticized with various amounts of GL and the impact of used metal complex and GL on the properties of the formed electrolyte were investigated.The electrochemical impedance spectroscopy (EIS) measurements have shown that the highest conductivity for the plasticized system was 3.44 × 10-4 S/cm. From the x-ray diffraction (XRD) measurements, the plasticized electrolyte with minimum degree of crystallinity has shown the maximum conductivity. The effect of (GL) plasticizer on the film morphology was studied using FESEM. It has been confirmed via transference number analysis (TNM) that the transport mechanism in the prepared electrolyte is predominantly ionic in nature with a high transference number of ion (ti)of 0.983. From a linear sweep voltammetry (LSV) study, the electrolyte was found to be electrochemically constant as the voltage sweeps linearly up to 1.25 V. The cyclic voltammetry (CV) curve covered most of the area of the current-potential plot with no redox peaks and the sweep rate was found to be affecting the capacitance. The electric double-layer capacitor (EDLC) has shown a great performance of specific capacitance (108.3 F/g), ESR(47.8 ohm), energy density (12.2 W/kg) and power density (1743.4 W/kg) for complete 100 cycles at a current density of 0.5 mA cm-2.
    Matched MeSH terms: Electrolytes
  18. Hamid MAA, Aziz HA, Yusoff MS, Rezan SA
    Water Environ Res, 2021 Apr;93(4):596-607.
    PMID: 32991022 DOI: 10.1002/wer.1461
    The high-strength leachate produced from sanitary landfill is a serious issue around the world as it poses adverse effects on aquatic life and human health. Physio-chemical technology is one of the promising options as the leachate normally presents in stabilized form and not fully amendable by biological treatment. In this research, the effectiveness of natural zeolite (clinoptilolite) augmented electrocoagulation process (hybrid system) for removing high-strength ammonia (3,442 mg/L) and color (8,427 Pt-Co) from naturally saline (15 ppt) local landfill leachate was investigated. A batch mode laboratory-scale reactor with parallel-monopolar aluminum electrodes attached to a direct current (DC) electric power was used as an electrocoagulation reactor for performance enhancement purpose. Optimum operational conditions of 146 g/L zeolite dosage, 600 A/m2 current density, 60 min treatment time, 200 rpm stirring speed, 35 min settling duration, and pH 9 were recorded with up to 70% and 88% removals of ammonia and color, respectively. The estimated overall operational cost was 26.22 $/m3 . The biodegradability of the leachate had improved from 0.05 to 0.27 in all post-treatment processes. The findings revealed the ability of the hybrid process as a viable option in eliminating concentrated ammonia and color in natural saline landfill leachate. PRACTITIONER POINTS: Clinoptilolite was augmented on the electrocoagulation process in saline and stabilized landfill leachate (15 ppt). The high strength NH3 -N (3,442 mg/L) and color (8,427 Pt-Co) were 70% and 88% removed, respectively. The optimum conditions occurred at 140 g/L zeolite, 60 mA/cm2 current density, 60 min, and final pH of 8.20. The biodegradability of the leachate improved from 0.05 to 0.27 after the treatment. This hybrid treatment was simple, faster, and did not require auxiliary electrolyte.
    Matched MeSH terms: Electrolytes
  19. Hafizah M, Liu CY, Ooi JS
    J Neurosurg Sci, 2017 Jun;61(3):263-270.
    PMID: 25854455 DOI: 10.23736/S0390-5616.16.03221-5
    BACKGROUND: This prospective, randomized controlled study compared the changes in acid-base balance and serum electrolytes with the use of intravenous balanced and non-balanced crystalloid solutions intraoperatively during elective neurosurgery.

    METHODS: Thirty consented adult patients who underwent craniotomy were randomly allocated into two groups of 15 patients each. The non-balanced group received 0.9% normal saline while the balanced group received Sterofundin®ISO as the intraoperative fluid for maintenance. Biochemical indices for acid-base balance and serum electrolytes were analyzed periodically.

    RESULTS: In the non-balanced group, significant changes were noted in the pH, base excess and bicarbonate values over time compared to its respective baseline values (P<0.01). Four patients (27.7%) also developed a pH<7.35 and 5 patients (33.3%) developed marked acidosis with base excess

    Matched MeSH terms: Electrolytes/blood*
  20. Giribabu N, Karim K, Kilari EK, Salleh N
    J Ethnopharmacol, 2017 Jun 09;205:123-137.
    PMID: 28483637 DOI: 10.1016/j.jep.2017.05.002
    ETHNOPHARMACOLOGICAL RELEVANCE: Phylanthus niruri has been used to treat ailments related to the urogenital organs. In this study, this herb was hypothesized to help to ameliorate kidney disease in diabetes mellitus (DM).

    AIMS: To investigate P. niruri leaves aqueous extract (PN) effects on kidney functions, histopathological changes and levels of oxidative stress, inflammation, fibrosis, apoptosis and proliferation in DM.

    METHODS: PN was orally administered to streptozotocin-nicotinamide-induced male diabetic rats for 28 days. At the end of the treatment, fasting blood glucose (FBG) and kidney functions were measured. Kidney somatic index, histopathological changes and levels of RAGE, Nrf2, oxidative stress markers (TBARS, SOD, CAT and GPx), inflammatory markers (NFkβ-p65, Ikk-β, TNF-α, IL-1β and IL-6), apoptosis markers (caspase-3, caspase-9 and Bax), fibrosis markers (TGF-β1, VEGF and FGF-1) and proliferative markers (PCNA and Ki-67) were determined by biochemical assays, qPCR, Western blotting, immunohistochemistry or immunofluorescence.

    RESULTS: Administration of PN helps to maintain near normal FBG, creatinine clearance (CCr), blood urea nitrogen (BUN), BUN/Cr ratio, serum electrolytes, uric acid and urine protein levels in DM. Decreased RAGE, TBARS and increased Nrf2, SOD-1, CAT and GPx-1 were observed in PN-treated diabetic rat kidneys. Expression of inflammatory, fibrosis and apoptosis markers in the kidney reduced but expression of proliferative markers increased following PN treatment. Lesser histopathological changes were observed in the kidney of PN-treated diabetic rats.

    CONCLUSION: PN helps to preserve near normal kidney function and prevents histopathological changes via ameliorating oxidative stress, inflammation, fibrosis and apoptosis while enhancing proliferation of the kidney in DM.

    Matched MeSH terms: Electrolytes
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links