Displaying publications 1 - 20 of 65 in total

Abstract:
Sort:
  1. Feng Z, Lim HN, Ibrahim I, Gowthaman NSK
    J Mater Chem B, 2023 Oct 06;11(38):9099-9127.
    PMID: 37650588 DOI: 10.1039/d3tb01221b
    Small biomolecules play a critical role in the fundamental processes that sustain life and are essential for the proper functioning of the human body. The detection of small biomolecules has garnered significant interest in various fields, including disease diagnosis and medicine. Electrochemical techniques are commonly employed in the detection of critical biomolecules through the principle of redox reactions. It is also a very convenient, cheap, simple, fast, and accurate measurement method in analytical chemistry. Zeolitic imidazolate frameworks (ZIFs) are a unique type of metal-organic framework (MOF) composed of porous crystals with extended three-dimensional structures. These frameworks are made up of metal ions and imidazolate linkers, which form a highly porous and stable structure. In addition to their many advantages in other applications, ZIFs have emerged as promising candidates for electrochemical sensors. Their large surface area, pore diameter, and stability make them ideal for use in sensing applications, particularly in the detection of small molecules and ions. This review summarizes the critical role of small biomolecules in the human body, the standard features of electrochemical analysis, and the utilization of various types of ZIF materials (including carbon composites, metal-based composites, ZIF polymer materials, and ZIF-derived materials) for the detection of important small biomolecules in human body fluids. Lastly, we provide an overview of the current status, challenges, and future outlook for research on ZIF materials.
    Matched MeSH terms: Body Fluids*
  2. Verma RK, Pandey M, Chawla P, Choudhury H, Mayuren J, Bhattamisra SK, et al.
    PMID: 33982657 DOI: 10.2174/1871527320666210512014505
    BACKGROUND: The complication of Alzheimer's disease (AD) has made the development of its therapeutic a challenging task. Even after decades of research, we have achieved no more than a few years of symptomatic relief. The inability to diagnose the disease early is the foremost hurdle behind its treatment. Several studies have aimed to identify potential biomarkers that can be detected in body fluids (CSF, blood, urine, etc) or assessed by neuroimaging (i.e., PET and MRI). However, the clinical implementation of these biomarkers is incomplete as they cannot be validated.

    METHOD: To overcome the limitation, the use of artificial intelligence along with technical tools has been extensively investigated for AD diagnosis. For developing a promising artificial intelligence strategy that can diagnose AD early, it is critical to supervise neuropsychological outcomes and imaging-based readouts with a proper clinical review.

    CONCLUSION: Profound knowledge, a large data pool, and detailed investigations are required for the successful implementation of this tool. This review will enlighten various aspects of early diagnosis of AD using artificial intelligence.

    Matched MeSH terms: Body Fluids
  3. Tan PPS, Hall D, Chilian WM, Chia YC, Mohd Zain S, Lim HM, et al.
    Am J Physiol Heart Circ Physiol, 2021 04 01;320(4):H1486-H1497.
    PMID: 33577433 DOI: 10.1152/ajpheart.00888.2020
    MicroRNAs (miRNAs) are small regulatory molecules that are involved in posttranscriptional modifications. These noncoding RNAs are usually ferried by extracellular carriers such as exosomes or other protein and lipid carriers inside a range of body fluids including plasma and urine. Due to their ability to withstand harsh external conditions, exosomal miRNAs possess enormous potential as noninvasive disease biomarkers for, notably hypertension, whereby exosomal miRNAs have been implicated in its pathophysiological processes. More importantly, alterations in the microenvironment as a result of disease progression can induce active and selective loading of miRNAs into exosomes. In this paper, we first review the mechanisms of miRNA loading into exosomes, followed by the roles of exosomal miRNAs in the development of hypertension, and the potentials of exosomal miRNAs as biomarkers in comparison with other free circulating miRNAs. Finally, challenges and future research surrounding exosomal miRNAs will also be discussed. This review will aid in the understanding of noninvasive biomarkers for the early diagnosis of hypertension and for probing therapeutic efficacy.
    Matched MeSH terms: Body Fluids
  4. Kathiravelu Z, Thambiah SC, Mat Salleh MJ, Samsudin IN
    Malays J Pathol, 2021 Apr;43(1):101-107.
    PMID: 33903313
    INTRODUCTION: Haemolytic specimens are a frequent occurrence in clinical laboratories, and they interfere with the analysis of many tests.

    CASE REPORT: We describe here an unusual case of leptospirosis complicated by haemolytic anaemia in a 70-year-old man with established kidney failure. He presented with an abrupt onset of shortness of breath, flushing and erythematous rash after completing haemodialysis. The patient's biochemistry test samples were however rejected twice as they were grossly haemolysed. The integrated auto-verification alert system implemented in the hospital's laboratory information system alerted the staff of the possibility of in vivo haemolysis.

    DISCUSSION: The auto-verification alert system effectively distinguishes between in vitro and in vivo haemolysis and as such can be utilised as a diagnostic aid in patients with suspected intravascular haemolysis.

    Matched MeSH terms: Body Fluids
  5. Kamarulzaman MN, Chik A, Ghazali H
    Malays Fam Physician, 2021 Mar 25;16(1):114-116.
    PMID: 33948149 DOI: 10.51866/cr1016
    Background: A penile median raphe cyst is an uncommon congenital lesion that is formed due to failure of the median raphe to close completely during embryo development. The majority of the cysts are asymptomatic and often go unnoticed. Here, we report acute urinary retention as a very rare complication of a penile median raphe cyst.

    Case presentation: A 21-year-old single man presented with a sudden onset of acute urinary retention of one days' duration. Urethral catheterization was done at the Emergency Department and this drained 800 ml of urine. On further questioning, he claimed that he had had a painless nodule at the glans penis since childhood. The swelling increased in size in the past week causing discomfort. He denied any history of genitalia trauma or recent sexual intercourse. On examination, there was a bluish lesion over the ventral aspect of the glans penis measuring about 3 x 2 cm. The lesion was later excised and histopathology revealed a median raphe cyst of the penis.

    Conclusion: A penile median raphe cyst is a rare lesion. Acute urinary retention caused by this lesion is very rare.

    Matched MeSH terms: Body Fluids
  6. Tey HY, See HH
    J Chromatogr A, 2021 Jan 04;1635:461731.
    PMID: 33285415 DOI: 10.1016/j.chroma.2020.461731
    Conventional sampling of biological fluids often involves a bulk quantity of samples that are tedious to collect, deliver and process. Miniaturized sampling approaches have emerged as promising tools for sample collection due to numerous advantages such as minute sample size, patient friendliness and ease of shipment. This article reviews the applications and advances of microsampling techniques in therapeutic drug monitoring (TDM), covering the period January 2015 - August 2020. As whole blood is the gold standard sampling matrix for TDM, this article comprehensively highlights the most historical microsampling technique, the dried blood spot (DBS), and its development. Advanced developments of DBS, ranging from various automation DBS, paper spray mass spectrometry (PS-MS), 3D dried blood spheroids and volumetric absorptive paper disc (VAPD) and mini-disc (VAPDmini) are discussed. The volumetric absorptive microsampling (VAMS) approach, which overcomes the hematocrit effect associated with the DBS sample, has been employed in recent TDM. The sample collection and sample preparation details in DBS and VAMS are outlined and summarized. This review also delineates the involvement of other biological fluids (plasma, urine, breast milk and saliva) and their miniaturized dried matrix forms in TDM. Specific features and challenges of each microsampling technique are identified and comparison studies are reviewed.
    Matched MeSH terms: Body Fluids
  7. C W Ahmad CWI, Awang Lukman K, Raja Omar RM, Jeffree MS
    Risk Manag Healthc Policy, 2021;14:803-808.
    PMID: 33658876 DOI: 10.2147/RMHP.S278786
    Background and Aim: Healthcare workers (HCWs) routinely experience occupational blood and body fluid exposure (OBBE), including percutaneous injury and splash exposure to non-intact skin. The objective of this study was to determine the prevalence of OBBE and identify associated risk factors.

    Methods: A cross-sectional study was performed on 334 HCWs at 9 workstations. Data were collected with a self-administered questionnaire that consisted of four parts: sociodemographic variables, work-related information, knowledge about needle stick and sharps injury and splash exposure, and information regarding previous OBBE incidents. The data were analyzed by SPSS version 22.0 software.

    Findings: The prevalence of OBBE was 25.1% (95% confidence interval: 20.6-30.2), mostly due to percutaneous injuries, which were not reported to authorities. The highest proportions were among nurses and those working in the medical ward. Needle recapping practices were associated with almost a four-times higher risk of OBBE compared to no-recapping practices. HCWs who did not have any infection prevention training had a three-times higher risk of OBBE.

    Conclusion: Factors associated with OBBE are unsafe work practices, inadequate infection prevention training, and lack of knowledge regarding blood-borne infection. There is a need for more training and increased awareness about the risks of OBBE to reduce unsafe practices.

    Matched MeSH terms: Body Fluids
  8. Mansor AF, Azmi AI, Zain MZM, Jamaluddin R
    Heliyon, 2020 Aug;6(8):e04812.
    PMID: 32913911 DOI: 10.1016/j.heliyon.2020.e04812
    Nickel-titanium shape memory alloy (NiTi) has a unique capacity to restore its initial shape after deformation, which is highly applicable to orthopaedic implantations, especially for the minimization of invasive surgeries. The high nickel content of this alloy can lead to unfavourable effects on the human body upon dissolution; thus, a reliable barrier of coatings on the NiTi surface is required to alleviate the nickel migration and increase its biocompatibility. In this paper, analyses of a titanium oxide layer development on NiTi surface using electrical discharge coating (EDC) process is presented. The recast layer thickness, crater sizes, and surface roughness were characterized based on five parameters; polarity, discharge duration, pulse interval, peak current, and gap voltage. The results show that the discharge duration is the most significant parameter to influence all responses, followed by peak current. The surface characteristics of the EDC substrate is depending on the crater formations and is highly correlated with the discharge energy intensity. As a result, appropriate parametric conditions of the electrical discharge coating process can enhance the NiTi surface for future medical applications, without compromising the shape memory effect.
    Matched MeSH terms: Body Fluids
  9. Amjad M, Badshah S, Rafique AF, Adil Khattak M, Khan RU, Abdullah Harasani WI
    Materials (Basel), 2020 May 16;13(10).
    PMID: 32429420 DOI: 10.3390/ma13102299
    Implants are widely used in the human body for the replacement of affected bones. Fatigue failure is one of the serious concerns for implants. Therefore, understanding of the underlying mechanism leading to fatigue failure is important for the longevity of biomaterial implants. In this paper, the fracture toughness and fatigue crack growth of titanium alloy biomaterial Ti-27Nb has been experimentally investigated. The Ti-27Nb material is tested for fatigue crack growth in different environmental conditions representing the ambient and in vitro environments for 504 hours and 816 hours, respectively. Fractography of the tested specimen is conducted using Scanning Electron Microscope (SEM). The results of the fatigue crack growth propagation of the ambient and in vitro samples are similar in the Paris crack growth region. However, in the threshold region, the crack growth rate is higher for the Simulated Body Fluid (SBF) treated specimen. The fracture surface morphology of in vitro samples shows brittle fracture as compared to ambient specimens with significant plasticity and striations marks. It is proposed that a similar investigation may be conducted with specimens treated in SBF for prolonged periods to further ascertain the findings of this study.
    Matched MeSH terms: Body Fluids
  10. Norhayaty Sharman Khamis @ Roslee, Mohd Shaiful Ehsan Shalihin, Iskandar Ibrahim, Zalini Zin
    MyJurnal
    Milk discharge from neonatal breast commonly occurs bilaterally. Majority of them are benign in nature. Those cases usually require conservative management and will resolve with time. It typically occurs within one month of age in which late-onset of galactorrhoea in toddlers is indeed a rare occasion. Thus, an abnormal cause needs to be ruled out. An 18-months-old child had persistent milky discharge from the left nipple for several days without underlying specific identified causes. This case highlights the occurrence of physiological milk discharge can still possibly occur at the age beyond one-year-old despite its absence in the initial months of life. The principle observation at primary care is still adequate in managing such cases unless high suspicion of alarming disease arises. This case proved a late onset of physiological galactorrhoea can still occur in the early toddler age group.
    Matched MeSH terms: Body Fluids
  11. Miyazaki T, Akaike J, Kawashita M, Lim HN
    PMID: 30889741 DOI: 10.1016/j.msec.2019.01.091
    Nanocomposites of magnetite (Fe3O4) and reduced graphene oxide (rGO) generate heat under an alternating magnetic field and therefore have potential applications as thermoseeds for cancer hyperthermia treatment. However, the properties of such nanocomposites as biomaterials have not been sufficiently well characterized. In this study, the osteoconductivity of Fe3O4-rGO nanocomposites of various compositions was evaluated in vitro in terms of their apatite-forming ability in simulated body fluid (SBF). Furthermore, the heat generation of the nanocomposites was measured under an alternating magnetic field. The apatite-forming ability in SBF improved as the Fe3O4 content in the nanocomposite was increased. As the Fe3O4 content was increased, the nanocomposite not only rapidly raised the surrounding temperature to approximately 100 °C, but the specific absorption rate also increased. We assumed that the ionic interaction between the Fe3O4 and rGO was enhanced and that Brown relaxation was suppressed as the proportion of rGO in the nanocomposite was increased. Consequently, a high content of Fe3O4 in the nanocomposite was effective for improving both the osteoconductivity and heat generation characteristics for hyperthermia applications.
    Matched MeSH terms: Body Fluids/chemistry
  12. Ikeda M, Ishima Y, Chuang VTG, Sakai M, Osafune H, Ando H, et al.
    Molecules, 2019 Apr 30;24(9).
    PMID: 31052207 DOI: 10.3390/molecules24091689
    Intracellular polysulfide could regulate the redox balance via its anti-oxidant activity. However, the existence of polysulfide in biological fluids still remains unknown. Recently, we developed a quantitative analytical method for polysulfide and discovered that polysulfide exists in plasma and responds to oxidative stress. In this study, we confirmed the presence of polysulfide in other biological fluids, such as semen and nasal discharge. The levels of polysulfide in these biological fluids from healthy volunteers (n = 9) with identical characteristics were compared. Additionally, the circadian rhythm of plasma polysulfide was also investigated. The polysulfide levels detected from nasal discharge and seminal fluid were approximately 400 and 600 μM, respectively. No correlation could be found between plasma polysulfide and the polysulfide levels of tear, saliva, and nasal discharge. On the other hand, seminal polysulfide was positively correlated with plasma polysulfide, and almost all polysulfide contained in semen was found in seminal fluid. Intriguingly, saliva and seminal polysulfide strongly correlated with salivary amylase and sperm activities, respectively. These results provide a foundation for scientific breakthroughs in various research areas like infertility and the digestive system process.
    Matched MeSH terms: Body Fluids
  13. Srinivasan S, Yeri A, Cheah PS, Chung A, Danielson K, De Hoff P, et al.
    Cell, 2019 04 04;177(2):446-462.e16.
    PMID: 30951671 DOI: 10.1016/j.cell.2019.03.024
    Poor reproducibility within and across studies arising from lack of knowledge regarding the performance of extracellular RNA (exRNA) isolation methods has hindered progress in the exRNA field. A systematic comparison of 10 exRNA isolation methods across 5 biofluids revealed marked differences in the complexity and reproducibility of the resulting small RNA-seq profiles. The relative efficiency with which each method accessed different exRNA carrier subclasses was determined by estimating the proportions of extracellular vesicle (EV)-, ribonucleoprotein (RNP)-, and high-density lipoprotein (HDL)-specific miRNA signatures in each profile. An interactive web-based application (miRDaR) was developed to help investigators select the optimal exRNA isolation method for their studies. miRDar provides comparative statistics for all expressed miRNAs or a selected subset of miRNAs in the desired biofluid for each exRNA isolation method and returns a ranked list of exRNA isolation methods prioritized by complexity, expression level, and reproducibility. These results will improve reproducibility and stimulate further progress in exRNA biomarker development.
    Matched MeSH terms: Body Fluids/chemistry
  14. Long CM, Tang K, Chokshi H, Fotaki N
    AAPS PharmSciTech, 2019 Feb 13;20(3):113.
    PMID: 30761437 DOI: 10.1208/s12249-019-1317-z
    The aim of this study is to investigate the dissolution properties of poorly soluble drugs from their pure form and their amorphous formulation under physiological relevant conditions for oral administration based on surface dissolution ultraviolet (UV) imaging. Dissolution of two poorly soluble drugs (cefuroxime axetil and itraconazole) and their amorphous formulations (Zinnat® and Sporanox®) was studied with the Sirius Surface Dissolution Imager (SDI). Media simulating the fasted state conditions (compendial and biorelevant) with sequential media/flow rate change were used. The dissolution mechanism of cefuroxime axetil in simulated gastric fluid (SGF), fasted state simulated gastric fluid (FaSSGF) and simulated intestinal fluid (SIF) is predominantly swelling as opposed to the convective flow in fasted state simulated intestinal fluid (FaSSIF-V1), attributed to the effect of mixed micelles. For the itraconazole compact in biorelevant media, a clear upward diffusion of the dissolved itraconazole into the bulk buffer solution is observed. Dissolution of itraconazole from the Sporanox® compact is affected by the polyethylene glycol (PEG) gelling layer and hydroxypropyl methylcellulose (HPMC) matrix, and a steady diffusional dissolution pattern is revealed. A visual representation and a quantitative assessment of dissolution properties of poorly soluble compounds and their amorphous formulation can be obtained with the use of surface dissolution imaging under in vivo relevant conditions.
    Matched MeSH terms: Body Fluids
  15. Woon YL, Lim MF, Tg Abd Rashid TR, Thayan R, Chidambaram SK, Syed Abdul Rahim SS, et al.
    BMC Infect Dis, 2019 Feb 13;19(1):152.
    PMID: 30760239 DOI: 10.1186/s12879-019-3786-9
    BACKGROUND: A major outbreak of the Zika virus (ZIKV) has been reported in Brazil in 2015. Since then, it spread further to other countries in the Americas and resulted in declaration of the Public Health Emergency of International Concern (PHEIC) by World Health Organization. In 2016, Singapore reported its first minor ZIKV epidemic. Malaysia shares similar ecological environment as Brazil and Singapore which may also favor ZIKV transmission. However, no ZIKV outbreak has been reported in Malaysia to date. This study aimed to discuss all confirmed ZIKV cases captured under Malaysia ZIKV surveillance system after declaration of the PHEIC; and explore why Malaysia did not suffer a similar ZIKV outbreak as the other two countries.

    METHODS: This was an observational study reviewing all confirmed ZIKV cases detected in Malaysia through the ZIKV clinical surveillance and Flavivirus laboratory surveillance between June 2015 and December 2017. All basic demographic characteristics, co-morbidities, clinical, laboratory and outcome data of the confirmed ZIKV cases were collected from the source documents.

    RESULTS: Only eight out of 4043 cases tested positive for ZIKV infection during that period. The median age of infected patients was 48.6 years and majority was Chinese. Two of the subjects were pregnant. The median interval between the onset of disease and the first detection of ZIKV Ribonucleic Acid (RNA) in body fluid was 3 days. Six cases had ZIKV RNA detected in both serum and urine samples. Phylogenetic analysis suggests that isolates from the 7 cases of ZIKV infection came from two clusters, both of which were local circulating strains.

    CONCLUSION: Despite similar ecological background characteristics, Malaysia was not as affected by the recent ZIKV outbreak compared to Brazil and Singapore. This could be related to pre-existing immunity against ZIKV in this population, which developed after the first introduction of the ZIKV in Malaysia decades ago. A serosurvey to determine the seroprevalence of ZIKV in Malaysia was carried out in 2017. The differences in circulating ZIKV strains could be another reason as to why Malaysia seemed to be protected from an outbreak.

    Matched MeSH terms: Body Fluids
  16. Ramli NSK, Giribabu N, Karim K, Salleh N
    J Mol Histol, 2019 Feb;50(1):21-34.
    PMID: 30430402 DOI: 10.1007/s10735-018-9804-1
    Precise regulation of vas deferens fluid volume which is important for sperm survival might be influenced by testosterone. In order to investigate changes in vas deferens fluid volume and aquoporins (AQP) isoforms expression under testosterone influence, orchidectomized Sprague-Dawley rats were given 125 and 250 µg/kg/day testosterone with or without flutamide, an androgen receptor blocker or finasteride, a 5alpha-reductase inhibitor for seven consecutive days. Following treatment completion, vas deferens was perfused and changes in the fluid secretion rate and osmolality were determined in the presence of acetazolamide. Rats were then sacrificed and vas deferens was harvested for histology, tissue expression and distribution analyses of AQP-1, AQP-2, AQP-5, AQP-7 and AQP-9 proteins by Western blotting and immunohistochemistry, respectively. Our findings indicate that testosterone causes vas deferens fluid secretion rate to increase, which was antagonized by acetazolamide. Fluid osmolality increased following testosterone treatment and further increased when acetazolamide was given. Co-administration of flutamide or finasteride with testosterone causing both fluid secretion rate and osmolality to decrease. Histology revealed increased size of vas deferens lumen with increased thickness of vas deferens stroma. Expression of AQP-1, AQP-2 and AQP-9 were detected in vas deferens but not AQP-5 and AQP-7, and the levels of these proteins were increased by testosterone treatment mainly at the apical membrane of vas deferens epithelium. In conclusion, increased in vas deferens fluid secretion rate under testosterone influence mediated via the up-regulation of AQP-1, 2 and 9 might be important for vas deferens fluid homeostasis in order to ensure normal male fertility.
    Matched MeSH terms: Body Fluids/drug effects
  17. Agyei D, Pan S, Acquah C, Bekhit AEA, Danquah MK
    J Food Biochem, 2019 01;43(1):e12482.
    PMID: 31353495 DOI: 10.1111/jfbc.12482
    Peptides with biological properties, that is, bioactive peptides, are a class of biomolecules whose health-promoting properties are increasingly being exploited in food and health products. However, research on targeted techniques for the detection and quantification of these peptides is still in its infancy. Such information is needed in order to enhance the biological and chemometric characterization of peptides and their subsequent application in the functional food and pharmaceutical industries. In this review, the role of classic techniques such as electrophoretic, chromatographic, and peptide mass spectrometry in the structure-informed detection and quantitation of bioactive peptides are discussed. Prospects for the use of aptamers in the characterization of bioactive peptides are also discussed. PRACTICAL APPLICATIONS: Although bioactive peptides have huge potential applications in the functional foods and health area, there are limited techniques in enhancing throughput detection, quantification, and characterization of these peptides. This review discusses state-of-the-art techniques relevant in complementing bioactive detection and profiling irrespective of the small number of amino acid units. Insights into challenges, possible remedies and prevailing areas requiring thorough research in the extant literature for food chemists and biotechnologists are also presented.
    Matched MeSH terms: Body Fluids/chemistry*
  18. Che Wan Ilmiyah Ahmad, Raja Muhammad Raja Omar, Khamisah Awang Lukman
    MyJurnal
    Introduction: Healthcare workers (HCWs) are exposed to occupational blood and body fluid exposure (OBBE) that potentially cause blood-borne infection such as HIV, Hepatitis B and Hepatitis C, with risk of transmission 0.3%, 6 to 30% and 0-10% respectively. They are exposed to these infections through percutaneous injury, splash exposure of blood and body fluids to mucous membrane and non-intact skin. Aim of this study was to determine prevalence and risk factors associated with occupational exposure of blood and body fluid in a tertiary government hospital in Sabah. Methods: A cross sectional study was conducted involving 10 places, was chosen by stratified random sampling and involved various job categories (specialist, medical officer, house officer, nurse, hospital assistant and Sedafiat worker). Self-administered questionnaire used as study tool. The data was analysed by using SPSS version 22.0. Association of risk factors and OBBE incidence were determined by Chi-square test and simple logistic regression. Results: A total of 334 respondents involved in this study. Prevalence of OBBE was 25.2% with 95% CI of 20.6% to 30.2% and highest (41.3%) among HCWs working in medical ward. Nurses were less likely to have occupational exposure to blood and body fluids (Crude OR=0.33, 95% CI: 0.20, 0.57). Needle recapping (Crude OR=3.77, 95% CI: 1.99, 7.10) and never attend training in infection prevention (Crude OR=3.19, 95% CI: 1.69, 6.05) were associ-ated with higher odds of OBBE. There was 76.3% of respondents adhere to universal precaution. HCWs who did not work in shift (Crude OR=3.04, 95% CI: 1.49, 6.21) and non-nurses (Crude OR=2.04, 95% CI: 1.06, 3.92) profession had better adherence to universal precaution. Conclusion: Prevalence of OBBE was 25.2%. Modifiable risk factors for OBBE were identified including needle recapping and training on infection prevention. Shift work is associated with adherence to universal precaution. Adequate training, increasing knowledge and awareness may help to reduce OBBE burden.
    Matched MeSH terms: Body Fluids
  19. Nur Azida Che Lah, Muhamad Hellmy Hussin
    MyJurnal
    Titanium (Ti) and Ti-based alloys presence the most widely applied as advanced biomaterials
    in biomedical implant applications. Moreover, these alloys are known to be the most
    valuable metallic materials including spinal cord surgical treatment. It becomes an interest
    due to its advantages compared to others, including its bio compatibility and corrosion
    resistant. However, an issue arises when it comes for permanent implant application as
    the alloy has a possible toxic effect produced from chemical reaction between body fluid
    environments with alloys chemical compositions. It also relies on the performance of
    neighbouring bone tissue to integrate with the implant surface. Abnormalities usually
    happen when surrounding tissue shows poor responses and rejection of implants that would
    leads to body inflammation. These cause an increase in foreign body reaction leading to
    severe body tissue response and thus, loosening of the implant. Corrosion effects and
    biocompatibility behaviour of implantation usage also become one of the reasons of
    implant damage. Here, this paper reviews the importance of using Ti and Ti-based alloys
    in biomedical implantation, especially in orthopaedic spinal cord injury. It also reviews the
    basic aspects of corrosion effects that lead to implant mechanical damage, poor response
    of body rejection and biocompatibility behaviour of implantation usage.
    Matched MeSH terms: Body Fluids
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links