METHODS: In this study, prior to synthesis, quality control analysis method for 18F-Fluorocholine was developed and validated, by adapting the equipment set-up used in 18F-Fluorodeoxyglucose (18FFDG) routine production. Quality control on the 18F-Fluorocholine was performed by means of pH, radionuclidic identity, radio-high performance liquid chromatography equipped with ultraviolet, radio- thin layer chromatography, gas chromatography and filter integrity test.
RESULTS: Post-synthesis; the pH of 18F-Fluorocholine was 6.42 ± 0.04, with half-life of 109.5 minutes (n = 12). The radiochemical purity was consistently higher than 99%, both in radio-high performance liquid chromatography equipped with ultraviolet (r-HPLC; SCX column, 0.25 M NaH2PO4: acetonitrile) and radio-thin layer chromatography method (r-TLC). The calculated relative retention time (RRT) in r-HPLC was 1.02, whereas the retention factor (Rf) in r-TLC was 0.64. Potential impurities from 18F-Fluorocholine synthesis such as ethanol, acetonitrile, dimethylethanolamine and dibromomethane were determined in gas chromatography. Using our parameters, (capillary column: DB-200, 30 m x 0.53 mm x 1 um) and oven temperature of 35°C (isothermal), all compounds were well resolved and eluted within 3 minutes. Level of ethanol and acetonitrile in 18F-Fluorocholine were detected below threshold limit; less than 5 mg/ml and 0.41 mg/ml respectively. Meanwhile, dimethylethanolamine and dibromomethane were undetectable.
CONCLUSION: A convenient, efficient and reliable quality control analysis work-up procedure for 18FFluorocholine has been established and validated to comply all the release criteria. The convenient method of quality control analysis may provide a guideline to local GMP radiopharmaceutical laboratories to start producing 18F-Fluorocholine as a tracer for prostate cancer imaging.
RESULTS: The adsorption of bovine serum albumin (BSA) onto anion-exchange Q-sepharose solid particulate support was investigated in batch adsorption experiments. Adsorption kinetics and isotherms were developed as a function of key industrially relevant parameters such as polymer loading, stirring speed, buffer pH, protein concentration and the state of protein dispersion (solid/aqueous) in order to optimize binding performance and adsorption capacity. Experimental results showed that the first order rate constant is higher at higher stirring speed, higher polymer loading, and under alkaline conditions, with a corresponding increase in equilibrium adsorption capacity. Increasing the stirring speed and using aqueous dispersion protein system increased the adsorption rate, but the maximum protein adsorption was unaffected. Regardless of the stirring speed, the adsorption capacity of the polymer was 2.8 mg/ml. However, doubling the polymer loading increased the adsorption capacity to 9.4 mg/ml.
CONCLUSIONS: The result demonstrates that there exists a minimum amount of polymer loading required to achieve maximum protein adsorption capacity under specific process conditions.